Coaxwave 2.4mm SOLT Mechanical Calibration Kit | 50Ω DC-50GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | 5G SatCom Aerospace Defense ATE
  • Coaxwave 2.4mm SOLT Mechanical Calibration Kit | 50Ω DC-50GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | 5G SatCom Aerospace Defense ATE
  • 1/1
  • Coaxwave 2.4mm SOLT Mechanical Calibration Kit | 50Ω DC-50GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | 5G SatCom Aerospace Defense ATE

Coaxwave 2.4mm SOLT Mechanical Calibration Kit | 50Ω DC-50GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | 5G SatCom Aerospace Defense ATE

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 2.4mm SOLT Mechanical Calibration Kit is the core mmWave calibration benchmark in RF Test & Measurement, 50Ω characteristic impedance, DC-50GHz. Includes 2.4mm M/F Open, M/F Short, M/F fixed Load, and M-M/F-F/M-F Thru adapters. 100% VNA full-band S-parameter characterized, offset phase measured, DC resistance tested. Ships with independent calibration data manual, dedicated torque wrench, and wooden transit case. Supports complete SOLT calibration on multiport VNAs. The definitive E-band precision standard for 5G FR2, SatCom, aerospace, and defense test environments.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

The 2.4mm (K-Type Extended) Interface — The E-Band Workhorse

The 2.4mm connector (often referred to as K-Type extended) is rated to 50GHz and shares the same M7×0.75 coupling thread with 1.85mm (V-Type). This mechanical compatibility allows seamless cross-interface calibration when paired with precision adapters. At 50GHz, the air wavelength is approximately 6mm — demanding sub-micron machining tolerances to maintain 50Ω impedance. Coaxwave addresses this through passivated stainless-steel outer conductors, gold-plated BeCu center contacts, and laser-trimmed thin-film load resistors. Every standard is individually characterized on a TRL-calibrated VNA from DC to 50GHz.

Frequency Coverage:

Parameter

Specification

Frequency Range

DC – 50 GHz

Interface

2.4mm (K-Type extended), per IEEE Std 287™-2007

Impedance

50Ω ±0.5%

Calibration Method

SOLT (Short-Open-Load-Thru)

All Transfer Models (complete 2.4mm SOLT kit matrix — native standards & adapter-type kits):

No.

Model Name

Standard / Kit Type

Gender

Freq

Notes

1

CW-SOLT24-OM

Open

Male (M)

DC-50GHz

Native, 5th-order polynomial

2

CW-SOLT24-OF

Open

Female (F)

DC-50GHz

Native, 5th-order polynomial

3

CW-SOLT24-SM

Short

Male (M)

DC-50GHz

Native, phase ≤±5°

4

CW-SOLT24-SF

Short

Female (F)

DC-50GHz

Native, phase ≤±5°

5

CW-SOLT24-LM

Fixed Load

Male (M)

DC-50GHz

Native, RL ≥22dB

6

CW-SOLT24-LF

Fixed Load

Female (F)

DC-50GHz

Native, RL ≥22dB

7

CW-SOLT24-TMM

Thru Adapter

M-M

DC-50GHz

Native, air-dielectric

8

CW-SOLT24-TFF

Thru Adapter

F-F

DC-50GHz

Native, air-dielectric

9

CW-SOLT24-TMF

Thru Adapter

M-F

DC-50GHz

Native, gender-changer

10

CW-SOLT24-185

Kit + 1.85mm adapter

M-F

DC-50GHz

Both sides 50GHz+ rated

11

CW-SOLT24-292

Kit + 2.92mm adapter

M-F

DC-40GHz

2.92mm-limited

12

CW-SOLT24-35

Kit + 3.5mm adapter

M-F

DC-26.5GHz

3.5mm-limited

13

CW-SOLT24-SMA

Kit + SMA adapter

M-F

DC-18GHz

SMA-limited

💡 Cross-Interface Adapter Kits (10-13): Each combines the full 2.4mm SOLT standard set with a precision 2.4mm-to-target-interface adapter. This enables calibration of DUTs with a different connector using the 2.4mm VNA ports. Frequency is always bounded by the lower-rated interface. For full-band SOLT on the secondary interface, use the native calibration kit for that interface.

