Coaxwave Non-Magnetic SMA Connectors are precision-engineered from the atomic level for environments where magnetic field purity is non-negotiable. Standard SMA connectors universally rely on nickel underplating, steel coupling nuts, or ferrous spring alloys — introducing residual magnetism that corrupts MRI B0 homogeneity, perturbs superconducting qubit states, and interferes with SQUID sensitivity. Coaxwave eliminates this at the material selection stage: iron, nickel, and cobalt are excluded entirely. The external conductor is beryllium copper, phosphor bronze, or titanium alloy. The center contact is non-magnetic beryllium copper, gold-plated without any nickel barrier layer. The dielectric is virgin PTFE or PEI. Every unit is validated from 10 mK to +165℃ and ships with an independent non-magnetic test report confirming magnetic susceptibility below 10⁻⁵ and field strength below 0.1 milligauss.
Architecture — Ferrous-Free by Design, Cryogenic to Industrial Temperature
Attribute | Non-Magnetic SMA Connector Specification |
|---|---|
Characteristic Impedance | 50Ω ±2Ω |
Frequency Range | DC–18GHz (standard); DC–26.5GHz (extended on select structures) |
Coupling Mechanism | Threaded 1/4-36 UNS, hand-tight (~0.9 N·m) |
VSWR (Factory) | ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz, extended) |
Insertion Loss | ≤ 0.05 × √f(GHz) dB (typical, per mated pair) |
Body Material (Option A) | Beryllium copper, gold-plated (no Ni underplate) |
Body Material (Option B) | Phosphor bronze, gold-plated (μr ≈ 1.0003) |
Body Material (Option C) | Titanium alloy Ti-6Al-4V, passivated (μr ≈ 1.0002) |
Center Contact | Beryllium copper (non-magnetic grade), direct gold-plated — zero Ni |
Dielectric | PTFE (Teflon®) or PEI (Polyetherimide) — both non-magnetic |
Magnetic Susceptibility | < 10⁻⁵ (verified per unit) |
Residual Field Strength | < 0.1 milligauss |
Operating Temperature | 10 mK – +165℃ (validated across full range) |
All Transfer Models (every combination across all gender sets and cross-series interfaces):
No. | Model Family | End A | End B | Max Freq | Notes |
|---|---|---|---|---|---|
1 | CW-NM-SMA-SMA-MM | SMA Male | SMA Male | DC–26.5GHz | In-line barrel |
2 | CW-NM-SMA-SMA-MF | SMA Male | SMA Female | DC–26.5GHz | Standard jumper |
3 | CW-NM-SMA-SMA-FF | SMA Female | SMA Female | DC–26.5GHz | Panel feedthrough |
4 | CW-NM-SMA-292-MM | SMA Male | 2.92mm (K) Male | DC–26.5GHz | 26.5GHz to 40GHz bridge |
5 | CW-NM-SMA-292-MF | SMA Male | 2.92mm (K) Female | DC–26.5GHz | K-port adaptation |
6 | CW-NM-SMA-292-FF | SMA Female | 2.92mm (K) Female | DC–26.5GHz | 2.92mm panel |
7 | CW-NM-SMA-35-MM | SMA Male | 3.5mm Male | DC–26.5GHz | Precision test bridge |
8 | CW-NM-SMA-35-MF | SMA Male | 3.5mm Female | DC–26.5GHz | 3.5mm test port |
9 | CW-NM-SMA-35-FF | SMA Female | 3.5mm Female | DC–26.5GHz | 3.5mm panel |
10 | CW-NM-SMA-N-MM | SMA Male | N-Type Male | DC–18GHz | 26.5GHz to 18GHz bridge |
11 | CW-NM-SMA-N-MF | SMA Male | N-Type Female | DC–18GHz | N-Type antenna feed |
12 | CW-NM-SMA-N-FF | SMA Female | N-Type Female | DC–18GHz | N-Type panel |
13 | CW-NM-SMA-BNC-MM | SMA Male | BNC Male | DC–4GHz | Quick-connect bridge |
14 | CW-NM-SMA-BNC-MF | SMA Male | BNC Female | DC–4GHz | BNC test port |
15 | CW-NM-SMA-BNC-FF | SMA Female | BNC Female | DC–4GHz | BNC panel |
16 | CW-NM-SMA-MCX-MM | SMA Male | MCX Male | DC–6GHz | Sub-miniature bridge |
17 | CW-NM-SMA-MCX-MF | SMA Male | MCX Female | DC–6GHz | MCX interface |
18 | CW-NM-SMA-MMCX-MM | SMA Male | MMCX Male | DC–6GHz | Ultra-compact bridge |
19 | CW-NM-SMA-MMCX-MF | SMA Male | MMCX Female | DC–6GHz | MMCX panel |
💡 Every A-to-B combination across SMA, 2.92mm (K), 3.5mm, N-Type, BNC, MCX, and MMCX is supported. All genders (M/M, M/F, F/F), straight, 90° right-angle, bulkhead, 4-hole flange, and PCB-mount configurations available. Every connector is 100% non-magnetic verified and RF-tested before shipment.
