Coaxwave SMA SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | R&D ATE Aerospace Communications
  • Coaxwave SMA SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | R&D ATE Aerospace Communications
  • 1/1
  • Coaxwave SMA SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | R&D ATE Aerospace Communications

Coaxwave SMA SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | R&D ATE Aerospace Communications

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave SMA SOLT Mechanical Calibration Kit is the core calibration benchmark in RF Test & Measurement, 50Ω characteristic impedance, DC-18GHz. Includes SMA M/F Open, M/F Short, M/F fixed Load, and M-M/F-F/M-F Thru adapters. 100% VNA full-band S-parameter characterized, offset phase measured, DC resistance tested. Ships with independent calibration data manual, dedicated torque wrench, and transit case. Supports complete SOLT calibration on multiport VNAs. The definitive precision standard for R&D labs, ATE, aerospace, and commercial communications.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

The SMA Interface — The Global RF Standard

The SMA connector is the most widely deployed RF interface in the world, rated to 18GHz, with the 1/4-36 UNS coupling thread shared across precision 3.5mm and 2.92mm connectors. This mechanical compatibility enables cross-interface mating while SMA maintains its own 18GHz electrical boundary. Coaxwave achieves 50Ω ±0.5% impedance through passivated stainless-steel outer conductors, gold-plated BeCu center contacts, and laser-trimmed tantalum nitride thin-film load resistors. Every standard is individually characterized on a TRL-calibrated VNA from DC to 18GHz.

Frequency Coverage:

Parameter

Specification

Frequency Range

DC – 18 GHz

Interface

SMA, per MIL-STD-348

Impedance

50Ω ±0.5%

Calibration Method

SOLT (Short-Open-Load-Thru)

All Transfer Models (complete SMA SOLT kit matrix — native standards & adapter-type kits):

No.

Model Name

Standard / Kit Type

Gender

Freq

Notes

1

CW-SOLT-SMA-OM

Open

Male (M)

DC-18GHz

Native, 5th-order polynomial

2

CW-SOLT-SMA-OF

Open

Female (F)

DC-18GHz

Native, 5th-order polynomial

3

CW-SOLT-SMA-SM

Short

Male (M)

DC-18GHz

Native, phase ≤±5°

4

CW-SOLT-SMA-SF

Short

Female (F)

DC-18GHz

Native, phase ≤±5°

5

CW-SOLT-SMA-LM

Fixed Load

Male (M)

DC-18GHz

Native, RL ≥22dB

6

CW-SOLT-SMA-LF

Fixed Load

Female (F)

DC-18GHz

Native, RL ≥22dB

7

CW-SOLT-SMA-TMM

Thru Adapter

M-M

DC-18GHz

Native, air-dielectric

8

CW-SOLT-SMA-TFF

Thru Adapter

F-F

DC-18GHz

Native, air-dielectric

9

CW-SOLT-SMA-TMF

Thru Adapter

M-F

DC-18GHz

Native, gender-changer

10

CW-SOLT-SMA-35

Kit + 3.5mm adapter

M-F

DC-18GHz

Both sides 18GHz rated

11

CW-SOLT-SMA-292

Kit + 2.92mm adapter

M-F

DC-18GHz

Both sides 18GHz+ rated

12

CW-SOLT-SMA-N

Kit + N-Type adapter

M-F

DC-18GHz

N-Type extends to 18GHz

13

CW-SOLT-SMA-BNC

Kit + BNC adapter

M-F

DC-4GHz

BNC-limited

💡 Cross-Interface Adapter Kits (10-13): Each combines the full SMA SOLT standard set with a precision SMA-to-target-interface adapter. This enables calibration of DUTs with a different connector using the SMA VNA ports. Frequency is always bounded by the lower-rated interface. For full-band SOLT on the secondary interface, use the native calibration kit for that interface.

Key Performance (independent Coaxwave test system):

  • Open Offset Phase Polynomial: 5th-order coefficients (C0–C5) provided in factory manual

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz)

  • Load Return Loss: ≥ 22dB (DC-12GHz), ≥ 20dB (12-18GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

Inspection: 100% VNA full-band S11 (Open/Short/Load) and S21 (Thru) sweep + offset phase polynomial extraction + DC resistance verification of load element (≤ 0.1Ω). Each kit ships with an independent calibration data manual — your kit's actual S-parameters, polynomial coefficients, and DC resistance data. Laser-marked serial numbers on every standard. Dedicated torque wrench included.