Key Performance (independent Coaxwave test system):

  • Open Offset Phase Polynomial: 5th-order coefficients (C0–C5) provided in factory manual

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz), ≤ ±5.0° (DC-50GHz)

  • Load Return Loss: ≥ 22dB (DC-40GHz), ≥ 20dB (40-50GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

Inspection: 100% VNA full-band S11 (Open/Short/Load) and S21 (Thru) sweep + offset phase polynomial extraction + DC resistance verification of load element (≤ 0.1Ω). Each kit ships with an independent calibration data manual — your kit's actual S-parameters, polynomial coefficients, and DC resistance data. Laser-marked serial numbers on every standard. Dedicated 2.4mm torque wrench included.

🎯 Core Positioning: The E-Band Precision Standard

The 2.4mm interface is the most widely adopted mmWave connector for E-band applications — extending to 50GHz with excellent mechanical repeatability and 500+ mating cycles. Coaxwave 2.4mm SOLT kits deliver metrology-grade accuracy without the extreme fragility of smaller interfaces. Every standard is machined to micron tolerances, characterized on a TRL-calibrated VNA, and delivered with full traceability. This is the calibration reference for serious 5G, SatCom, and defense engineering.

⚡ Complete SOLT Inventory

Every Coaxwave 2.4mm SOLT kit contains:

  • Open (M/F): Precision dielectric-break structure with characterized fringing capacitance. 5th-order offset phase polynomial provided for VNA software entry.

  • Short (M/F): Gold-plated BeCu shorting button. Phase deviation from 180° tightly controlled and individually measured.

  • Fixed Load (M/F): Laser-trimmed TaN thin-film resistor on alumina substrate. Return loss ≥ 20dB across DC-50GHz.

  • Thru Adapters (M-M / F-F / M-F): Air-dielectric passivated stainless-steel bodies. Enable direct Thru between any VNA port gender combination.

  • Dedicated 2.4mm Torque Wrench: Calibrated to 0.45 N·m (4 in-lbs). The only tool that should ever touch a 2.4mm coupling nut.

  • Wooden Transit Case: Custom-foam hard case, ESD-safe, stackable, premium finish.

🔧 Full Native & Adapter-Type Matrix

Native Standards (2.4mm, DC-50GHz):

  • Opens: Male, Female — each with 5th-order polynomial

  • Shorts: Male, Female — each with phase deviation table

  • Loads: Male, Female — each with S11 magnitude data

  • Thrus: M-M, F-F, M-F — gender-flexible calibration

Adapter-Type Kits (2.4mm + precision transition):

  • + 1.85mm: DC-50GHz calibration of 1.85mm DUTs (both interfaces support ≥50GHz)

  • + 2.92mm: DC-40GHz calibration of 2.92mm DUTs

  • + 3.5mm: DC-26.5GHz calibration of 3.5mm DUTs

  • + SMA: DC-18GHz calibration of SMA DUTs

🛡️ Coaxwave Quality Barrier

Every 2.4mm SOLT standard undergoes four mandatory 100% tests:

  1. VNA Full-Band S-Parameter Sweep: S11 for Open/Short/Load from DC to 50GHz. S21 for Thru. Every data point recorded.

  2. Offset Phase Polynomial Extraction (Open): C0–C5 coefficients computed from measured phase deviation.

  3. DC Resistance Verification (Load): 4-wire Kelvin measurement of load DC resistance. Must be ≤ 0.1Ω center-to-ground.

  4. Mechanical Gauge Verification: Mating depth and center conductor position checked against IEEE 287 gauge standards using CMM.

No sampling. Each kit ships with an independent calibration data manual — your kit's actual measured data for every standard. Laser-marked serial numbers guarantee full traceability.


Electrical Performance

  • Frequency Range: DC – 50 GHz

  • Impedance: 50Ω ±0.5%

  • Open Return Loss: Reference magnitude ≥ 0.90 (low freq, degrades per polynomial model)

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz), ≤ ±5.0° (DC-50GHz)

  • Load Return Loss: ≥ 22dB (DC-40GHz), ≥ 20dB (40-50GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

  • VSWR (Thru): ≤ 1.15 (DC-40GHz), ≤ 1.20 (40-50GHz)

Mechanical Performance

  • Connector Interface: 2.4mm (K-Type extended) per IEEE Std 287™-2007

  • Mating Cycles: ≥ 500

  • Coupling Torque: 0.45 N·m (4 in-lbs) — dedicated 2.4mm torque wrench included

  • Coupling Thread: M7 × 0.75 metric (compatible with 1.85mm wrenches, NOT SMA/3.5mm)

  • Center Contact: Beryllium copper, gold-plated over nickel underplating

  • Thru Construction: Air-dielectric, passivated stainless-steel outer conductor

  • Transit Case: Custom foam insert, wooden hard-shell, ESD-safe

Materials & Structure

  • Housing / Outer Conductor: Passivated stainless steel (SUS303)

