Coaxwave N-Type SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | Aerospace SatCom ATE High-Power
  • Coaxwave N-Type SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | Aerospace SatCom ATE High-Power
  • 1/1
  • Coaxwave N-Type SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | Aerospace SatCom ATE High-Power

Coaxwave N-Type SOLT Mechanical Calibration Kit | 50Ω DC-18GHz | M/F Open Short Load Thru | 100% VNA Tested | Dedicated Torque Wrench | Aerospace SatCom ATE High-Power

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave N-Type SOLT Mechanical Calibration Kit is the rugged precision benchmark in RF Test & Measurement, 50Ω characteristic impedance, DC-18GHz. Includes N-Type M/F Open, M/F Short, M/F fixed Load, and M-M/F-F/M-F Thru adapters. 100% VNA full-band S-parameter characterized, offset phase measured, DC resistance tested. Ships with independent calibration data manual, dedicated torque wrench, and wooden transit case. Supports complete SOLT calibration on multiport VNAs. The definitive high-power standard for aerospace, SatCom ground stations, and ATE environments.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

The N-Type Interface — The Rugged Industry Standard

The N-Type (AN) connector is the most trusted high-power RF interface in professional test environments, rated to 18GHz in precision grade. Its 5/8-24 UNS threaded coupling provides a robust, repeatable connection capable of handling higher power levels than SMA or 3.5mm. Coaxwave achieves 50Ω ±0.5% impedance through passivated stainless-steel outer conductors, gold-plated BeCu center contacts, and laser-trimmed tantalum nitride thin-film load resistors. Every standard is individually characterized on a TRL-calibrated VNA from DC to 18GHz.

Frequency Coverage:

Parameter

Specification

Frequency Range

DC – 18 GHz

Interface

N-Type (AN), per MIL-STD-348 / IEC 60169-16

Impedance

50Ω ±0.5%

Calibration Method

SOLT (Short-Open-Load-Thru)

All Transfer Models (complete N-Type SOLT kit matrix — native standards & adapter-type kits):

No.

Model Name

Standard / Kit Type

Gender

Freq

Notes

1

CW-SOLT-N-OM

Open

Male (M)

DC-18GHz

Native, 5th-order polynomial

2

CW-SOLT-N-OF

Open

Female (F)

DC-18GHz

Native, 5th-order polynomial

3

CW-SOLT-N-SM

Short

Male (M)

DC-18GHz

Native, phase ≤±5°

4

CW-SOLT-N-SF

Short

Female (F)

DC-18GHz

Native, phase ≤±5°

5

CW-SOLT-N-LM

Fixed Load

Male (M)

DC-18GHz

Native, RL ≥22dB

6

CW-SOLT-N-LF

Fixed Load

Female (F)

DC-18GHz

Native, RL ≥22dB

7

CW-SOLT-N-TMM

Thru Adapter

M-M

DC-18GHz

Native, air-dielectric

8

CW-SOLT-N-TFF

Thru Adapter

F-F

DC-18GHz

Native, air-dielectric

9

CW-SOLT-N-TMF

Thru Adapter

M-F

DC-18GHz

Native, gender-changer

10

CW-SOLT-N-SMA

Kit + SMA adapter

M-F

DC-18GHz

Both sides 18GHz rated

11

CW-SOLT-N-35

Kit + 3.5mm adapter

M-F

DC-18GHz

Both sides 18GHz rated

12

CW-SOLT-N-716

Kit + 7/16 DIN adapter

M-F

DC-7.5GHz

7/16 DIN-limited

13

CW-SOLT-N-BNC

Kit + BNC adapter

M-F

DC-4GHz

BNC-limited

💡 Cross-Interface Adapter Kits (10-13): Each combines the full N-Type SOLT standard set with a precision N-Type-to-target-interface adapter. This enables calibration of DUTs with a different connector using the N-Type VNA ports. Frequency is always bounded by the lower-rated interface. For full-band SOLT on the secondary interface, use the native calibration kit for that interface.

Key Performance (independent Coaxwave test system):

  • Open Offset Phase Polynomial: 5th-order coefficients (C0–C5) provided in factory manual

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz)

  • Load Return Loss: ≥ 22dB (DC-12GHz), ≥ 20dB (12-18GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

Inspection: 100% VNA full-band S11 (Open/Short/Load) and S21 (Thru) sweep + offset phase polynomial extraction + DC resistance verification of load element (≤ 0.1Ω). Each kit ships with an independent calibration data manual — your kit's actual S-parameters, polynomial coefficients, and DC resistance data. Laser-marked serial numbers on every standard. Dedicated N-Type torque wrench included.

