Coaxwave Non-Magnetic 1.85mm (V-Type) Connectors are precision millimeter-wave interconnects designed from the material level for environments where magnetic field purity is critical. Standard 1.85mm connectors rely on spring steel or nickel-plated components that introduce ferromagnetic contamination — unacceptable in quantum computing dilution refrigerators, 7T+ MRI gradient systems, and superconducting quantum device test setups. Coaxwave eliminates this entirely: Non-Magnetic Stainless Steel 303 body (verified μr ≈ 1.001–1.01 per batch), non-magnetic beryllium copper center contact gold-plated, and PTFE or PEI dielectric — zero ferrous content. The M7×0.75 metric thread ensures consistent coupling force without magnetic compromise. Every unit ships with residual permeability test data and a DC–67GHz VNA full-band S-parameter report.
Architecture — SS303 Body, μr ≈ 1.001, 67GHz Bandwidth
Attribute | Non-Magnetic 1.85mm (V) Connector Specification |
|---|---|
Characteristic Impedance | 50Ω ±1Ω |
Frequency Range | DC–67GHz |
Coupling Mechanism | M7×0.75 metric thread, hand-tight (0.8 N·m max) |
VSWR (Factory) | ≤ 1.25:1 (DC–40GHz); ≤ 1.35:1 (40–67GHz) |
Insertion Loss | ≤ 0.04 × √f(GHz) dB (typical, per mated pair) |
Interface Standard | IEC 61169-33 derived, 1.85mm (V-Type) |
Body Material | Non-Magnetic Stainless Steel 303, passivated (μr ≈ 1.001–1.01) |
Center Contact | Beryllium copper (non-magnetic grade), gold-plated |
Dielectric Support | PTFE (Teflon®) or PEI (Polyetherimide), selectable |
Operating Temperature | -55℃ ~ +125℃ (4K cryogenic verified) |
Relative Permeability (μr) | 1.001–1.01 (verified per batch) |
All Transfer Models (every combination across all gender sets and cross-series interfaces):
No. | Model Family | End A | End B | Max Freq | Notes |
|---|---|---|---|---|---|
1 | CW-NM-185-185-MM | 1.85mm Male | 1.85mm Male | DC–67GHz | In-line barrel |
2 | CW-NM-185-185-MF | 1.85mm Male | 1.85mm Female | DC–67GHz | Standard jumper |
3 | CW-NM-185-185-FF | 1.85mm Female | 1.85mm Female | DC–67GHz | Panel feedthrough |
4 | CW-NM-185-24-MM | 1.85mm Male | 2.4mm Male | DC–50GHz | 67GHz to 50GHz bridge |
5 | CW-NM-185-24-MF | 1.85mm Male | 2.4mm Female | DC–50GHz | 2.4mm VNA port |
6 | CW-NM-185-24-FF | 1.85mm Female | 2.4mm Female | DC–50GHz | 2.4mm panel |
7 | CW-NM-185-292-MM | 1.85mm Male | 2.92mm (K) Male | DC–40GHz | 67GHz to 40GHz bridge |
8 | CW-NM-185-292-MF | 1.85mm Male | 2.92mm (K) Female | DC–40GHz | K-port adaptation |
9 | CW-NM-185-292-FF | 1.85mm Female | 2.92mm (K) Female | DC–40GHz | 2.92mm panel |
10 | CW-NM-185-35-MM | 1.85mm Male | 3.5mm Male | DC–34GHz | Precision to 34GHz |
11 | CW-NM-185-35-MF | 1.85mm Male | 3.5mm Female | DC–34GHz | 3.5mm test port |
12 | CW-NM-185-35-FF | 1.85mm Female | 3.5mm Female | DC–34GHz | 3.5mm panel |
13 | CW-NM-185-SMA-MM | 1.85mm Male | SMA Male | DC–26.5GHz | 67GHz to 26.5GHz |
14 | CW-NM-185-SMA-MF | 1.85mm Male | SMA Female | DC–26.5GHz | SMA test port |
15 | CW-NM-185-SMA-FF | 1.85mm Female | SMA Female | DC–26.5GHz | SMA panel |
16 | CW-NM-185-N-MM | 1.85mm Male | N-Type Male | DC–18GHz | High-power bridge |
17 | CW-NM-185-N-MF | 1.85mm Male | N-Type Female | DC–18GHz | N-Type antenna feed |
18 | CW-NM-185-N-FF | 1.85mm Female | N-Type Female | DC–18GHz | N-Type panel |
19 | CW-NM-185-SSMP-MM | 1.85mm Male | SSMP Male | DC–65GHz | Ultra-compact mmWave |
20 | CW-NM-185-SSMP-MF | 1.85mm Male | SSMP Female | DC–65GHz | SSMP blind-mate |
21 | CW-NM-185-SSMP-FF | 1.85mm Female | SSMP Female | DC–65GHz | SSMP panel |
💡 Every A-to-B combination across 1.85mm, 2.4mm, 2.92mm (K), 3.5mm, SMA, N-Type, and SSMP is supported. All genders (M/M, M/F, F/F), straight, 90° right-angle, bulkhead, and 4-hole square flange configurations available. Every connector is 100% residual permeability tested and DC–67GHz VNA S-parameter verified before shipment.