🎯 Core Positioning: The Universal RF Calibration Standard

The SMA interface is the most recognized and deployed RF connector globally — covering DC to 18GHz across commercial wireless, aerospace, and defense. Coaxwave SMA SOLT kits deliver metrology-grade accuracy with the mechanical robustness of 500+ mating cycles. Every standard is characterized on a TRL-calibrated VNA and delivered with full traceability. This is the calibration reference found in every professional RF lab.

⚡ Complete SOLT Inventory

Every Coaxwave SMA SOLT kit contains:

  • Open (M/F): Precision dielectric-break structure with characterized fringing capacitance. 5th-order offset phase polynomial provided for VNA software entry.

  • Short (M/F): Gold-plated BeCu shorting button. Phase deviation from 180° tightly controlled and individually measured.

  • Fixed Load (M/F): Laser-trimmed TaN thin-film resistor on alumina substrate. Return loss ≥ 20dB across DC-18GHz.

  • Thru Adapters (M-M / F-F / M-F): Air-dielectric passivated stainless-steel bodies. Enable direct Thru between any VNA port gender combination.

  • Dedicated Torque Wrench: Calibrated to 0.9 N·m (8 in-lbs). The correct tool for SMA interfaces.

  • Transit Case: Custom-foam hard case, ESD-safe, stackable.

🔧 Full Native & Adapter-Type Matrix

Native Standards (SMA, DC-18GHz):

  • Opens: Male, Female — each with 5th-order polynomial

  • Shorts: Male, Female — each with phase deviation table

  • Loads: Male, Female — each with S11 magnitude data

  • Thrus: M-M, F-F, M-F — gender-flexible calibration

Adapter-Type Kits (SMA + precision transition):

  • + 3.5mm: DC-18GHz calibration of 3.5mm DUTs (both interfaces support ≥18GHz)

  • + 2.92mm: DC-18GHz calibration of 2.92mm DUTs (both sides rated ≥18GHz)

  • + N-Type: DC-18GHz calibration of N-Type DUTs (N-Type supports up to 18GHz in precision grade)

  • + BNC: DC-4GHz calibration of BNC DUTs (legacy test equipment)

🛡️ Coaxwave Quality Barrier

Every SMA SOLT standard undergoes four mandatory 100% tests:

  1. VNA Full-Band S-Parameter Sweep: S11 for Open/Short/Load from DC to 18GHz. S21 for Thru. Every data point recorded.

  2. Offset Phase Polynomial Extraction (Open): C0–C5 coefficients computed from measured phase deviation.

  3. DC Resistance Verification (Load): 4-wire Kelvin measurement of load DC resistance. Must be ≤ 0.1Ω center-to-ground.

  4. Mechanical Gauge Verification: Mating depth and center conductor position checked against MIL-STD-348 gauge standards using CMM.

No sampling. Each kit ships with an independent calibration data manual — your kit's actual measured data for every standard. Laser-marked serial numbers guarantee full traceability.


Electrical Performance

  • Frequency Range: DC – 18 GHz

  • Impedance: 50Ω ±0.5%

  • Open Return Loss: Reference magnitude ≥ 0.90 (low freq, degrades per polynomial model)

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz)

  • Load Return Loss: ≥ 22dB (DC-12GHz), ≥ 20dB (12-18GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

  • VSWR (Thru): ≤ 1.15 (DC-12GHz), ≤ 1.20 (12-18GHz)

Mechanical Performance

  • Connector Interface: SMA, per MIL-STD-348

  • Mating Cycles: ≥ 500

  • Coupling Torque: 0.9 N·m (8 in-lbs) — dedicated torque wrench included

  • Coupling Thread: 1/4-36 UNS (compatible with 3.5mm and 2.92mm wrenches)

  • Center Contact: Beryllium copper, gold-plated over nickel underplating

  • Thru Construction: Air-dielectric, passivated stainless-steel outer conductor

  • Transit Case: Custom foam insert, hard-shell, ESD-safe

Materials & Structure

  • Housing / Outer Conductor: Passivated stainless steel (SUS303)

  • Inner Conductor: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PTFE (Teflon®) with precision air-gap transition at Open aperture

  • Load Element: Tantalum nitride (TaN) thin-film on alumina, laser-trimmed

  • Short Element: BeCu disc, gold-plated, ≤ 0.005mm flatness

  • Interface Standard: MIL-STD-348 (SMA)