  • Inner Conductor: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PEI (Polyetherimide) with precision air-gap transition at Open aperture

  • Load Element: Tantalum nitride (TaN) thin-film on alumina, laser-trimmed

  • Short Element: BeCu disc, gold-plated, ≤ 0.005mm flatness

  • Interface Standard: IEEE Std 287™-2007 (2.4mm)

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • SOLT Calibration Procedure:

    • Connect Short to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Open to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Load to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Thru between ports → measure S21

    • Enter Open polynomial coefficients and Short phase data from factory manual


  • Cross-Interface Use:

    • When using adapter-type kits, attach precision adapter to 2.4mm standard

    • Calibrate at the adapter's output interface; frequency bounded by lower-rated side


  • Torque — Critical:

    • 0.45 N·m (4 in-lbs) — use the included dedicated 2.4mm torque wrench

    • Do NOT use SMA or 3.5mm wrenches — thread pitch differs (1/4-36 UNS vs. M7×0.75)

    • A SMA wrench will cross-thread or crack the 2.4mm coupling nut



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

5G FR2 Base Station R&D

Full 2.4mm kit (9 pcs)

DC-50GHz, full SOLT

24-43.5GHz OTA calibration

SatCom Ka-band HPA

CW-SOLT24-TMF + Loads

M-F Thru, 500+ cycles

HPA production test

Automotive Radar (77GHz)

CW-SOLT24-292

+2.92mm adapter, DC-40GHz

Radar module EOL (40GHz limit)

Defense EW Receiver

CW-SOLT24-TMM

M-M Thru, DC-50GHz

EW system multiport cal

Legacy 3.5mm VNA

CW-SOLT24-35

+3.5mm adapter, DC-26.5GHz

Extend 3.5mm VNA to 50GHz DUT

National Metrology Lab

Full kit, metrology grade

±0.5% Z, 100% characterized

Primary 50GHz standard

University Research

CW-SOLT24-SMA

+SMA adapter, DC-18GHz

Educational lab, mixed interfaces

Multiport VNA (4-port)

Full kit + 3 Thrus

M-M/F-F/M-F gender coverage

4-port full SOLT

Aerospace Flight-Line

CW-SOLT24-LM

Fixed load, rugged

Field-deployable 50GHz test

Production ATE

CW-SOLT24-TMF + Loads

M-F Thru, high cycles

High-volume E-band test

Standard Matrix & Extensions

  • Native Standards: 2.4mm Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) — 9 items

  • Adapter-Type Kits: +1.85mm, +2.92mm, +3.5mm, +SMA — 4 configurations

  • Full Kits: All 9 native standards + torque wrench + wooden case; or native + selected adapter

⚡ Electrical Performance Customization

  • Metrology-Grade Load: Return loss ≥ 25dB (DC-40GHz) for national labs

  • 7th-Order Polynomial Open: Extended polynomial for highest phase accuracy above 40GHz

  • Phase-Matched Standard Pairs: Two Shorts matched to ±0.5° for differential system test

Structural Customization

  • Panel-Mount Load: For semi-permanent calibration reference plane in ATE fixtures

  • Captive Center Contact: For high-vibration production environments

  • Keyed Coupling Nut: Prevents mis-mating in confined test bays

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum computing RF test

  • Hermetically Sealed Load: For pressurized calibration environments

  • Extended Temperature Load: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every standard measured DC-50GHz

  • Independent Calibration Data Manual: Actual S-parameters, polynomial coefficients, DC resistance

  • SN Traceability: Laser-marked unique serial numbers on every standard

  • Torque Wrench Calibration: Included wrench pre-calibrated; recalibration service available

  • Rapid Prototyping: Standard kits 3-4 week shipment; custom 6-8 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • SOLT polynomial entry guidance for Keysight, R&S, Anritsu VNAs

    • 2.4mm handling and cleaning best practices

    • Cross-interface calibration plane management

    • Multiport SOLT sequencing for 4-port+ VNAs


Tip

"There is no perfect standard part, only the most suitable solution."

Standard SOLT Calibration (2.4mm, DC-50GHz)

  • Full 2-Port SOLT on 2.4mm VNA:
    Use the complete native kit. Connect Short → Open → Load to each port, then Thru between ports. Enter Open 5th-order polynomial coefficients from the factory manual. The VNA computes all 12 error terms. Calibration uncertainty at 50GHz is limited only by the characterized data and connector repeatability.

