Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃
  • Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃
  • Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃
  • Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃
  • 1/3
  • Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃
  • Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃
  • Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃

Coaxwave Non-Magnetic SMA DC-26.5GHz | BeCu Bronze Ti | No Ni Fe Co <0.1mG | MRI Quantum 10mK-165℃

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave Non-Magnetic SMA RF Coaxial Connectors are the core product of the non-magnetic series, purpose-engineered for quantum computing and MRI magnetic-sensitive environments. 50Ω characteristic impedance, DC–18GHz (extended to DC–26.5GHz on select structures). Ferrous elements (Fe/Ni/Co) excluded at material selection. Body: beryllium copper, phosphor bronze, or titanium alloy. Center contact: beryllium copper gold-plated, no nickel barrier. Dielectric: PTFE or PEI. Magnetic susceptibility < 10⁻⁵, field strength < 0.1 milligauss. Validated from 10 mK to +165℃. 100% independent non-magnetic test report per unit. Ideal for MRI RF coils, dilution refrigerators, and SQUID systems.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave Non-Magnetic SMA Connectors are precision-engineered from the atomic level for environments where magnetic field purity is non-negotiable. Standard SMA connectors universally rely on nickel underplating, steel coupling nuts, or ferrous spring alloys — introducing residual magnetism that corrupts MRI B0 homogeneity, perturbs superconducting qubit states, and interferes with SQUID sensitivity. Coaxwave eliminates this at the material selection stage: iron, nickel, and cobalt are excluded entirely. The external conductor is beryllium copper, phosphor bronze, or titanium alloy. The center contact is non-magnetic beryllium copper, gold-plated without any nickel barrier layer. The dielectric is virgin PTFE or PEI. Every unit is validated from 10 mK to +165℃ and ships with an independent non-magnetic test report confirming magnetic susceptibility below 10⁻⁵ and field strength below 0.1 milligauss.

Architecture — Ferrous-Free by Design, Cryogenic to Industrial Temperature

Attribute

Non-Magnetic SMA Connector Specification

Characteristic Impedance

50Ω ±2Ω

Frequency Range

DC–18GHz (standard); DC–26.5GHz (extended on select structures)

Coupling Mechanism

Threaded 1/4-36 UNS, hand-tight (~0.9 N·m)

VSWR (Factory)

≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz, extended)

Insertion Loss

≤ 0.05 × √f(GHz) dB (typical, per mated pair)

Body Material (Option A)

Beryllium copper, gold-plated (no Ni underplate)

Body Material (Option B)

Phosphor bronze, gold-plated (μr ≈ 1.0003)

Body Material (Option C)

Titanium alloy Ti-6Al-4V, passivated (μr ≈ 1.0002)

Center Contact

Beryllium copper (non-magnetic grade), direct gold-plated — zero Ni

Dielectric

PTFE (Teflon®) or PEI (Polyetherimide) — both non-magnetic

Magnetic Susceptibility

< 10⁻⁵ (verified per unit)

Residual Field Strength

< 0.1 milligauss

Operating Temperature

10 mK – +165℃ (validated across full range)

All Transfer Models (every combination across all gender sets and cross-series interfaces):

No.