Key Performance (Coaxwave Non-Magnetic 1.85mm specification):
Frequency Range: DC–67GHz (1.85mm side); limited by lower-frequency interface on cross-series
VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.35:1 (40–67GHz)
Coupling: M7×0.75 metric thread — 0.8 N·m maximum, non-magnetic torque wrench required
Material Certification: Residual permeability test data per unit + batch composition analysis
In quantum computing and superconducting quantum devices, the margin for magnetic contamination is measured in nanoTeslas. A single standard stainless steel coupling nut (AISI 304 with cold-worked ferrite strings) can produce a stray field exceeding 10 µT at 5 mm distance — enough to decohere a transmon qubit. Coaxwave Non-Magnetic 1.85mm Connectors start with Non-Magnetic Stainless Steel 303, a grade specifically processed to eliminate martensitic phase transformation during machining. Combined with beryllium copper (C17510, non-magnetic certified) center contacts and gold plating, the entire assembly achieves μr ≈ 1.001–1.01 — effectively invisible to surrounding magnetic fields. This is not "low magnetic"; this is engineered non-magnetic from the raw material certificate to the finished part.
Same-Series Mounting Styles (all DC–67GHz, all non-magnetic):
Straight: Standard inline for flexible and semi-rigid millimeter-wave cables (0.047", 0.086").
90° Right-Angle: For cryogenic packaging where cable routing must turn within millimeters of a qubit chip.
Bulkhead: Rear-mount for sealed enclosures and dilution refrigerator flanges.
4-Hole Square Flange: Secure panel penetration for MRI gradient amplifier housings and quantum device packages.
Cross-Series Adapters:
1.85mm ↔ 2.4mm: Bridge 67GHz systems to 50GHz 2.4mm VNA ports. Most common for E-band (60–90GHz) test where the VNA has 2.4mm outputs.
1.85mm ↔ 2.92mm (K): Adapt 67GHz measurement chains to widely available 40GHz 2.92mm test equipment. Essential for 5G mmWave and 6G FR3 validation.
1.85mm ↔ 3.5mm: Interface to precision 34GHz test ports for metrology applications.
1.85mm ↔ SMA: Connect millimeter-wave quantum control lines to SMA-based room-temperature electronics (limited to 26.5GHz on SMA side).
1.85mm ↔ N-Type: High-power bridge for superconducting magnet power supply monitoring (limited to 18GHz).
1.85mm ↔ SSMP: Ultra-compact blind-mate for dense multi-channel quantum readout boards.
Every Non-Magnetic 1.85mm Connector undergoes four mandatory 100% controls:
100% Residual Permeability Test: Each unit measured with a calibrated permeameter. μr recorded and certified ≤ 1.01.
100% DC–67GHz VNA Full-Band S-Parameter Test: Swept from 10 MHz to 67 GHz. S11, S21, S12, S22 recorded. VSWR and insertion loss verified.
Dimensional Inspection: Critical interface dimensions per IEC 61169-33 checked with laser micrometers.
Visual Inspection: Per applicable RF connector visual standard — no debris, no plating defects, no thread damage.
Characteristic Impedance: 50Ω ±1Ω
Frequency Range: DC–67GHz (1.85mm side)
VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.35:1 (40–67GHz)
Insertion Loss: ≤ 0.04 × √f(GHz) dB (typical, per mated pair)
Dielectric Withstanding Voltage: ≥ 500V RMS (at sea level)
Insulation Resistance: ≥ 2000 MΩ
Contact Resistance: Center ≤ 3.0 mΩ; Outer ≤ 1.5 mΩ
Coupling Mechanism: M7×0.75 metric thread, hand-tight
Recommended Torque: 0.8 N·m maximum (use non-magnetic torque wrench)
Mating Cycles: ≥ 200 (clean environment, proper torque)
Retention Force: Axial pull-off ≥ 50 N (mated)
Mounting Options: Straight, 90° right-angle, bulkhead, 4-hole square flange
Body / Shell: Non-Magnetic Stainless Steel 303, passivated (μr ≈ 1.001–1.01)
Center Contact: Beryllium copper (C17510 non-magnetic grade), gold-plated
Dielectric Support: PTFE (Teflon®) or PEI (Polyetherimide) — selectable per application
Coupling Nut: Non-Magnetic Stainless Steel 303, M7×0.75 thread
Spring Contacts: Beryllium copper (non-magnetic grade), gold-plated
Operating Temperature: -55℃ ~ +125℃
Cryogenic Operation: Verified to 4K (dilution refrigerator compatible)
Magnetic Properties: μr ≈ 1.001–1.01 (verified per unit)
Outgassing: TML ≤ 1.0%, CVCM ≤ 0.1% (ASTM E595, optional data available)
RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))
Quality System: ISO 9001:2015 / AS9100D
M7×0.75 Thread — 0.8 N·m Maximum: Use a non-magnetic torque wrench. Standard steel wrenches are ferromagnetic and must NOT enter quantum or MRI environments.