🎯 Core Positioning: The Rugged High-Power Standard

The N-Type interface is the most recognized high-power RF connector in professional test — covering DC to 18GHz with superior mechanical robustness and power handling. Coaxwave N-Type SOLT kits deliver metrology-grade accuracy with the mechanical ruggedness required for field-deployable and high-cycle production environments. Every standard is characterized on a TRL-calibrated VNA and delivered with full traceability.

⚡ Complete SOLT Inventory

Every Coaxwave N-Type SOLT kit contains:

  • Open (M/F): Precision dielectric-break structure with characterized fringing capacitance. 5th-order offset phase polynomial provided for VNA software entry.

  • Short (M/F): Gold-plated BeCu shorting button. Phase deviation from 180° tightly controlled and individually measured.

  • Fixed Load (M/F): Laser-trimmed TaN thin-film resistor on alumina substrate. Return loss ≥ 20dB across DC-18GHz.

  • Thru Adapters (M-M / F-F / M-F): Air-dielectric passivated stainless-steel bodies. Enable direct Thru between any VNA port gender combination.

  • Dedicated N-Type Torque Wrench: Calibrated to 1.1–1.3 N·m (10–12 in-lbs). The correct tool for N-Type interfaces.

  • Wooden Transit Case: Custom-foam hard case, ESD-safe, stackable, premium finish.

🔧 Full Native & Adapter-Type Matrix

Native Standards (N-Type, DC-18GHz):

  • Opens: Male, Female — each with 5th-order polynomial

  • Shorts: Male, Female — each with phase deviation table

  • Loads: Male, Female — each with S11 magnitude data

  • Thrus: M-M, F-F, M-F — gender-flexible calibration

Adapter-Type Kits (N-Type + precision transition):

  • + SMA: DC-18GHz calibration of SMA DUTs (both interfaces support ≥18GHz)

  • + 3.5mm: DC-18GHz calibration of 3.5mm DUTs (both sides rated ≥18GHz)

  • + 7/16 DIN: DC-7.5GHz calibration of 7/16 DIN DUTs (high-power base stations)

  • + BNC: DC-4GHz calibration of BNC DUTs (legacy test equipment)

🛡️ Coaxwave Quality Barrier

Every N-Type SOLT standard undergoes four mandatory 100% tests:

  1. VNA Full-Band S-Parameter Sweep: S11 for Open/Short/Load from DC to 18GHz. S21 for Thru. Every data point recorded.

  2. Offset Phase Polynomial Extraction (Open): C0–C5 coefficients computed from measured phase deviation.

  3. DC Resistance Verification (Load): 4-wire Kelvin measurement of load DC resistance. Must be ≤ 0.1Ω center-to-ground.

  4. Mechanical Gauge Verification: Mating depth and center conductor position checked against MIL-STD-348 gauge standards using CMM.

No sampling. Each kit ships with an independent calibration data manual — your kit's actual measured data for every standard. Laser-marked serial numbers guarantee full traceability.


Electrical Performance

  • Frequency Range: DC – 18 GHz

  • Impedance: 50Ω ±0.5%

  • Open Return Loss: Reference magnitude ≥ 0.90 (low freq, degrades per polynomial model)

  • Short Phase Deviation: ≤ ±2.0° (DC-6GHz), ≤ ±3.0° (DC-18GHz)

  • Load Return Loss: ≥ 22dB (DC-12GHz), ≥ 20dB (12-18GHz)

  • Thru Insertion Loss: ≤ 0.05 dB + 0.005 × f(GHz) dB

  • VSWR (Thru): ≤ 1.15 (DC-12GHz), ≤ 1.20 (12-18GHz)

  • Power Handling (Load): 1W average, 100W peak (load dissipation capability)

Mechanical Performance

  • Connector Interface: N-Type (AN), per MIL-STD-348 / IEC 60169-16

  • Mating Cycles: ≥ 500

  • Coupling Torque: 1.1 – 1.3 N·m (10 – 12 in-lbs) — dedicated N-Type torque wrench included

  • Coupling Thread: 5/8-24 UNS (N-Type specific — NOT compatible with SMA/3.5mm wrenches)

  • Center Contact: Beryllium copper, gold-plated over nickel underplating

  • Thru Construction: Air-dielectric, passivated stainless-steel outer conductor

  • Transit Case: Custom foam insert, wooden hard-shell, ESD-safe

Materials & Structure

  • Housing / Outer Conductor: Passivated stainless steel (SUS303)

  • Inner Conductor: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PTFE (Teflon®) with precision air-gap transition at Open aperture

  • Load Element: Tantalum nitride (TaN) thin-film on alumina, laser-trimmed

  • Short Element: BeCu disc, gold-plated, ≤ 0.005mm flatness

  • Interface Standard: MIL-STD-348 (N-Type)

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • SOLT Calibration Procedure:

    • Connect Short to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Open to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Load to Port 1 → measure S11; then Port 2 → measure S11

    • Connect Thru between ports → measure S21

    • Enter Open polynomial coefficients and Short phase data from factory manual


  • Cross-Interface Use:

    • When using adapter-type kits, attach precision adapter to N-Type standard

    • Calibrate at the adapter's output interface; frequency bounded by lower-rated side


  • Torque — Critical:

    • 1.1 – 1.3 N·m (10 – 12 in-lbs) — use the included dedicated N-Type torque wrench

    • N-Type uses 5/8-24 UNS thread — NOT compatible with SMA/3.5mm wrenches (1/4-36 UNS)

    • A SMA wrench will NOT fit the N-Type nut — forcing it damages both wrench and connector



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

SatCom Ground Station HPA

Full N-Type kit (9 pcs)

DC-18GHz, high power

100W+ amplifier test

Aerospace Flight-Line

CW-SOLT-N-LM

Fixed load, rugged

Field-deployable 18GHz test

Defense Radar Systems

CW-SOLT-N-TMM

M-M Thru, DC-18GHz

Radar system multiport cal

High-Power Amplifier ATE

CW-SOLT-N-TMF + Loads

M-F Thru, 500+ cycles

Production HPA test

7/16 DIN Base Stations

CW-SOLT-N-716

+7/16 DIN adapter, DC-7.5GHz

Cellular tower equipment

Legacy BNC Equipment

CW-SOLT-N-BNC

+BNC adapter, DC-4GHz

Legacy spectrum analyzer cal

National Metrology Lab

Full kit, metrology grade

±0.5% Z, 100% characterized

Primary 18GHz standard

Multiport VNA (4-port)

Full kit + 3 Thrus

M-M/F-F/M-F gender coverage

4-port full SOLT

University Teaching Lab

CW-SOLT-N-BNC

+BNC adapter, DC-4GHz

Educational lab, legacy gear

Production ATE

CW-SOLT-N-TMF + Loads

M-F Thru, 500+ cycles

High-volume RF device test


Standard Matrix & Extensions

  • Native Standards: N-Type Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) — 9 items

  • Adapter-Type Kits: +SMA, +3.5mm, +7/16 DIN, +BNC — 4 configurations

  • Full Kits: All 9 native standards + torque wrench + wooden case; or native + selected adapter

⚡ Electrical Performance Customization

  • Metrology-Grade Load: Return loss ≥ 25dB (DC-12GHz) for national labs

  • 7th-Order Polynomial Open: Extended polynomial for highest phase accuracy above 15GHz

  • Phase-Matched Standard Pairs: Two Shorts matched to ±0.5° for differential system test

Structural Customization

  • Panel-Mount Load: For semi-permanent calibration reference plane in ATE fixtures

  • Weatherproof Version: IP67-rated for outdoor flight-line use

  • Keyed Coupling Nut: Prevents mis-mating in confined test bays

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum computing RF test

  • Hermetically Sealed Load: For pressurized calibration environments

  • Extended Temperature Load: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every standard measured DC-18GHz

  • Independent Calibration Data Manual: Actual S-parameters, polynomial coefficients, DC resistance

  • SN Traceability: Laser-marked unique serial numbers on every standard

  • Torque Wrench Calibration: Included wrench pre-calibrated; recalibration service available

  • Rapid Prototyping: Standard kits 2-3 week shipment; custom 4-6 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • SOLT polynomial entry guidance for Keysight, R&S, Anritsu VNAs

    • N-Type handling and cleaning best practices

    • Cross-interface calibration plane management

    • Multiport SOLT sequencing for 4-port+ VNAs


Tip

"There is no perfect standard part, only the most suitable solution."

Standard SOLT Calibration (N-Type, DC-18GHz)

  • Full 2-Port SOLT on N-Type VNA:
    Use the complete native kit. Connect Short → Open → Load to each port, then Thru between ports. Enter Open 5th-order polynomial coefficients from the factory manual. The VNA computes all 12 error terms. Calibration uncertainty at 18GHz is limited only by the characterized data and connector repeatability.

  • Female-Thru for Reverse-Gender Cables:
    Use CW-SOLT-N-TFF when both VNA test cables terminate in male connectors. The F-F Thru provides the through-connection without extra gender-changer adapters.

Cross-Interface Calibration

  • N-Type VNA to 7/16 DIN DUT (DC-7.5GHz):
    Use CW-SOLT-N-716. Attach 7/16 DIN adapter to each N-Type standard. Calibrate at the 7/16 DIN plane. Frequency limited to DC-7.5GHz by 7/16 DIN. Essential for cellular base station HPA test where 7/16 DIN is the standard high-power interface.

  • N-Type VNA to SMA DUT (DC-18GHz):
    Use CW-SOLT-N-SMA. Same workflow, 18GHz upper limit. Ideal for transitioning between high-power N-Type test equipment and SMA DUTs.

Production ATE

  • High-Volume High-Power Device Test:
    Use CW-SOLT-N-TMF (M-F Thru) + Loads in automated calibration fixtures. 500+ mating cycles support high-throughput production. The M-F Thru eliminates gender-changer adapters in typical ATE cable configurations.

⚠️ Usage Red Lines

  • ⚠️ N-Type Torque: 1.1–1.3 N·m (10–12 in-lbs) — Use ONLY the Included Wrench:

    • The N-Type coupling thread is 5/8-24 UNS — NOT compatible with SMA/3.5mm wrenches (1/4-36 UNS)

    • A SMA wrench will NOT fit the N-Type nut — forcing it damages both wrench and connector

    • Under-tightening causes RF leakage; over-tightening cracks the PTFE dielectric → irreversible 18GHz performance loss


  • N-Type vs. TNC — Know the Difference:

    • TNC looks similar but uses a bayonet or threaded coupling (7/16-28 UNS) — it is NOT N-Type

    • Never attempt to mate N-Type with TNC — physical damage is guaranteed


  • ⚠️ Cross-Interface Frequency Boundaries Are Absolute:

    • SMA adapter: DC-18GHz (both sides rated ≥18GHz)

    • 3.5mm adapter: DC-18GHz (both sides rated ≥18GHz)

    • 7/16 DIN adapter: DC-7.5GHz max

    • BNC adapter: DC-4GHz max

    • For full 18GHz SOLT on a non-N-Type DUT, use the native cal kit for that interface


  • Clean the Open Aperture Gently:

    • The N-Type Open has an exposed precision gap — contamination changes fringing capacitance

    • Clean only with dry filtered air. No swabs, no solvents

    • Cap when not in use



Coaxwave N-Type SOLT Mechanical Calibration Kit · Delivery Commitment

  • Frequency: DC – 18 GHz (full N-Type precision band)

  • Impedance: 50Ω ±0.5%

  • Standards: Open (M/F), Short (M/F), Load (M/F), Thru (M-M/F-F/M-F) = 9 items

  • Adapter Kits: 4 cross-interface configurations (+SMA, +3.5mm, +7/16 DIN, +BNC)

  • Materials: Passivated stainless steel + BeCu gold-plated contacts + TaN thin-film load

  • 100% VNA Full-Band Characterization + Polynomial Extraction + DC Resistance Test + CMM Gauge + Independent Calibration Data Manual + Dedicated Torque Wrench + SN Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for N-Type SOLT Selection:

  1. N-Type Is the High-Power Choice: Unlike SMA or 3.5mm, N-Type handles 100W+ average power. For HPA test above 10W, N-Type is the only correct choice.

  2. The Included Torque Wrench Is Part of the Calibration Standard: An N-Type connector tightened to the wrong torque produces a different impedance than the characterized value. The included wrench is pre-calibrated to 1.1–1.3 N·m. If lost, contact Coaxwave for a replacement — do NOT use a SMA wrench.

  3. Always Enter the Polynomial Data: The 5th-order coefficients in your factory manual are YOUR unit's actual data. Using "ideal open" in your VNA discards this characterization and increases calibration residual error — especially above 12GHz where fringing becomes significant.


There is no perfect standard part, only the most suitable solution.

Coaxwave N-Type SOLT Mechanical Calibration Kits are not merely calibration accessories; they are the engineered foundation of accurate high-power RF measurement from DC to 18GHz. We machine every stainless-steel body and characterize every polynomial coefficient with "German precision" and "French engineering logic". With nine native standards, four cross-interface adapter kits, 100% VNA certification, and a dedicated torque wrench in every box, Coaxwave delivers the most suitable SOLT calibration benchmark for your exact aerospace, SatCom, defense, and high-power requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com