Model Family

End A

End B

Max Freq

Notes

1

CW-NM-SMA-SMA-MM

SMA Male

SMA Male

DC–26.5GHz

In-line barrel

2

CW-NM-SMA-SMA-MF

SMA Male

SMA Female

DC–26.5GHz

Standard jumper

3

CW-NM-SMA-SMA-FF

SMA Female

SMA Female

DC–26.5GHz

Panel feedthrough

4

CW-NM-SMA-292-MM

SMA Male

2.92mm (K) Male

DC–26.5GHz

26.5GHz to 40GHz bridge

5

CW-NM-SMA-292-MF

SMA Male

2.92mm (K) Female

DC–26.5GHz

K-port adaptation

6

CW-NM-SMA-292-FF

SMA Female

2.92mm (K) Female

DC–26.5GHz

2.92mm panel

7

CW-NM-SMA-35-MM

SMA Male

3.5mm Male

DC–26.5GHz

Precision test bridge

8

CW-NM-SMA-35-MF

SMA Male

3.5mm Female

DC–26.5GHz

3.5mm test port

9

CW-NM-SMA-35-FF

SMA Female

3.5mm Female

DC–26.5GHz

3.5mm panel

10

CW-NM-SMA-N-MM

SMA Male

N-Type Male

DC–18GHz

26.5GHz to 18GHz bridge

11

CW-NM-SMA-N-MF

SMA Male

N-Type Female

DC–18GHz

N-Type antenna feed

12

CW-NM-SMA-N-FF

SMA Female

N-Type Female

DC–18GHz

N-Type panel

13

CW-NM-SMA-BNC-MM

SMA Male

BNC Male

DC–4GHz

Quick-connect bridge

14

CW-NM-SMA-BNC-MF

SMA Male

BNC Female

DC–4GHz

BNC test port

15

CW-NM-SMA-BNC-FF

SMA Female

BNC Female

DC–4GHz

BNC panel

16

CW-NM-SMA-MCX-MM

SMA Male

MCX Male

DC–6GHz

Sub-miniature bridge

17

CW-NM-SMA-MCX-MF

SMA Male

MCX Female

DC–6GHz

MCX interface

18

CW-NM-SMA-MMCX-MM

SMA Male

MMCX Male

DC–6GHz

Ultra-compact bridge

19

CW-NM-SMA-MMCX-MF

SMA Male

MMCX Female

DC–6GHz

MMCX panel

💡 Every A-to-B combination across SMA, 2.92mm (K), 3.5mm, N-Type, BNC, MCX, and MMCX is supported. All genders (M/M, M/F, F/F), straight, 90° right-angle, bulkhead, 4-hole flange, and PCB-mount configurations available. Every connector is 100% non-magnetic verified and RF-tested before shipment.

Key Performance (Coaxwave Non-Magnetic SMA specification):

  • Frequency Range: DC–18GHz (standard); DC–26.5GHz (extended select structures)

  • VSWR: ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz extended)

  • Coupling: 1/4-36 UNS threaded — ~0.9 N·m, non-magnetic torque wrench required

  • Magnetic Certification: Independent test report per unit — susceptibility < 10⁻⁵, field < 0.1 milligauss

🎯 Core Positioning: Ferrous-Free at the Atomic Level — From 10 mK to +165℃

In a 7T MRI scanner, a single nickel-plated SMA coupling nut generates a localized magnetic dipole that distorts the B0 field by parts per million — enough to ruin spectral resolution. In a dilution refrigerator at 10 mK, ferromagnetic impurities in standard connector springs cause flux trapping that collapses qubit coherence. Coaxwave Non-Magnetic SMA Connectors are the only SMA interconnects validated from 10 millikelvin to 165℃ — a 165,000:1 temperature ratio. Three body materials let engineers choose the optimal balance of magnetic purity, conductivity, and mechanical strength: beryllium copper for best RF performance, phosphor bronze for lowest magnetic susceptibility at moderate cost, and titanium alloy for the most demanding quantum environments.

⚡ Complete Interface Matrix

Same-Series Gender Sets:

  • SMA Male to SMA Male (CW-NM-SMA-SMA-MM): In-line barrel for extending jumper runs inside MRI suites and cryogenic dewars.

  • SMA Male to SMA Female (CW-NM-SMA-SMA-MF): Standard cable-end connector for RF coil feeds and dilution refrigerator wall penetration.

  • SMA Female to SMA Female (CW-NM-SMA-SMA-FF): Panel-mount feedthrough for sealed enclosures and SQUID dewar flanges.

Cross-Series Adapters:

  • SMA ↔ 2.92mm (K): Bridge non-magnetic SMA infrastructure to 40GHz 2.92mm test ports. Most common for quantum control line characterization.

  • SMA ↔ 3.5mm: Interface to precision 26.5GHz metrology equipment. Preferred for national standards lab calibration.

  • SMA ↔ N-Type: Adapt to 18GHz N-Type antenna systems. N-Type side requires 1.1 N·m torque wrench (non-magnetic).

  • SMA ↔ BNC: Quick-connect interface for low-frequency monitoring (≤4GHz). BNC side bayonet, no torque required.

  • SMA ↔ MCX: Sub-miniature bridge for compact sensor modules inside MRI coils.

  • SMA ↔ MMCX: Ultra-compact interface for dense multi-channel SQUID readout boards.

Mounting Configurations:

  • Straight Cable: Standard crimp or solder termination for flexible and semi-rigid cables.

  • 90° Right-Angle: For enclosures where cable exit direction must be controlled in dense cryogenic setups.

  • Bulkhead (Front/Rear): Weather-sealed or vacuum-flange entry for MRI scanner rooms and dilution refrigerator walls.

  • 4-Hole Flange: Secure panel penetration for SQUID dewar lids and gradient coil housings.

  • PCB Edge-Mount / Through-Hole: Board-level integration in quantum control electronics.

🛡️ Coaxwave Quality Barrier

Every Non-Magnetic SMA Connector undergoes four mandatory 100% controls:

  1. Independent Non-Magnetic Test Report: Per-unit measurement of magnetic susceptibility (< 10⁻⁵) and residual field strength (< 0.1 milligauss) using a calibrated magnetometer/susceptometer. Certificate issued with each shipment.

  2. 10 mK – +165℃ Thermal Cycle Validation: Per-batch verification of dimensional stability and contact integrity across the full temperature range.

  3. 100% VNA RF Test: Swept from 10 MHz to 18GHz (or 26.5GHz for extended structures). S11, S21 recorded.

  4. Material Verification: XRF analysis confirming zero iron, nickel, and cobalt in plating layers and body material.


Electrical Performance

  • Characteristic Impedance: 50Ω ±2Ω

  • Frequency Range: DC–18GHz (standard); DC–26.5GHz (extended select structures)

  • VSWR: ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz extended)

  • Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)

  • Dielectric Withstanding Voltage: ≥ 500V RMS (at sea level)

  • Insulation Resistance: ≥ 2000 MΩ

  • Contact Resistance: Center ≤ 3.0 mΩ; Outer ≤ 1.5 mΩ

Mechanical Performance

  • Coupling Mechanism: Threaded 1/4-36 UNS, hand-tight

  • Recommended Torque: ~0.9 N·m (use non-magnetic torque wrench — mandatory)

  • Mating Cycles: ≥ 500 (clean environment, proper non-magnetic torque)

  • Retention Force: Axial pull-off ≥ 80 N (mated)

  • Mounting Options: Straight cable, 90° right-angle, front/rear bulkhead, 4-hole flange, PCB edge-mount, PCB through-hole

Materials & Structure

  • Body / Shell (Option A): Beryllium copper, direct gold-plated — no nickel underplate, no iron

  • Body / Shell (Option B): Phosphor bronze, gold-plated — μr ≈ 1.0003, lowest cost non-magnetic option

  • Body / Shell (Option C): Titanium alloy Ti-6Al-4V, passivated — μr ≈ 1.0002, highest strength-to-weight

  • Center Contact: Beryllium copper (non-magnetic grade), direct gold-plated — zero nickel barrier layer

  • Dielectric: PTFE (Teflon®) or PEI (Polyetherimide) — both non-magnetic, virgin grade

  • Coupling Nut: Matching body material — BeCu gold / phosphor bronze gold / titanium

Environment & Compliance

  • Operating Temperature: 10 mK – +165℃ (validated per batch across full range)

  • Cryogenic Performance: Verified at 10 mK (dilution refrigerator base temperature)

  • Magnetic Susceptibility: < 10⁻⁵ (verified per unit)

  • Residual Field Strength: < 0.1 milligauss

  • Outgassing: TML ≤ 1.0%, CVCM ≤ 0.1% (per ASTM E595, optional data available)

  • RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • 1/4-36 UNS Thread — ~0.9 N·m, Non-Magnetic Wrench Mandatory: Standard steel torque wrenches are ferromagnetic and strictly prohibited. Use only Coaxwave-supplied non-magnetic torque wrench or equivalent.

  • No Nickel Barrier = Different Torque Feel: Direct gold plating on BeCu has different lubricity than nickel-underplated gold. The 0.9 N·m specification accounts for this — do not overtighten based on feel.

  • Cleanroom Handling: At 18GHz, λ/4 ≈ 4.2 mm. Particle contamination at the interface causes measurable VSWR. Clean all mating surfaces with IPA before connection.

  • Cryogenic Thermal Contraction: Titanium contracts ~0.15% from 300K to 10 mK; BeCu contracts ~0.2%. Account for this in cable assembly length calculations for dilution refrigerator installations.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

MRI RF Coil (7T+)

CW-NM-SMA-SMA-MF (Ti)

<0.1mG, 10mK–165℃

Transmit/receive coil feed

Quantum Dilution Fridge

CW-NM-SMA-SMA-FF (BeCu)

10mK verified, no Ni

Qubit control line wall feedthrough

SQUID System

CW-NM-SMA-MMCX-MF (Ti)

Ultra-compact, <10⁻⁵

Multi-channel SQUID readout

Precision Metrology Lab

CW-NM-SMA-35-MF (BeCu)

26.5GHz, certified

National standards VNA

Gradient Coil Interface

CW-NM-SMA-SMA-FL (Ti, 4-hole)

Zero field distortion

7T gradient coil RF

Cryogenic Probe Station

CW-NM-SMA-SMA-MF (PCB)