Dielectric Selection — PTFE vs. PEI:
PTFE: Lower cost, excellent electrical properties, cryogenic stable
PEI: Higher dimensional rigidity at elevated temperatures, preferred for repeated mating cycles
Cryogenic Thermal Contraction: SS303 contracts ~0.25% from 300K to 4K. Cable assembly lengths must be compensated.
Cross-Series Torque: When adapting to SMA or N-Type, use non-magnetic torque wrenches at the specified torque for those interfaces.
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
Quantum Computing (Dilution Fridge) | CW-NM-185-185-MF (Flange) | μr≈1.001, 4K rated | Qubit control line feedthrough |
MRI Gradient Amplifier | CW-NM-185-185-FF (Square Flange) | Zero field perturbation | Gradient coil RF interface |
Superconducting Quantum Device | CW-NM-185-185-MF (RA) | 90° right-angle, non-magnetic | Cryogenic probe routing |
Precision Magnetic Field Measurement | CW-NM-185-292-MF | 67GHz to 2.92mm | SQUID readout interface |
6G FR3 Validation | CW-NM-185-292-MF | 67GHz to 40GHz | OTA test port adaptation |
VNA Calibration Lab | CW-NM-185-24-MM | 67GHz reference | Cal kit to DUT bridge |
Quantum Control Electronics | CW-NM-185-SSMP-MF | Blind-mate, ultra-compact | Multi-channel readout board |
Metrology / Standards Lab | CW-NM-185-35-MF | Precision 34GHz | National lab measurement |
Cryogenic Probe Station | CW-NM-185-185-MF (Bulkhead) | Rear-mount, sealed | On-wafer mmWave at 4K |
Superconducting Magnet Monitoring | CW-NM-185-N-MF | High-power, non-magnetic | Magnet current sensor RF |
Gender Sets: M-M, M-F, F-F in 1.85mm (all non-magnetic)
Mounting Styles: Straight, 90° right-angle, bulkhead, 4-hole flange
Cross-Series Adapters: 1.85mm ↔ 2.4mm / 2.92mm / 3.5mm / SMA / N-Type / SSMP (all genders)
Full Kit: Connector + non-magnetic torque wrench + protective caps + serialized S-parameter report + permeability certificate
Extended Frequency Validation: DC–67GHz S-parameters provided as standard; custom frequency grids or additional measurement points available on request
Phase-Matched Sets: Multiple connectors matched for MIMO quantum readout or phased-array calibration
Custom Return Loss Target: VSWR optimization for specific bands (e.g., 40–50GHz focus)
Custom Flange Patterns: Non-standard hole spacing for legacy dilution refrigerator or MRI probe flanges
Captive Center Contact: For field-replaceable applications in sealed cryogenic systems
Right-Angle Variants: 90° for dense cryogenic packaging
316L Stainless Steel Body: For even lower magnetic susceptibility (μr ≈ 1.003, special order)
High-Purity Alumina Dielectric: For extreme cryogenic thermal conductivity requirements (consult Coaxwave)
Gold-Plated Stainless Steel: For maximum corrosion resistance in humid laboratory environments
100% VNA Test + Permeability Certification: Every connector ships with DC–67GHz S-parameters and residual permeability test report
Serialized Traceability: Laser-marked serial numbers on connector bodies
Rapid Prototyping: Standard 2–3 weeks; custom 4–6 weeks (material certification cycle)
Application Engineering: Coaxwave RF engineers provide:
Material selection guidance (SS303 vs. 316L) based on magnetic field strength and temperature
Cryogenic cable assembly length calculation accounting for thermal contraction
Cross-series interface selection for quantum, MRI, and superconducting applications
VNA calibration and de-embedding support for 67GHz measurements
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: Superconducting qubit chip inside dilution refrigerator. Control lines require 67GHz bandwidth for fast flux pulsing. Use CW-NM-185-185-BH (bulkhead, SS303, PTFE dielectric).