Key Performance (Coaxwave Non-Magnetic SMA specification):
Frequency Range: DC–18GHz (standard); DC–26.5GHz (extended select structures)
VSWR: ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz extended)
Coupling: 1/4-36 UNS threaded — ~0.9 N·m, non-magnetic torque wrench required
Magnetic Certification: Independent test report per unit — susceptibility < 10⁻⁵, field < 0.1 milligauss
In a 7T MRI scanner, a single nickel-plated SMA coupling nut generates a localized magnetic dipole that distorts the B0 field by parts per million — enough to ruin spectral resolution. In a dilution refrigerator at 10 mK, ferromagnetic impurities in standard connector springs cause flux trapping that collapses qubit coherence. Coaxwave Non-Magnetic SMA Connectors are the only SMA interconnects validated from 10 millikelvin to 165℃ — a 165,000:1 temperature ratio. Three body materials let engineers choose the optimal balance of magnetic purity, conductivity, and mechanical strength: beryllium copper for best RF performance, phosphor bronze for lowest magnetic susceptibility at moderate cost, and titanium alloy for the most demanding quantum environments.
Same-Series Gender Sets:
SMA Male to SMA Male (CW-NM-SMA-SMA-MM): In-line barrel for extending jumper runs inside MRI suites and cryogenic dewars.
SMA Male to SMA Female (CW-NM-SMA-SMA-MF): Standard cable-end connector for RF coil feeds and dilution refrigerator wall penetration.
SMA Female to SMA Female (CW-NM-SMA-SMA-FF): Panel-mount feedthrough for sealed enclosures and SQUID dewar flanges.
Cross-Series Adapters:
SMA ↔ 2.92mm (K): Bridge non-magnetic SMA infrastructure to 40GHz 2.92mm test ports. Most common for quantum control line characterization.
SMA ↔ 3.5mm: Interface to precision 26.5GHz metrology equipment. Preferred for national standards lab calibration.
SMA ↔ N-Type: Adapt to 18GHz N-Type antenna systems. N-Type side requires 1.1 N·m torque wrench (non-magnetic).
SMA ↔ BNC: Quick-connect interface for low-frequency monitoring (≤4GHz). BNC side bayonet, no torque required.
SMA ↔ MCX: Sub-miniature bridge for compact sensor modules inside MRI coils.
SMA ↔ MMCX: Ultra-compact interface for dense multi-channel SQUID readout boards.
Mounting Configurations:
Straight Cable: Standard crimp or solder termination for flexible and semi-rigid cables.
90° Right-Angle: For enclosures where cable exit direction must be controlled in dense cryogenic setups.
Bulkhead (Front/Rear): Weather-sealed or vacuum-flange entry for MRI scanner rooms and dilution refrigerator walls.
4-Hole Flange: Secure panel penetration for SQUID dewar lids and gradient coil housings.
PCB Edge-Mount / Through-Hole: Board-level integration in quantum control electronics.
Every Non-Magnetic SMA Connector undergoes four mandatory 100% controls:
Independent Non-Magnetic Test Report: Per-unit measurement of magnetic susceptibility (< 10⁻⁵) and residual field strength (< 0.1 milligauss) using a calibrated magnetometer/susceptometer. Certificate issued with each shipment.