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • SOLT Calibration Procedure:

    • Connect Short to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Open to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Load to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Thru between ports → measure S21

    • Enter Open polynomial coefficients and Short phase data from factory manual


  • Cross-Interface Use:

    • When using adapter-type kits, attach precision adapter to SMA standard

    • Calibrate at the adapter's output interface; frequency bounded by lower-rated side


  • Torque — Critical:

    • 0.9 N·m (8 in-lbs) — use the included dedicated torque wrench

    • SMA shares 1/4-36 UNS thread with 3.5mm and 2.92mm — 3.5mm/2.92mm torque wrenches are mechanically compatible

    • However, always use the Coaxwave-supplied wrench for calibration traceability



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

5G FR1 Sub-6GHz

Full SMA kit (9 pcs)

DC-18GHz, full SOLT

3.3-5GHz base station test

Aerospace Avionics

CW-SOLT-SMA-LM

Fixed load, rugged

X-band radar module test

SatCom C-Band

CW-SOLT-SMA-TMF + Loads

M-F Thru, 500+ cycles

3.7-4.2GHz payload test

Defense Communications

CW-SOLT-SMA-TMM

M-M Thru, DC-18GHz

Tactical radio multiport cal

Legacy BNC Equipment

CW-SOLT-SMA-BNC

+BNC adapter, DC-4GHz

Legacy spectrum analyzer cal

High-Power N-Type Systems

CW-SOLT-SMA-N

+N-Type adapter, DC-18GHz

High-power amplifier test

National Metrology Lab

Full kit, metrology grade

±0.5% Z, 100% characterized

Primary 18GHz standard

University Teaching Lab

CW-SOLT-SMA-BNC

+BNC adapter, DC-4GHz

Educational lab, legacy gear

Multiport VNA (4-port)

Full kit + 3 Thrus

M-M/F-F/M-F gender coverage

4-port full SOLT

Production ATE

CW-SOLT-SMA-TMF + Loads

M-F Thru, 500+ cycles

High-volume RF device test

Standard Matrix & Extensions

  • Native Standards: SMA Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) — 9 items

  • Adapter-Type Kits: +3.5mm, +2.92mm, +N-Type, +BNC — 4 configurations

  • Full Kits: All 9 native standards + torque wrench + case; or native + selected adapter

⚡ Electrical Performance Customization

  • Metrology-Grade Load: Return loss ≥ 25dB (DC-12GHz) for national labs

  • 7th-Order Polynomial Open: Extended polynomial for highest phase accuracy above 15GHz

  • Phase-Matched Standard Pairs: Two Shorts matched to ±0.5° for differential system test

Structural Customization

  • Panel-Mount Load: For semi-permanent calibration reference plane in ATE fixtures

  • Captive Center Contact: For high-vibration production environments

  • Keyed Coupling Nut: Prevents mis-mating in confined test bays

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum computing RF test

  • Hermetically Sealed Load: For pressurized calibration environments

  • Extended Temperature Load: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every standard measured DC-18GHz

  • Independent Calibration Data Manual: Actual S-parameters, polynomial coefficients, DC resistance

  • SN Traceability: Laser-marked unique serial numbers on every standard

  • Torque Wrench Calibration: Included wrench pre-calibrated; recalibration service available

  • Rapid Prototyping: Standard kits 2-3 week shipment; custom 4-6 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • SOLT polynomial entry guidance for Keysight, R&S, Anritsu VNAs

    • SMA handling and cleaning best practices

    • Cross-interface calibration plane management

    • Multiport SOLT sequencing for 4-port+ VNAs


Tip

"There is no perfect standard part, only the most suitable solution."

Standard SOLT Calibration (SMA, DC-18GHz)

  • Full 2-Port SOLT on SMA VNA:
    Use the complete native kit. Connect Short → Open → Load to each port, then Thru between ports. Enter Open 5th-order polynomial coefficients from the factory manual. The VNA computes all 12 error terms. Calibration uncertainty at 18GHz is limited only by the characterized data and connector repeatability.

  • Female-Thru for Reverse-Gender Cables:
    Use CW-SOLT-SMA-TFF when both VNA test cables terminate in male connectors. The F-F Thru provides the through-connection without extra gender-changer adapters.