Workflow: Connector bulkhead-mounted on refrigerator wall. 1.85mm male on internal semi-rigid cable hand-tight (0.9 N·m, non-magnetic torque wrench) to bulkhead female. External VNA connected via 1.85mm cable. All tools verified non-magnetic before entry into fridge volume.
Why This Connector: μr ≈ 1.001–1.01 ensures zero field perturbation near qubits. 4K operation verified. Full S-parameter report confirms 67GHz performance before cool-down.
Setup: 3T MRI system, gradient amplifier driving X/Y/Z coils. RF feedthrough requires absolute magnetic purity. Use CW-NM-185-185-FL (4-hole flange, SS303, PEI dielectric).
Workflow: Connector mounted on gradient amplifier housing. Internal 1.85mm cable soldered to coil. External 1.85mm plug hand-tight to flange. Magnetic field mapping confirms no perturbation from connector body.
Why This Connector: PEI dielectric has excellent dimensional stability at MRI operating temperatures. SS303 verified μr ≈ 1.001–1.01. Non-magnetic certification provided with every unit.
Setup: Superconducting quantum interference device (SQUID) array for dark matter detection. Readout requires 67GHz bandwidth with zero magnetic contamination. Use CW-NM-185-SSMP-MF (SSMP blind-mate).
Workflow: 1.85mm male hand-tight (0.9 N·m, non-magnetic wrench) on cryogenic RF chain. SSMP female blind-mates to SQUID readout board. No rotation required for SSMP side — ideal for dense multi-channel arrays.
Why This Connector: SSMP blind-mate enables tool-free connection of 16+ channels in a single push. Non-magnetic throughout the signal path. μr verified per unit.
⚠️ ABSOLUTELY NO MAGNETIC TOOLS:
Standard steel torque wrenches, screwdrivers, and tweezers are FERROMAGNETIC
Using a magnetic tool near a quantum system or MRI magnet can permanently damage the experiment
Only non-magnetic stainless steel or brass tools allowed. Coaxwave supplies a non-magnetic torque wrench on request
⚠️ 1/4-36 UNS Torque — 0.9 N·m MAXIMUM:
1.85mm interfaces are precision-machined to micron tolerances. Over-tightening deforms the air-dielectric gap and destroys VSWR
0.9 N·m is the absolute maximum. Hand-tight until snug is often sufficient
⚠️ Cleanroom Handling Mandatory:
At 67GHz, λ/4 ≈ 1.1 mm. A 20 μm particle at the interface causes a measurable impedance step
Clean all mating surfaces with IPA under microscope before EVERY connection
⚠️ Cryogenic Thermal Contraction:
Stainless steel contracts ~0.3% from room temperature to 4K. Cable assemblies must be length-compensated
Do not use room-temperature cable tension specifications for cryogenic installations
Impedance: 50Ω ±1Ω
Frequency Range: DC–67GHz
VSWR: ≤ 1.30:1 (DC–50GHz); ≤ 1.35:1 (50–67GHz)
Coupling: 1/4-36 UNS threaded, 0.9 N·m max
Magnetic Properties: μr = 1.001–1.01 (SS303, verified per unit)
Temperature Range: -55℃ ~ +125℃ (4K cryogenic verified)
Material System: SS303 body, BeCu gold center, PTFE/PEI dielectric
Adapter Matrix: 1.85mm ↔ 1.85mm / 2.4mm / 2.92mm / 3.5mm / SMA / N-Type / SSMP — any A-to-B, all genders
100% Residual Permeability Test + DC–67GHz VNA S-Parameter Test + Serialized Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for Non-Magnetic 1.85mm Selection:
Permeability Certification Is Not Optional: In quantum and MRI applications, you cannot assume a connector is non-magnetic. Coaxwave provides per-unit permeability test with every shipment — no exceptions.
Non-Magnetic Tools Are a System Requirement: The connector is only as non-magnetic as the tools used to install it. A single steel torque wrench negates the entire material investment.
67GHz Demands Cleanliness: At this frequency, the connector interface is optically small. Particle contamination is the #1 cause of elevated VSWR in field returns.
There is no perfect standard part, only the most suitable solution.
Coaxwave Non-Magnetic 1.85mm Connectors are engineered interconnects where atomic-level material purity, precision 1/4-36 UNS coupling, and air-dielectric millimeter-wave architecture deliver the only truly non-magnetic 67GHz interface for quantum computing, MRI gradient amplifiers, superconducting quantum devices, and precision magnetic field measurement. Every connector is DC–67GHz VNA-tested, permeability-certified, and cryogenically validated with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning 2.4mm, 2.92mm, 3.5mm, SMA, N-Type, and SSMP, Coaxwave delivers the most suitable non-magnetic 1.85mm solution for your exact quantum, medical imaging, and superconducting requirement.
Sales Email: sales@coaxial-rf.com
Company Website: