Coaxwave 2.92mm SOLT Mechanical Calibration Kit | 50Ω DC-40GHz | M/F Open Short Load Thru | 100% VNA Tested | 8 in-lbs Torque Wrench | SatCom 5G Aerospace Defense ATE
  • Coaxwave 2.92mm SOLT Mechanical Calibration Kit | 50Ω DC-40GHz | M/F Open Short Load Thru | 100% VNA Tested | 8 in-lbs Torque Wrench | SatCom 5G Aerospace Defense ATE
  • 1/1
  • Coaxwave 2.92mm SOLT Mechanical Calibration Kit | 50Ω DC-40GHz | M/F Open Short Load Thru | 100% VNA Tested | 8 in-lbs Torque Wrench | SatCom 5G Aerospace Defense ATE

Coaxwave 2.92mm SOLT Mechanical Calibration Kit | 50Ω DC-40GHz | M/F Open Short Load Thru | 100% VNA Tested | 8 in-lbs Torque Wrench | SatCom 5G Aerospace Defense ATE

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 2.92mm SOLT Mechanical Calibration Kit is the core Ka-band calibration benchmark in RF Test & Measurement, 50Ω characteristic impedance, DC-40GHz. Includes 2.92mm M/F Open, M/F Short, M/F fixed Load, and M-M/F-F/M-F Thru adapters. 100% VNA full-band S-parameter characterized, offset phase measured, DC resistance tested. Ships with independent calibration data manual, dedicated 8 in-lbs torque wrench, and wooden transit case. Supports complete SOLT calibration on multiport VNAs. The definitive K-Type precision standard for SatCom, 5G, aerospace, and defense test environments.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

The 2.92mm (K-Type) Interface — The Ka-Band Industry Standard

The 2.92mm connector (K-Type) is rated to 40GHz and shares the 1/4-36 UNS coupling thread with SMA and 3.5mm connectors — making it mechanically compatible for cross-interface mating while maintaining superior electrical performance to 40GHz. At 40GHz, the air wavelength is approximately 7.5mm. Coaxwave achieves 50Ω ±0.5% impedance through passivated stainless-steel outer conductors, gold-plated BeCu center contacts, and laser-trimmed tantalum nitride thin-film load resistors. Every standard is individually characterized on a TRL-calibrated VNA from DC to 40GHz.

Frequency Coverage:

Parameter

Specification

Frequency Range

DC – 40 GHz

Interface

2.92mm (K-Type), per MIL-STD-348

Impedance

50Ω ±0.5%

Calibration Method

SOLT (Short-Open-Load-Thru)

All Transfer Models (complete 2.92mm SOLT kit matrix — native standards & adapter-type kits):

No.

Model Name

Standard / Kit Type

Gender

Freq

Notes

1

CW-SOLT292-OM

Open

Male (M)

DC-40GHz

Native, 5th-order polynomial

2

CW-SOLT292-OF

Open

Female (F)

DC-40GHz

Native, 5th-order polynomial

3

CW-SOLT292-SM

Short

Male (M)

DC-40GHz

Native, phase ≤±5°

4

CW-SOLT292-SF

Short

Female (F)

DC-40GHz

Native, phase ≤±5°

5

CW-SOLT292-LM

Fixed Load

Male (M)

DC-40GHz

Native, RL ≥22dB

6

CW-SOLT292-LF

Fixed Load

Female (F)

DC-40GHz

Native, RL ≥22dB

7

CW-SOLT292-TMM

Thru Adapter

M-M

DC-40GHz

Native, air-dielectric

8

CW-SOLT292-TFF

Thru Adapter

F-F

DC-40GHz

Native, air-dielectric

9

CW-SOLT292-TMF

Thru Adapter

M-F

DC-40GHz

Native, gender-changer

10

CW-SOLT292-24

Kit + 2.4mm adapter

M-F

DC-40GHz

Both sides 40GHz+ rated

11

CW-SOLT292-185

Kit + 1.85mm adapter

M-F

DC-40GHz

Both sides 40GHz+ rated

12

CW-SOLT292-35

Kit + 3.5mm adapter

M-F

DC-26.5GHz

3.5mm-limited

13

CW-SOLT292-SMA

Kit + SMA adapter

M-F

DC-18GHz

SMA-limited

💡 Cross-Interface Adapter Kits (10-13): Each combines the full 2.92mm SOLT standard set with a precision 2.92mm-to-target-interface adapter. This enables calibration of DUTs with a different connector using the 2.92mm VNA ports. Frequency is always bounded by the lower-rated interface. For full-band SOLT on the secondary interface, use the native calibration kit for that interface.

Key Performance (independent Coaxwave test system):

  • Open Offset Phase Polynomial: 5th-order coefficients (C0–C5) provided in factory manual

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz), ≤ ±5.0° (DC-40GHz)

  • Load Return Loss: ≥ 22dB (DC-26.5GHz), ≥ 20dB (26.5-40GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

Inspection: 100% VNA full-band S11 (Open/Short/Load) and S21 (Thru) sweep + offset phase polynomial extraction + DC resistance verification of load element (≤ 0.1Ω). Each kit ships with an independent calibration data manual — your kit's actual S-parameters, polynomial coefficients, and DC resistance data. Laser-marked serial numbers on every standard. Dedicated 8 in-lbs (0.9 N·m) torque wrench included.

🎯 Core Positioning: The Ka-Band Industry Benchmark

The 2.92mm (K-Type) interface is the most widely deployed mmWave connector for Ka-band applications — covering the full SatCom uplink/downlink and automotive radar bands to 40GHz. Coaxwave 2.92mm SOLT kits deliver metrology-grade accuracy with the mechanical robustness of 500+ mating cycles. Every standard is characterized on a TRL-calibrated VNA and delivered with full traceability. This is the calibration reference that bridges R&D labs and high-volume production floors.

⚡ Complete SOLT Inventory

Every Coaxwave 2.92mm SOLT kit contains:

  • Open (M/F): Precision dielectric-break structure with characterized fringing capacitance. 5th-order offset phase polynomial provided for VNA software entry.

  • Short (M/F): Gold-plated BeCu shorting button. Phase deviation from 180° tightly controlled and individually measured.

  • Fixed Load (M/F): Laser-trimmed TaN thin-film resistor on alumina substrate. Return loss ≥ 20dB across DC-40GHz.

  • Thru Adapters (M-M / F-F / M-F): Air-dielectric passivated stainless-steel bodies. Enable direct Thru between any VNA port gender combination.

  • Dedicated 8 in-lbs Torque Wrench: Calibrated to 0.9 N·m (8 in-lbs). The correct tool for 2.92mm / SMA / 3.5mm interfaces.

  • Wooden Transit Case: Custom-foam hard case, ESD-safe, stackable, premium finish.

🔧 Full Native & Adapter-Type Matrix

Native Standards (2.92mm, DC-40GHz):

  • Opens: Male, Female — each with 5th-order polynomial

  • Shorts: Male, Female — each with phase deviation table

  • Loads: Male, Female — each with S11 magnitude data

  • Thrus: M-M, F-F, M-F — gender-flexible calibration

Adapter-Type Kits (2.92mm + precision transition):

  • + 2.4mm: DC-40GHz calibration of 2.4mm DUTs (both interfaces support ≥40GHz)

  • + 1.85mm: DC-40GHz calibration of 1.85mm DUTs (both sides rated ≥40GHz)

  • + 3.5mm: DC-26.5GHz calibration of 3.5mm DUTs

  • + SMA: DC-18GHz calibration of SMA DUTs

🛡️ Coaxwave Quality Barrier

Every 2.92mm SOLT standard undergoes four mandatory 100% tests:

  1. VNA Full-Band S-Parameter Sweep: S11 for Open/Short/Load from DC to 40GHz. S21 for Thru. Every data point recorded.

  2. Offset Phase Polynomial Extraction (Open): C0–C5 coefficients computed from measured phase deviation.

  3. DC Resistance Verification (Load): 4-wire Kelvin measurement of load DC resistance. Must be ≤ 0.1Ω center-to-ground.

  4. Mechanical Gauge Verification: Mating depth and center conductor position checked against MIL-STD-348 gauge standards using CMM.

No sampling. Each kit ships with an independent calibration data manual — your kit's actual measured data for every standard. Laser-marked serial numbers guarantee full traceability.


Electrical Performance

  • Frequency Range: DC – 40 GHz

  • Impedance: 50Ω ±0.5%

  • Open Return Loss: Reference magnitude ≥ 0.90 (low freq, degrades per polynomial model)

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz), ≤ ±5.0° (DC-40GHz)

  • Load Return Loss: ≥ 22dB (DC-26.5GHz), ≥ 20dB (26.5-40GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

  • VSWR (Thru): ≤ 1.15 (DC-26.5GHz), ≤ 1.20 (26.5-40GHz)

Mechanical Performance

  • Connector Interface: 2.92mm (K-Type) per MIL-STD-348

  • Mating Cycles: ≥ 500

  • Coupling Torque: 0.9 N·m (8 in-lbs) — dedicated 8 in-lbs torque wrench included

  • Coupling Thread: 1/4-36 UNS (compatible with SMA and 3.5mm wrenches)

  • Center Contact: Beryllium copper, gold-plated over nickel underplating

  • Thru Construction: Air-dielectric, passivated stainless-steel outer conductor

  • Transit Case: Custom foam insert, wooden hard-shell, ESD-safe

Materials & Structure

  • Housing / Outer Conductor: Passivated stainless steel (SUS303)

  • Inner Conductor: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PTFE (Teflon®) with precision air-gap transition at Open aperture

  • Load Element: Tantalum nitride (TaN) thin-film on alumina, laser-trimmed

  • Short Element: BeCu disc, gold-plated, ≤ 0.005mm flatness

  • Interface Standard: MIL-STD-348 (2.92mm/K-Type)

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • SOLT Calibration Procedure:

    • Connect Short to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Open to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Load to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Thru between ports → measure S21

    • Enter Open polynomial coefficients and Short phase data from factory manual


  • Cross-Interface Use:

    • When using adapter-type kits, attach precision adapter to 2.92mm standard

    • Calibrate at the adapter's output interface; frequency bounded by lower-rated side


  • Torque — Critical:

    • 0.9 N·m (8 in-lbs) — use the included dedicated 2.92mm torque wrench

    • 2.92mm shares 1/4-36 UNS thread with SMA and 3.5mm — SMA/3.5mm torque wrenches are mechanically compatible

    • However, always use the Coaxwave-supplied wrench for calibration traceability



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

SatCom Ka-band HPA

Full 2.92mm kit (9 pcs)

DC-40GHz, full SOLT

27.5-30GHz uplink test

Automotive Radar (77GHz)

CW-SOLT292-24

+2.4mm adapter, DC-40GHz

Radar module EOL (40GHz limit)

5G FR2 Base Station

CW-SOLT292-35

+3.5mm adapter, DC-26.5GHz

24-28GHz OTA calibration

Defense EW Receiver

CW-SOLT292-TMM

M-M Thru, DC-40GHz

EW system multiport cal

Legacy SMA VNA

CW-SOLT292-SMA

+SMA adapter, DC-18GHz

Extend SMA VNA to 40GHz DUT

National Metrology Lab

Full kit, metrology grade

±0.5% Z, 100% characterized

Primary 40GHz standard

University Research

CW-SOLT292-SMA

+SMA adapter, DC-18GHz

Educational lab, mixed interfaces

Multiport VNA (4-port)

Full kit + 3 Thrus

M-M/F-F/M-F gender coverage

4-port full SOLT

Aerospace Flight-Line

CW-SOLT292-LM

Fixed load, rugged

Field-deployable 40GHz test

Production ATE

CW-SOLT292-TMF + Loads

M-F Thru, 500+ cycles

High-volume Ka-band test

Standard Matrix & Extensions

  • Native Standards: 2.92mm Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) — 9 items

  • Adapter-Type Kits: +2.4mm, +1.85mm, +3.5mm, +SMA — 4 configurations

  • Full Kits: All 9 native standards + torque wrench + wooden case; or native + selected adapter

⚡ Electrical Performance Customization

  • Metrology-Grade Load: Return loss ≥ 25dB (DC-26.5GHz) for national labs

  • 7th-Order Polynomial Open: Extended polynomial for highest phase accuracy above 30GHz

  • Phase-Matched Standard Pairs: Two Shorts matched to ±0.5° for differential system test

Structural Customization

  • Panel-Mount Load: For semi-permanent calibration reference plane in ATE fixtures

  • Captive Center Contact: For high-vibration production environments

  • Keyed Coupling Nut: Prevents mis-mating in confined test bays

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum computing RF test

  • Hermetically Sealed Load: For pressurized calibration environments

  • Extended Temperature Load: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every standard measured DC-40GHz

  • Independent Calibration Data Manual: Actual S-parameters, polynomial coefficients, DC resistance

  • SN Traceability: Laser-marked unique serial numbers on every standard

  • Torque Wrench Calibration: Included wrench pre-calibrated; recalibration service available

  • Rapid Prototyping: Standard kits 3-4 week shipment; custom 6-8 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • SOLT polynomial entry guidance for Keysight, R&S, Anritsu VNAs

    • 2.92mm handling and cleaning best practices

    • Cross-interface calibration plane management

    • Multiport SOLT sequencing for 4-port+ VNAs


Tip

"There is no perfect standard part, only the most suitable solution."

Standard SOLT Calibration (2.92mm, DC-40GHz)

  • Full 2-Port SOLT on 2.92mm VNA:
    Use the complete native kit. Connect Short → Open → Load to each port, then Thru between ports. Enter Open 5th-order polynomial coefficients from the factory manual. The VNA computes all 12 error terms. Calibration uncertainty at 40GHz is limited only by the characterized data and connector repeatability.

  • Female-Thru for Reverse-Gender Cables:
    Use CW-SOLT292-TFF when both VNA test cables terminate in male connectors. The F-F Thru provides the through-connection without extra gender-changer adapters.

Cross-Interface Calibration

  • 2.92mm VNA to SMA DUT (DC-18GHz):
    Use CW-SOLT292-SMA. Attach SMA adapter to each 2.92mm standard. Calibrate at the SMA plane. Frequency limited to DC-18GHz by SMA. Enables 40GHz VNAs to accurately test legacy SMA DUTs.

  • 2.92mm VNA to 3.5mm DUT (DC-26.5GHz):
    Use CW-SOLT292-35. Same workflow, 26.5GHz upper limit.

Production ATE

  • High-Volume Ka-band Device Test:
    Use CW-SOLT292-TMF (M-F Thru) + Loads in automated calibration fixtures. 500+ mating cycles support high-throughput production. The M-F Thru eliminates gender-changer adapters in typical ATE cable configurations.

⚠️ Usage Red Lines

  • ⚠️ 2.92mm Torque: 0.9 N·m (8 in-lbs) — Use ONLY the Included Wrench:

    • The 2.92mm coupling thread is 1/4-36 UNS — compatible with SMA and 3.5mm wrenches

    • While SMA/3.5mm torque wrenches are mechanically compatible, always use the Coaxwave-supplied wrench for calibration traceability

    • Over-tightening beyond 0.9 N·m deforms the outer conductor → irreversible 40GHz performance loss


  • SMA/3.5mm Mechanical Compatibility ≠ Electrical Rating:

    • 2.92mm shares 1/4-36 UNS thread with SMA and 3.5mm — they will mechanically mate

    • SMA and 3.5mm are electrically capped at 18GHz and 26.5GHz respectively

    • For any measurement above 26.5GHz, use native 2.92mm only


  • ⚠️ Cross-Interface Frequency Boundaries Are Absolute:

    • 2.4mm adapter: DC-40GHz (both sides rated ≥40GHz)

    • 1.85mm adapter: DC-40GHz (both sides rated ≥40GHz)

    • 3.5mm adapter: DC-26.5GHz max

    • SMA adapter: DC-18GHz max

    • For full 40GHz SOLT on a non-2.92mm DUT, use the native cal kit for that interface


  • Clean the Open Aperture Gently:

    • The 2.92mm Open has an exposed precision gap — contamination changes fringing capacitance

    • Clean only with dry filtered air. No swabs, no solvents

    • Cap when not in use



Coaxwave 2.92mm SOLT Mechanical Calibration Kit · Delivery Commitment

  • Frequency: DC – 40 GHz (full 2.92mm / K-Type band)

  • Impedance: 50Ω ±0.5%

  • Standards: Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) = 9 items

  • Adapter Kits: 4 cross-interface configurations (+2.4/+1.85/+3.5/+SMA)

  • Materials: Passivated stainless steel + BeCu gold-plated contacts + TaN thin-film load

  • 100% VNA Full-Band Characterization + Polynomial Extraction + DC Resistance Test + CMM Gauge + Independent Calibration Data Manual + Dedicated 8 in-lbs Torque Wrench + SN Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for 2.92mm SOLT Selection:

  1. 2.92mm Is the Perfect Match for WR28 Waveguide: The 2.92mm 40GHz upper limit aligns exactly with the WR28 Ka-band (26.5-40GHz). For waveguide-to-coax test systems, 2.92mm is the most bandwidth-matched coaxial interface — no wasted frequency headroom.

  2. The Included 8 in-lbs Torque Wrench Is Part of the Calibration Standard: A 2.92mm connector tightened to the wrong torque produces a different impedance than the characterized value. The included wrench is pre-calibrated to 0.9 N·m. If lost, contact Coaxwave for a replacement.

  3. Always Enter the Polynomial Data: The 5th-order coefficients in your factory manual are YOUR unit's actual data. Using "ideal open" in your VNA discards this characterization and increases calibration residual error — especially above 26.5GHz where fringing becomes significant.


There is no perfect standard part, only the most suitable solution.

Coaxwave 2.92mm SOLT Mechanical Calibration Kits are not merely calibration accessories; they are the engineered foundation of accurate Ka-band measurement from DC to 40GHz. We machine every stainless-steel body and characterize every polynomial coefficient with "German precision" and "French engineering logic". With nine native standards, four cross-interface adapter kits, 100% VNA certification, and a dedicated torque wrench in every box, Coaxwave delivers the most suitable SOLT calibration benchmark for your exact SatCom, 5G, aerospace, and defense requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com