Edge-mount, 10mK

On-wafer quantum measurement

Medical Imaging R&D

CW-NM-SMA-BNC-MF (BeCu)

Quick-connect, non-mag

Prototype MRI coil test

Aerospace Quantum

CW-NM-SMA-292-MF (Ti)

Lightweight, 26.5GHz

Space-borne quantum sensor

Particle Physics

CW-NM-SMA-N-MF (Ti)

18GHz to N-Type

Beamline RF monitor

Academic Quantum Lab

CW-NM-SMA-SMA-MM (BeCu)

General-purpose, 26.5GHz

Superconducting circuit test

Standard Matrix & Extensions

  • Gender Sets: M-M, M-F, F-F in SMA (all non-magnetic)

  • Cross-Series Adapters: SMA ↔ 2.92mm / 3.5mm / N-Type / BNC / MCX / MMCX (all genders)

  • Body Material Options: Beryllium copper gold / Phosphor bronze gold / Titanium alloy

  • Mounting Styles: Straight, 90° right-angle, front/rear bulkhead, 4-hole flange, PCB edge-mount, through-hole

  • Full Kit: Connector + non-magnetic torque wrench + protective caps + serialized test report

⚡ Electrical Performance Customization

  • Extended Frequency (DC–26.5GHz): Select structures validated to 26.5GHz for 5G mmWave and quantum control applications

  • Phase-Matched Sets: Multiple connectors matched for multi-channel SQUID or qubit readout arrays

  • Custom Return Loss Target: VSWR optimization for specific bands (e.g., 1–18GHz quantum control focus)

Structural Customization

  • Custom Flange Patterns: Non-standard hole spacing for legacy dilution refrigerator or SQUID dewar flanges

  • Captive Center Contact: For field-replaceable applications in sealed cryogenic systems

  • Right-Angle Variants: 90° for constrained cryogenic routing (BeCu and Ti options)

️ Material & Environmental Customization

  • Heavy Gold Plating: Thick gold for maximum wear resistance in high-mating-cycle MRI service environments

  • High-Purity Alumina Dielectric: For extreme cryogenic thermal conductivity at 10 mK (consult Coaxwave)

  • Custom Alloy Certification: Material composition certificates with full elemental analysis (Fe/Ni/Co all reported as < detection limit)

Service & Support

  • 100% Independent Non-Magnetic Test Report: Every connector ships with susceptibility (< 10⁻⁵) and field strength (< 0.1 mG) data

  • Serialized Traceability: Laser-marked serial numbers on connector bodies

  • Rapid Prototyping: Standard 2–3 weeks; custom 4–6 weeks (material certification + 10mK cycle validation)

  • Application Engineering: Coaxwave RF engineers provide:

    • Body material selection guidance (BeCu vs. phosphor bronze vs. titanium) based on magnetic field strength, temperature, and RF loss budget

    • Cryogenic cable assembly length calculation accounting for thermal contraction from 300K to 10 mK

    • Cross-series interface selection for MRI, quantum, and SQUID applications

    • VNA calibration and de-embedding support for 18–26.5GHz measurements


Tip

"There is no perfect standard part, only the most suitable solution."

MRI RF Coil — 7T Scanner, Titanium Body

  • Setup: 7T MRI system, 32-channel receive head coil. Gradient switching at 200 A/μs. Any ferromagnetic part heats and distorts B0. Use CW-NM-SMA-SMA-MF (titanium alloy, PTFE dielectric, straight).

  • Workflow: Connector mounted on coil housing. Internal semi-rigid cable soldered to coil element. External SMA plug hand-tight (0.9 N·m, non-magnetic torque wrench). Magnet room entry — zero image artifact from connector. Field mapping confirms < 0.1 mG residual.

  • Why This Connector: Titanium body (μr ≈ 1.0002) with zero Ni/Fe/Co. Direct gold plating on BeCu center — no nickel barrier layer. 10 mK to +165℃ validated. Non-magnetic test report confirms < 10⁻⁵ susceptibility per unit.

Quantum Dilution Refrigerator — 10 mK, BeCu Body

  • Setup: Superconducting qubit chip at 10 mK. 16 control lines require 18GHz bandwidth for fast flux pulsing. Use CW-NM-SMA-SMA-FF (BeCu gold, 4-hole flange, PTFE dielectric).

  • Workflow: Connector flange-mounted on refrigerator wall. SMA male on internal cable hand-tight (0.9 N·m, non-magnetic wrench) to flange female. System cooled to 10 mK. Qubit coherence T2 within specification.