  • Female-Thru for Reverse-Gender Cables:
    Use CW-SOLT24-TFF when both VNA test cables terminate in male connectors. The F-F Thru provides the through-connection without extra gender-changer adapters.

Cross-Interface Calibration

  • 2.4mm VNA to 2.92mm DUT (DC-40GHz):
    Use CW-SOLT24-292. Attach 2.92mm adapter to each 2.4mm standard. Calibrate at the 2.92mm plane. Frequency limited to DC-40GHz by 2.92mm. Enables 50GHz VNAs to accurately test 2.92mm DUTs.

  • 2.4mm VNA to SMA DUT (DC-18GHz):
    Use CW-SOLT24-SMA. Same workflow, 18GHz upper limit. Essential for legacy test equipment integration.

Production ATE

  • High-Volume E-band Device Test:
    Use CW-SOLT24-TMF (M-F Thru) + Loads in automated calibration fixtures. 500+ mating cycles support high-throughput production. The M-F Thru eliminates gender-changer adapters in typical ATE cable configurations.

⚠️ Usage Red Lines

  • ⚠️ 2.4mm Torque: 0.45 N·m (4 in-lbs) — Use ONLY the Included Wrench:

    • The 2.4mm coupling thread is M7×0.75 metric — NOT compatible with SMA/3.5mm wrenches (1/4-36 UNS)

    • A SMA wrench will cross-thread or crack the coupling nut instantly

    • 1.85mm wrenches share the same M7×0.75 thread and 0.45 N·m torque — technically compatible, but always use the Coaxwave-supplied wrench for traceability


  • Never Use SMA/3.5mm Wrenches on 2.4mm:

    • Thread pitch difference: 1/4-36 UNS (SMA/3.5mm) ≠ M7×0.75 (2.4mm/1.85mm)

    • Forcing a SMA wrench will destroy the 2.4mm coupling nut — irreparable at this precision level


  • ⚠️ Cross-Interface Frequency Boundaries Are Absolute:

    • 1.85mm adapter: DC-50GHz (both sides rated ≥50GHz)

    • 2.92mm adapter: DC-40GHz max

    • 3.5mm adapter: DC-26.5GHz max

    • SMA adapter: DC-18GHz max

    • For full 50GHz SOLT on a non-2.4mm DUT, use the native cal kit for that interface


  • Clean the Open Aperture Gently:

    • The 2.4mm Open has an exposed precision gap — contamination changes fringing capacitance

    • Clean only with dry filtered air. No swabs, no solvents

    • Cap when not in use



Coaxwave 2.4mm SOLT Mechanical Calibration Kit · Delivery Commitment

  • Frequency: DC – 50 GHz (full 2.4mm / K-Type extended band)

  • Impedance: 50Ω ±0.5%

  • Standards: Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) = 9 items

  • Adapter Kits: 4 cross-interface configurations (+1.85/+2.92/+3.5/+SMA)

  • Materials: Passivated stainless steel + BeCu gold-plated contacts + TaN thin-film load

  • 100% VNA Full-Band Characterization + Polynomial Extraction + DC Resistance Test + CMM Gauge + Independent Calibration Data Manual + Dedicated Torque Wrench + SN Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for 2.4mm SOLT Selection:

  1. 2.4mm Is the E-Band Sweet Spot: It reaches 50GHz with 500+ mating cycles and robust mechanical life. For 5G FR2, SatCom, and most mmWave applications, 2.4mm delivers the best balance of frequency coverage and durability.

  2. The Included Torque Wrench Is Part of the Calibration Standard: A 2.4mm connector tightened to the wrong torque produces a different impedance than the characterized value. The included wrench is pre-calibrated to 0.45 N·m. If lost, contact Coaxwave for a replacement — do NOT substitute with a SMA wrench.

  3. Always Enter the Polynomial Data: The 5th-order coefficients in your factory manual are YOUR unit's actual data. Using "ideal open" in your VNA discards this characterization and increases calibration residual error — especially above 26.5GHz where fringing becomes significant.


There is no perfect standard part, only the most suitable solution.

Coaxwave 2.4mm SOLT Mechanical Calibration Kits are not merely calibration accessories; they are the engineered foundation of accurate E-band measurement from DC to 50GHz. We machine every stainless-steel body and characterize every polynomial coefficient with "German precision" and "French engineering logic". With nine native standards, four cross-interface adapter kits, 100% VNA certification, and a dedicated torque wrench in every box, Coaxwave delivers the most suitable SOLT calibration benchmark for your exact 5G, SatCom, aerospace, and defense requirement.