Cross-Interface Calibration

  • SMA VNA to BNC DUT (DC-4GHz):
    Use CW-SOLT-SMA-BNC. Attach BNC adapter to each SMA standard. Calibrate at the BNC plane. Frequency limited to DC-4GHz by BNC. Enables modern SMA VNAs to accurately test legacy BNC equipment.

  • SMA VNA to N-Type DUT (DC-18GHz):
    Use CW-SOLT-SMA-N. Same workflow, 18GHz upper limit. Ideal for high-power amplifier test where N-Type connectors are standard.

Production ATE

  • High-Volume RF Device Test:
    Use CW-SOLT-SMA-TMF (M-F Thru) + Loads in automated calibration fixtures. 500+ mating cycles support high-throughput production. The M-F Thru eliminates gender-changer adapters in typical ATE cable configurations.

⚠️ Usage Red Lines

  • ⚠️ SMA Torque: 0.9 N·m (8 in-lbs) — Use ONLY the Included Wrench:

    • The SMA coupling thread is 1/4-36 UNS — compatible with 3.5mm and 2.92mm wrenches

    • While 3.5mm/2.92mm torque wrenches are mechanically compatible, always use the Coaxwave-supplied wrench for calibration traceability

    • Over-tightening beyond 0.9 N·m cracks the dielectric or deforms the outer conductor → irreversible 18GHz performance loss


  • SMA/3.5mm/2.92mm Mechanical Compatibility ≠ Electrical Rating:

    • SMA shares 1/4-36 UNS thread with 3.5mm and 2.92mm — they will mechanically mate

    • 3.5mm is rated to 26.5GHz; 2.92mm to 40GHz; SMA only to 18GHz

    • For any measurement above 18GHz, use native 3.5mm or 2.92mm — never SMA


  • ⚠️ Cross-Interface Frequency Boundaries Are Absolute:

    • 3.5mm adapter: DC-18GHz (both sides rated ≥18GHz)

    • 2.92mm adapter: DC-18GHz (both sides rated ≥18GHz)

    • N-Type adapter: DC-18GHz (precision N-Type)

    • BNC adapter: DC-4GHz max

    • For full 18GHz SOLT on a non-SMA DUT, use the native cal kit for that interface


  • Clean the Open Aperture Gently:

    • The SMA Open has an exposed precision gap — contamination changes fringing capacitance

    • Clean only with dry filtered air. No swabs, no solvents

    • Cap when not in use



Coaxwave SMA SOLT Mechanical Calibration Kit · Delivery Commitment

  • Frequency: DC – 18 GHz (full SMA band)

  • Impedance: 50Ω ±0.5%

  • Standards: Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) = 9 items

  • Adapter Kits: 4 cross-interface configurations (+3.5mm, +2.92mm, +N-Type, +BNC)

  • Materials: Passivated stainless steel + BeCu gold-plated contacts + TaN thin-film load

  • 100% VNA Full-Band Characterization + Polynomial Extraction + DC Resistance Test + CMM Gauge + Independent Calibration Data Manual + Dedicated Torque Wrench + SN Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for SMA SOLT Selection:

  1. SMA Is the Global Default — But Know Its Limits: SMA covers DC-18GHz, which handles the vast majority of commercial and aerospace RF. For anything above 18GHz, step up to 3.5mm, 2.92mm, or higher.

  2. The Included Torque Wrench Is Part of the Calibration Standard: An SMA connector tightened to the wrong torque produces a different impedance than the characterized value. The included wrench is pre-calibrated to 0.9 N·m. If lost, contact Coaxwave for a replacement.

  3. Always Enter the Polynomial Data: The 5th-order coefficients in your factory manual are YOUR unit's actual data. Using "ideal open" in your VNA discards this characterization and increases calibration residual error — especially above 12GHz where fringing becomes significant.


There is no perfect standard part, only the most suitable solution.

Coaxwave SMA SOLT Mechanical Calibration Kits are not merely calibration accessories; they are the engineered foundation of accurate RF measurement from DC to 18GHz. We machine every stainless-steel body and characterize every polynomial coefficient with "German precision" and "French engineering logic". With nine native standards, four cross-interface adapter kits, 100% VNA certification, and a dedicated torque wrench in every box, Coaxwave delivers the most suitable SOLT calibration benchmark for your exact R&D, aerospace, communications, and defense requirement.

Sales Email: sales@coaxial-rf.com