  • Why This Connector: BeCu gold body has best RF conductivity among non-magnetic options. No nickel underplate — critical for zero magnetic dipole. 10 mK validation ensures dimensional stability at base temperature. Full S-parameter report confirms 18GHz performance before cool-down.

SQUID Readout — MMCX Cross-Series, Titanium

  • Setup: SQUID array for dark matter detection. 64 readout channels in a compact dewar. Need ultra-compact non-magnetic interface. Use CW-NM-SMA-MMCX-MF (titanium, straight).

  • Workflow: SMA male on cryogenic RF chain hand-tight (non-magnetic wrench). MMCX female blind-mates to SQUID readout board. 64 channels connected in one push.

  • Why This Connector: MMCX blind-mate enables high-density 64-channel array. Titanium body ensures < 10⁻⁵ susceptibility. No Ni/Fe/Co anywhere. 10 mK operation verified.

⚠️ Usage Red Lines

  • ⚠️ ABSOLUTELY NO FERROMAGNETIC TOOLS:

    • Standard steel torque wrenches, screwdrivers, and tweezers are FERROMAGNETIC

    • Using a magnetic tool near an MRI scanner or dilution refrigerator can permanently damage the experiment

    • Only non-magnetic stainless steel, brass, bronze, or titanium tools allowed. Coaxwave supplies a non-magnetic torque wrench on request


  • ⚠️ 1/4-36 UNS Torque — ~0.9 N·m, Non-Magnetic Wrench Required:

    • Direct gold on BeCu has different lubricity than nickel-underplated gold. Over-tightening deforms threads

    • 0.9 N·m is the specification. Use ONLY a non-magnetic torque wrench


  • ⚠️ Verify Plating Stack Before Installation:

    • Standard SMA connectors have nickel underplate beneath gold. This connector does NOT

    • If a third-party connector is mixed into the same system, verify its plating stack — one nickel-plated part compromises the entire magnetic purity claim


  • ⚠️ 10 mK Thermal Contraction Is Real:

    • Titanium contracts ~0.15% from 300K to 10 mK. BeCu contracts ~0.2%. PTFE contracts ~1.5%

    • Cable assemblies must be length-compensated for cryogenic installations. Do not use room-temperature tension specifications



Coaxwave Non-Magnetic SMA Connector · Delivery Commitment

  • Impedance: 50Ω ±2Ω

  • Frequency Range: DC–18GHz (standard); DC–26.5GHz (extended select structures)

  • VSWR: ≤ 1.25:1 (DC–18GHz); ≤ 1.35:1 (18–26.5GHz extended)

  • Coupling: 1/4-36 UNS threaded, ~0.9 N·m (non-magnetic wrench mandatory)

  • Body Options: Beryllium copper gold / Phosphor bronze gold / Titanium alloy

  • Magnetic Properties: Susceptibility < 10⁻⁵, field strength < 0.1 milligauss (per-unit certificate)

  • Temperature Range: 10 mK – +165℃ (validated per batch)

  • Adapter Matrix: SMA ↔ SMA / 2.92mm / 3.5mm / N-Type / BNC / MCX / MMCX — any A-to-B, all genders

  • 100% Non-Magnetic Test Report + 10mK–165℃ Validation + VNA S-Parameters + Serialized Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for Non-Magnetic SMA Selection:

  1. Three Body Materials — Choose by Priority: Titanium for lowest μr and weight. Phosphor bronze for lowest cost non-magnetic. Beryllium copper for best RF conductivity. All exclude Fe/Ni/Co.

  2. No Nickel Barrier Layer Is a Feature, Not a Defect: Direct gold on BeCu eliminates the #1 hidden source of residual magnetism. Torque feel is different — trust the 0.9 N·m specification, not your hand.

  3. 10 mK Validation Is Unique: This is the only SMA connector series validated from 10 millikelvin to 165℃. If your application involves cryogenic quantum or superconducting systems, this matters.


There is no perfect standard part, only the most suitable solution.

Coaxwave Non-Magnetic SMA Connectors are engineered interconnects where ferrous-free material purity, 10 mK–165℃ thermal validation, and direct-gold signal integrity deliver the most trusted <10⁻⁵ susceptibility SMA interface for MRI, quantum computing, and SQUID systems. Every connector is non-magnetic certified, cryogenically validated, and RF-tested with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning 2.92mm, 3.5mm, N-Type, BNC, MCX, and MMCX, Coaxwave delivers the most suitable non-magnetic SMA solution for your exact magnetic sensitivity requirement.

Sales Email: sales@coaxial-rf.com