10 mK – +165℃ Thermal Cycle Validation: Per-batch verification of dimensional stability and contact integrity across the full temperature range.
100% VNA RF Test: Swept from 10 MHz to 18GHz (or 26.5GHz for extended structures). S11, S21 recorded.
Material Verification: XRF analysis confirming zero iron, nickel, and cobalt in plating layers and body material.
Characteristic Impedance: 50Ω ±2Ω
Frequency Range: DC–18GHz (standard); DC–26.5GHz (extended select structures)
VSWR: ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz extended)
Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)
Dielectric Withstanding Voltage: ≥ 500V RMS (at sea level)
Insulation Resistance: ≥ 2000 MΩ
Contact Resistance: Center ≤ 3.0 mΩ; Outer ≤ 1.5 mΩ
Coupling Mechanism: Threaded 1/4-36 UNS, hand-tight
Recommended Torque: ~0.9 N·m (use non-magnetic torque wrench — mandatory)
Mating Cycles: ≥ 500 (clean environment, proper non-magnetic torque)
Retention Force: Axial pull-off ≥ 80 N (mated)
Mounting Options: Straight cable, 90° right-angle, front/rear bulkhead, 4-hole flange, PCB edge-mount, PCB through-hole
Body / Shell (Option A): Beryllium copper, direct gold-plated — no nickel underplate, no iron
Body / Shell (Option B): Phosphor bronze, gold-plated — μr ≈ 1.0003, lowest cost non-magnetic option
Body / Shell (Option C): Titanium alloy Ti-6Al-4V, passivated — μr ≈ 1.0002, highest strength-to-weight
Center Contact: Beryllium copper (non-magnetic grade), direct gold-plated — zero nickel barrier layer
Dielectric: PTFE (Teflon®) or PEI (Polyetherimide) — both non-magnetic, virgin grade
Coupling Nut: Matching body material — BeCu gold / phosphor bronze gold / titanium
Operating Temperature: 10 mK – +165℃ (validated per batch across full range)
Cryogenic Performance: Verified at 10 mK (dilution refrigerator base temperature)
Magnetic Susceptibility: < 10⁻⁵ (verified per unit)
Residual Field Strength: < 0.1 milligauss
Outgassing: TML ≤ 1.0%, CVCM ≤ 0.1% (per ASTM E595, optional data available)
RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))
Quality System: ISO 9001:2015 / AS9100D
1/4-36 UNS Thread — ~0.9 N·m, Non-Magnetic Wrench Mandatory: Standard steel torque wrenches are ferromagnetic and strictly prohibited. Use only Coaxwave-supplied non-magnetic torque wrench or equivalent.
No Nickel Barrier = Different Torque Feel: Direct gold plating on BeCu has different lubricity than nickel-underplated gold. The 0.9 N·m specification accounts for this — do not overtighten based on feel.
Cleanroom Handling: At 18GHz, λ/4 ≈ 4.2 mm. Particle contamination at the interface causes measurable VSWR. Clean all mating surfaces with IPA before connection.
Cryogenic Thermal Contraction: Titanium contracts ~0.15% from 300K to 10 mK; BeCu contracts ~0.2%. Account for this in cable assembly length calculations for dilution refrigerator installations.
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
MRI RF Coil (7T+) | CW-NM-SMA-SMA-MF (Ti) | <0.1mG, 10mK–165℃ | Transmit/receive coil feed |
Quantum Dilution Fridge | CW-NM-SMA-SMA-FF (BeCu) | 10mK verified, no Ni | Qubit control line wall feedthrough |
SQUID System | CW-NM-SMA-MMCX-MF (Ti) | Ultra-compact, <10⁻⁵ | Multi-channel SQUID readout |
Precision Metrology Lab | CW-NM-SMA-35-MF (BeCu) | 26.5GHz, certified | National standards VNA |
Gradient Coil Interface | CW-NM-SMA-SMA-FL (Ti, 4-hole) | Zero field distortion | 7T gradient coil RF |
Cryogenic Probe Station | CW-NM-SMA-SMA-MF (PCB) | Edge-mount, 10mK | On-wafer quantum measurement |
Medical Imaging R&D | CW-NM-SMA-BNC-MF (BeCu) | Quick-connect, non-mag | Prototype MRI coil test |
Aerospace Quantum | CW-NM-SMA-292-MF (Ti) | Lightweight, 26.5GHz | Space-borne quantum sensor |
Particle Physics | CW-NM-SMA-N-MF (Ti) | 18GHz to N-Type | Beamline RF monitor |
Academic Quantum Lab | CW-NM-SMA-SMA-MM (BeCu) | General-purpose, 26.5GHz | Superconducting circuit test |
Gender Sets: M-M, M-F, F-F in SMA (all non-magnetic)
Cross-Series Adapters: SMA ↔ 2.92mm / 3.5mm / N-Type / BNC / MCX / MMCX (all genders)
Body Material Options: Beryllium copper gold / Phosphor bronze gold / Titanium alloy
Mounting Styles: Straight, 90° right-angle, front/rear bulkhead, 4-hole flange, PCB edge-mount, through-hole
Full Kit: Connector + non-magnetic torque wrench + protective caps + serialized test report
Extended Frequency (DC–26.5GHz): Select structures validated to 26.5GHz for 5G mmWave and quantum control applications
Phase-Matched Sets: Multiple connectors matched for multi-channel SQUID or qubit readout arrays
Custom Return Loss Target: VSWR optimization for specific bands (e.g., 1–18GHz quantum control focus)
Custom Flange Patterns: Non-standard hole spacing for legacy dilution refrigerator or SQUID dewar flanges
Captive Center Contact: For field-replaceable applications in sealed cryogenic systems
Right-Angle Variants: 90° for constrained cryogenic routing (BeCu and Ti options)
Heavy Gold Plating: Thick gold for maximum wear resistance in high-mating-cycle MRI service environments
High-Purity Alumina Dielectric: For extreme cryogenic thermal conductivity at 10 mK (consult Coaxwave)
Custom Alloy Certification: Material composition certificates with full elemental analysis (Fe/Ni/Co all reported as < detection limit)
100% Independent Non-Magnetic Test Report: Every connector ships with susceptibility (< 10⁻⁵) and field strength (< 0.1 mG) data
Serialized Traceability: Laser-marked serial numbers on connector bodies
Rapid Prototyping: Standard 2–3 weeks; custom 4–6 weeks (material certification + 10mK cycle validation)
Application Engineering: Coaxwave RF engineers provide:
Body material selection guidance (BeCu vs. phosphor bronze vs. titanium) based on magnetic field strength, temperature, and RF loss budget
Cryogenic cable assembly length calculation accounting for thermal contraction from 300K to 10 mK
Cross-series interface selection for MRI, quantum, and SQUID applications
VNA calibration and de-embedding support for 18–26.5GHz measurements
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: 7T MRI system, 32-channel receive head coil. Gradient switching at 200 A/μs. Any ferromagnetic part heats and distorts B0. Use CW-NM-SMA-SMA-MF (titanium alloy, PTFE dielectric, straight).
Workflow: Connector mounted on coil housing. Internal semi-rigid cable soldered to coil element. External SMA plug hand-tight (0.9 N·m, non-magnetic torque wrench). Magnet room entry — zero image artifact from connector. Field mapping confirms < 0.1 mG residual.
Why This Connector: Titanium body (μr ≈ 1.0002) with zero Ni/Fe/Co. Direct gold plating on BeCu center — no nickel barrier layer. 10 mK to +165℃ validated. Non-magnetic test report confirms < 10⁻⁵ susceptibility per unit.
Setup: Superconducting qubit chip at 10 mK. 16 control lines require 18GHz bandwidth for fast flux pulsing. Use CW-NM-SMA-SMA-FF (BeCu gold, 4-hole flange, PTFE dielectric).
Workflow: Connector flange-mounted on refrigerator wall. SMA male on internal cable hand-tight (0.9 N·m, non-magnetic wrench) to flange female. System cooled to 10 mK. Qubit coherence T2 within specification.
Why This Connector: BeCu gold body has best RF conductivity among non-magnetic options. No nickel underplate — critical for zero magnetic dipole. 10 mK validation ensures dimensional stability at base temperature. Full S-parameter report confirms 18GHz performance before cool-down.
Setup: SQUID array for dark matter detection. 64 readout channels in a compact dewar. Need ultra-compact non-magnetic interface. Use CW-NM-SMA-MMCX-MF (titanium, straight).
Workflow: SMA male on cryogenic RF chain hand-tight (non-magnetic wrench). MMCX female blind-mates to SQUID readout board. 64 channels connected in one push.
Why This Connector: MMCX blind-mate enables high-density 64-channel array. Titanium body ensures < 10⁻⁵ susceptibility. No Ni/Fe/Co anywhere. 10 mK operation verified.
⚠️ ABSOLUTELY NO FERROMAGNETIC TOOLS:
Standard steel torque wrenches, screwdrivers, and tweezers are FERROMAGNETIC
Using a magnetic tool near an MRI scanner or dilution refrigerator can permanently damage the experiment
Only non-magnetic stainless steel, brass, bronze, or titanium tools allowed. Coaxwave supplies a non-magnetic torque wrench on request
⚠️ 1/4-36 UNS Torque — ~0.9 N·m, Non-Magnetic Wrench Required:
Direct gold on BeCu has different lubricity than nickel-underplated gold. Over-tightening deforms threads
0.9 N·m is the specification. Use ONLY a non-magnetic torque wrench
⚠️ Verify Plating Stack Before Installation:
Standard SMA connectors have nickel underplate beneath gold. This connector does NOT
If a third-party connector is mixed into the same system, verify its plating stack — one nickel-plated part compromises the entire magnetic purity claim
⚠️ 10 mK Thermal Contraction Is Real:
Titanium contracts ~0.15% from 300K to 10 mK. BeCu contracts ~0.2%. PTFE contracts ~1.5%
Cable assemblies must be length-compensated for cryogenic installations. Do not use room-temperature tension specifications
Impedance: 50Ω ±2Ω
Frequency Range: DC–18GHz (standard); DC–26.5GHz (extended select structures)
VSWR: ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz extended)
Coupling: 1/4-36 UNS threaded, ~0.9 N·m (non-magnetic wrench mandatory)
Body Options: Beryllium copper gold / Phosphor bronze gold / Titanium alloy
Magnetic Properties: Susceptibility < 10⁻⁵, field strength < 0.1 milligauss (per-unit certificate)
Temperature Range: 10 mK – +165℃ (validated per batch)
Adapter Matrix: SMA ↔ SMA / 2.92mm / 3.5mm / N-Type / BNC / MCX / MMCX — any A-to-B, all genders
100% Non-Magnetic Test Report + 10mK–165℃ Validation + VNA S-Parameters + Serialized Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for Non-Magnetic SMA Selection:
Three Body Materials — Choose by Priority: Titanium for lowest μr and weight. Phosphor bronze for lowest cost non-magnetic. Beryllium copper for best RF conductivity. All exclude Fe/Ni/Co.
No Nickel Barrier Layer Is a Feature, Not a Defect: Direct gold on BeCu eliminates the #1 hidden source of residual magnetism. Torque feel is different — trust the 0.9 N·m specification, not your hand.
10 mK Validation Is Unique: This is the only SMA connector series validated from 10 millikelvin to 165℃. If your application involves cryogenic quantum or superconducting systems, this matters.
There is no perfect standard part, only the most suitable solution.
Coaxwave Non-Magnetic SMA Connectors are engineered interconnects where ferrous-free material purity, 10 mK–165℃ thermal validation, and direct-gold signal integrity deliver the most trusted <10⁻⁵ susceptibility SMA interface for MRI, quantum computing, and SQUID systems. Every connector is non-magnetic certified, cryogenically validated, and RF-tested with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning 2.92mm, 3.5mm, N-Type, BNC, MCX, and MMCX, Coaxwave delivers the most suitable non-magnetic SMA solution for your exact magnetic sensitivity requirement.
Sales Email: sales@coaxial-rf.com