Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMPCoaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMPCoaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP
  • Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP
  • Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP
  • Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP
  • 1/3
  • Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP
  • Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP
  • Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP

Coaxwave Non-Magnetic 1.85mm (V) DC-67GHz | SS303 BeCu Gold μr≈1.001 | Quantum MRI Superconducting | 2.4/2.92/3.5/SMA/N/SSMP

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave Non-Magnetic 1.85mm (V-Type) RF Coaxial Connectors are the core millimeter-wave products of the non-magnetic series, engineered for magnetically sensitive environments. 50Ω characteristic impedance, DC–67GHz. Non-magnetic stainless steel 303 body, beryllium copper gold-plated center contact, PTFE or PEI dielectric — residual relative permeability μr ≈ 1.001–1.01. Covers straight / 90° right-angle / bulkhead / 4-hole square flange same-series and 1.85mm ↔ 2.4mm / 2.92mm / 3.5mm / SMA / N-Type / SSMP cross-series full gender matrix. 100% residual permeability tested and DC–67GHz VNA S-parameter verified. Ideal for quantum computing, MRI gradient amplifiers, superconducting quantum devices, and precision magnetic field measurement.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave Non-Magnetic 1.85mm (V-Type) Connectors are precision millimeter-wave interconnects designed from the material level for environments where magnetic field purity is critical. Standard 1.85mm connectors rely on spring steel or nickel-plated components that introduce ferromagnetic contamination — unacceptable in quantum computing dilution refrigerators, 7T+ MRI gradient systems, and superconducting quantum device test setups. Coaxwave eliminates this entirely: Non-Magnetic Stainless Steel 303 body (verified μr ≈ 1.001–1.01 per batch), non-magnetic beryllium copper center contact gold-plated, and PTFE or PEI dielectric — zero ferrous content. The M7×0.75 metric thread ensures consistent coupling force without magnetic compromise. Every unit ships with residual permeability test data and a DC–67GHz VNA full-band S-parameter report.

Architecture — SS303 Body, μr ≈ 1.001, 67GHz Bandwidth

Attribute

Non-Magnetic 1.85mm (V) Connector Specification

Characteristic Impedance

50Ω ±1Ω

Frequency Range

DC–67GHz

Coupling Mechanism

M7×0.75 metric thread, hand-tight (0.8 N·m max)

VSWR (Factory)

≤ 1.25:1 (DC–40GHz); ≤ 1.35:1 (40–67GHz)

Insertion Loss

≤ 0.04 × √f(GHz) dB (typical, per mated pair)

Interface Standard

IEC 61169-33 derived, 1.85mm (V-Type)

Body Material

Non-Magnetic Stainless Steel 303, passivated (μr ≈ 1.001–1.01)

Center Contact

Beryllium copper (non-magnetic grade), gold-plated

Dielectric Support

PTFE (Teflon®) or PEI (Polyetherimide), selectable

Operating Temperature

-55℃ ~ +125℃ (4K cryogenic verified)

Relative Permeability (μr)

1.001–1.01 (verified per batch)

All Transfer Models (every combination across all gender sets and cross-series interfaces):

No.

Model Family

End A

End B

Max Freq

Notes

1

CW-NM-185-185-MM

1.85mm Male

1.85mm Male

DC–67GHz

In-line barrel

2

CW-NM-185-185-MF

1.85mm Male

1.85mm Female

DC–67GHz

Standard jumper

3

CW-NM-185-185-FF

1.85mm Female

1.85mm Female

DC–67GHz

Panel feedthrough

4

CW-NM-185-24-MM

1.85mm Male

2.4mm Male

DC–50GHz

67GHz to 50GHz bridge

5

CW-NM-185-24-MF

1.85mm Male

2.4mm Female

DC–50GHz

2.4mm VNA port

6

CW-NM-185-24-FF

1.85mm Female

2.4mm Female

DC–50GHz

2.4mm panel

7

CW-NM-185-292-MM

1.85mm Male

2.92mm (K) Male

DC–40GHz

67GHz to 40GHz bridge

8

CW-NM-185-292-MF

1.85mm Male

2.92mm (K) Female

DC–40GHz

K-port adaptation

9

CW-NM-185-292-FF

1.85mm Female

2.92mm (K) Female

DC–40GHz

2.92mm panel

10

CW-NM-185-35-MM

1.85mm Male

3.5mm Male

DC–34GHz

Precision to 34GHz

11

CW-NM-185-35-MF

1.85mm Male

3.5mm Female

DC–34GHz

3.5mm test port

12

CW-NM-185-35-FF

1.85mm Female

3.5mm Female

DC–34GHz

3.5mm panel

13

CW-NM-185-SMA-MM

1.85mm Male

SMA Male

DC–26.5GHz

67GHz to 26.5GHz

14

CW-NM-185-SMA-MF

1.85mm Male

SMA Female

DC–26.5GHz

SMA test port

15

CW-NM-185-SMA-FF

1.85mm Female

SMA Female

DC–26.5GHz

SMA panel

16

CW-NM-185-N-MM

1.85mm Male

N-Type Male

DC–18GHz

High-power bridge

17

CW-NM-185-N-MF

1.85mm Male

N-Type Female

DC–18GHz

N-Type antenna feed

18

CW-NM-185-N-FF

1.85mm Female

N-Type Female

DC–18GHz

N-Type panel

19

CW-NM-185-SSMP-MM

1.85mm Male

SSMP Male

DC–65GHz

Ultra-compact mmWave

20

CW-NM-185-SSMP-MF

1.85mm Male

SSMP Female

DC–65GHz

SSMP blind-mate

21

CW-NM-185-SSMP-FF

1.85mm Female

SSMP Female

DC–65GHz

SSMP panel

💡 Every A-to-B combination across 1.85mm, 2.4mm, 2.92mm (K), 3.5mm, SMA, N-Type, and SSMP is supported. All genders (M/M, M/F, F/F), straight, 90° right-angle, bulkhead, and 4-hole square flange configurations available. Every connector is 100% residual permeability tested and DC–67GHz VNA S-parameter verified before shipment.

Key Performance (Coaxwave Non-Magnetic 1.85mm specification):

  • Frequency Range: DC–67GHz (1.85mm side); limited by lower-frequency interface on cross-series

  • VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.35:1 (40–67GHz)

  • Coupling: M7×0.75 metric thread — 0.8 N·m maximum, non-magnetic torque wrench required

  • Material Certification: Residual permeability test data per unit + batch composition analysis

🎯 Core Positioning: SS303 at the Molecular Level — μr ≈ 1.001

In quantum computing and superconducting quantum devices, the margin for magnetic contamination is measured in nanoTeslas. A single standard stainless steel coupling nut (AISI 304 with cold-worked ferrite strings) can produce a stray field exceeding 10 µT at 5 mm distance — enough to decohere a transmon qubit. Coaxwave Non-Magnetic 1.85mm Connectors start with Non-Magnetic Stainless Steel 303, a grade specifically processed to eliminate martensitic phase transformation during machining. Combined with beryllium copper (C17510, non-magnetic certified) center contacts and gold plating, the entire assembly achieves μr ≈ 1.001–1.01 — effectively invisible to surrounding magnetic fields. This is not "low magnetic"; this is engineered non-magnetic from the raw material certificate to the finished part.

⚡ Complete Interface Matrix

Same-Series Mounting Styles (all DC–67GHz, all non-magnetic):

  • Straight: Standard inline for flexible and semi-rigid millimeter-wave cables (0.047", 0.086").

  • 90° Right-Angle: For cryogenic packaging where cable routing must turn within millimeters of a qubit chip.

  • Bulkhead: Rear-mount for sealed enclosures and dilution refrigerator flanges.

  • 4-Hole Square Flange: Secure panel penetration for MRI gradient amplifier housings and quantum device packages.

Cross-Series Adapters:

  • 1.85mm ↔ 2.4mm: Bridge 67GHz systems to 50GHz 2.4mm VNA ports. Most common for E-band (60–90GHz) test where the VNA has 2.4mm outputs.

  • 1.85mm ↔ 2.92mm (K): Adapt 67GHz measurement chains to widely available 40GHz 2.92mm test equipment. Essential for 5G mmWave and 6G FR3 validation.

  • 1.85mm ↔ 3.5mm: Interface to precision 34GHz test ports for metrology applications.

  • 1.85mm ↔ SMA: Connect millimeter-wave quantum control lines to SMA-based room-temperature electronics (limited to 26.5GHz on SMA side).

  • 1.85mm ↔ N-Type: High-power bridge for superconducting magnet power supply monitoring (limited to 18GHz).

  • 1.85mm ↔ SSMP: Ultra-compact blind-mate for dense multi-channel quantum readout boards.

🛡️ Coaxwave Quality Barrier

Every Non-Magnetic 1.85mm Connector undergoes four mandatory 100% controls:

  1. 100% Residual Permeability Test: Each unit measured with a calibrated permeameter. μr recorded and certified ≤ 1.01.

  2. 100% DC–67GHz VNA Full-Band S-Parameter Test: Swept from 10 MHz to 67 GHz. S11, S21, S12, S22 recorded. VSWR and insertion loss verified.

  3. Dimensional Inspection: Critical interface dimensions per IEC 61169-33 checked with laser micrometers.

  4. Visual Inspection: Per applicable RF connector visual standard — no debris, no plating defects, no thread damage.


Electrical Performance

  • Characteristic Impedance: 50Ω ±1Ω

  • Frequency Range: DC–67GHz (1.85mm side)

  • VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.35:1 (40–67GHz)

  • Insertion Loss: ≤ 0.04 × √f(GHz) dB (typical, per mated pair)

  • Dielectric Withstanding Voltage: ≥ 500V RMS (at sea level)

  • Insulation Resistance: ≥ 2000 MΩ

  • Contact Resistance: Center ≤ 3.0 mΩ; Outer ≤ 1.5 mΩ

Mechanical Performance

  • Coupling Mechanism: M7×0.75 metric thread, hand-tight

  • Recommended Torque: 0.8 N·m maximum (use non-magnetic torque wrench)

  • Mating Cycles: ≥ 200 (clean environment, proper torque)

  • Retention Force: Axial pull-off ≥ 50 N (mated)

  • Mounting Options: Straight, 90° right-angle, bulkhead, 4-hole square flange

Materials & Structure

  • Body / Shell: Non-Magnetic Stainless Steel 303, passivated (μr ≈ 1.001–1.01)

  • Center Contact: Beryllium copper (C17510 non-magnetic grade), gold-plated

  • Dielectric Support: PTFE (Teflon®) or PEI (Polyetherimide) — selectable per application

  • Coupling Nut: Non-Magnetic Stainless Steel 303, M7×0.75 thread

  • Spring Contacts: Beryllium copper (non-magnetic grade), gold-plated

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Cryogenic Operation: Verified to 4K (dilution refrigerator compatible)

  • Magnetic Properties: μr ≈ 1.001–1.01 (verified per unit)

  • Outgassing: TML ≤ 1.0%, CVCM ≤ 0.1% (ASTM E595, optional data available)

  • RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • M7×0.75 Thread — 0.8 N·m Maximum: Use a non-magnetic torque wrench. Standard steel wrenches are ferromagnetic and must NOT enter quantum or MRI environments.

  • Dielectric Selection — PTFE vs. PEI:

    • PTFE: Lower cost, excellent electrical properties, cryogenic stable

    • PEI: Higher dimensional rigidity at elevated temperatures, preferred for repeated mating cycles


  • Cryogenic Thermal Contraction: SS303 contracts ~0.25% from 300K to 4K. Cable assembly lengths must be compensated.

  • Cross-Series Torque: When adapting to SMA or N-Type, use non-magnetic torque wrenches at the specified torque for those interfaces.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

Quantum Computing (Dilution Fridge)

CW-NM-185-185-MF (Flange)

μr≈1.001, 4K rated

Qubit control line feedthrough

MRI Gradient Amplifier

CW-NM-185-185-FF (Square Flange)

Zero field perturbation

Gradient coil RF interface

Superconducting Quantum Device

CW-NM-185-185-MF (RA)

90° right-angle, non-magnetic

Cryogenic probe routing

Precision Magnetic Field Measurement

CW-NM-185-292-MF

67GHz to 2.92mm

SQUID readout interface

6G FR3 Validation

CW-NM-185-292-MF

67GHz to 40GHz

OTA test port adaptation

VNA Calibration Lab

CW-NM-185-24-MM

67GHz reference

Cal kit to DUT bridge

Quantum Control Electronics

CW-NM-185-SSMP-MF

Blind-mate, ultra-compact

Multi-channel readout board

Metrology / Standards Lab

CW-NM-185-35-MF

Precision 34GHz

National lab measurement

Cryogenic Probe Station

CW-NM-185-185-MF (Bulkhead)

Rear-mount, sealed

On-wafer mmWave at 4K

Superconducting Magnet Monitoring

CW-NM-185-N-MF

High-power, non-magnetic

Magnet current sensor RF

Standard Matrix & Extensions

  • Gender Sets: M-M, M-F, F-F in 1.85mm (all non-magnetic)

  • Mounting Styles: Straight, 90° right-angle, bulkhead, 4-hole flange

  • Cross-Series Adapters: 1.85mm ↔ 2.4mm / 2.92mm / 3.5mm / SMA / N-Type / SSMP (all genders)

  • Full Kit: Connector + non-magnetic torque wrench + protective caps + serialized S-parameter report + permeability certificate

⚡ Electrical Performance Customization

  • Extended Frequency Validation: DC–67GHz S-parameters provided as standard; custom frequency grids or additional measurement points available on request

  • Phase-Matched Sets: Multiple connectors matched for MIMO quantum readout or phased-array calibration

  • Custom Return Loss Target: VSWR optimization for specific bands (e.g., 40–50GHz focus)

Structural Customization

  • Custom Flange Patterns: Non-standard hole spacing for legacy dilution refrigerator or MRI probe flanges

  • Captive Center Contact: For field-replaceable applications in sealed cryogenic systems

  • Right-Angle Variants: 90° for dense cryogenic packaging

️ Material & Environmental Customization

  • 316L Stainless Steel Body: For even lower magnetic susceptibility (μr ≈ 1.003, special order)

  • High-Purity Alumina Dielectric: For extreme cryogenic thermal conductivity requirements (consult Coaxwave)

  • Gold-Plated Stainless Steel: For maximum corrosion resistance in humid laboratory environments

Service & Support

  • 100% VNA Test + Permeability Certification: Every connector ships with DC–67GHz S-parameters and residual permeability test report

  • Serialized Traceability: Laser-marked serial numbers on connector bodies

  • Rapid Prototyping: Standard 2–3 weeks; custom 4–6 weeks (material certification cycle)

  • Application Engineering: Coaxwave RF engineers provide:

    • Material selection guidance (SS303 vs. 316L) based on magnetic field strength and temperature

    • Cryogenic cable assembly length calculation accounting for thermal contraction

    • Cross-series interface selection for quantum, MRI, and superconducting applications

    • VNA calibration and de-embedding support for 67GHz measurements


Tip

"There is no perfect standard part, only the most suitable solution."

Quantum Computing — Dilution Refrigerator, 4K Operation

  • Setup: Superconducting qubit chip inside dilution refrigerator. Control lines require 67GHz bandwidth for fast flux pulsing. Use CW-NM-185-185-BH (bulkhead, SS303, PTFE dielectric).

  • Workflow: Connector bulkhead-mounted on refrigerator wall. 1.85mm male on internal semi-rigid cable hand-tight (0.9 N·m, non-magnetic torque wrench) to bulkhead female. External VNA connected via 1.85mm cable. All tools verified non-magnetic before entry into fridge volume.

  • Why This Connector: μr ≈ 1.001–1.01 ensures zero field perturbation near qubits. 4K operation verified. Full S-parameter report confirms 67GHz performance before cool-down.

MRI Gradient Amplifier — 3T System, Gradient Coil Interface

  • Setup: 3T MRI system, gradient amplifier driving X/Y/Z coils. RF feedthrough requires absolute magnetic purity. Use CW-NM-185-185-FL (4-hole flange, SS303, PEI dielectric).

  • Workflow: Connector mounted on gradient amplifier housing. Internal 1.85mm cable soldered to coil. External 1.85mm plug hand-tight to flange. Magnetic field mapping confirms no perturbation from connector body.

  • Why This Connector: PEI dielectric has excellent dimensional stability at MRI operating temperatures. SS303 verified μr ≈ 1.001–1.01. Non-magnetic certification provided with every unit.

⚡ Superconducting Quantum Device — SQUID Readout

  • Setup: Superconducting quantum interference device (SQUID) array for dark matter detection. Readout requires 67GHz bandwidth with zero magnetic contamination. Use CW-NM-185-SSMP-MF (SSMP blind-mate).

  • Workflow: 1.85mm male hand-tight (0.9 N·m, non-magnetic wrench) on cryogenic RF chain. SSMP female blind-mates to SQUID readout board. No rotation required for SSMP side — ideal for dense multi-channel arrays.

  • Why This Connector: SSMP blind-mate enables tool-free connection of 16+ channels in a single push. Non-magnetic throughout the signal path. μr verified per unit.

⚠️ Usage Red Lines

  • ⚠️ ABSOLUTELY NO MAGNETIC TOOLS:

    • Standard steel torque wrenches, screwdrivers, and tweezers are FERROMAGNETIC

    • Using a magnetic tool near a quantum system or MRI magnet can permanently damage the experiment

    • Only non-magnetic stainless steel or brass tools allowed. Coaxwave supplies a non-magnetic torque wrench on request


  • ⚠️ 1/4-36 UNS Torque — 0.9 N·m MAXIMUM:

    • 1.85mm interfaces are precision-machined to micron tolerances. Over-tightening deforms the air-dielectric gap and destroys VSWR

    • 0.9 N·m is the absolute maximum. Hand-tight until snug is often sufficient


  • ⚠️ Cleanroom Handling Mandatory:

    • At 67GHz, λ/4 ≈ 1.1 mm. A 20 μm particle at the interface causes a measurable impedance step

    • Clean all mating surfaces with IPA under microscope before EVERY connection


  • ⚠️ Cryogenic Thermal Contraction:

    • Stainless steel contracts ~0.3% from room temperature to 4K. Cable assemblies must be length-compensated

    • Do not use room-temperature cable tension specifications for cryogenic installations



Coaxwave Non-Magnetic 1.85mm Connector · Delivery Commitment

  • Impedance: 50Ω ±1Ω

  • Frequency Range: DC–67GHz

  • VSWR: ≤ 1.30:1 (DC–50GHz); ≤ 1.35:1 (50–67GHz)

  • Coupling: 1/4-36 UNS threaded, 0.9 N·m max

  • Magnetic Properties: μr = 1.001–1.01 (SS303, verified per unit)

  • Temperature Range: -55℃ ~ +125℃ (4K cryogenic verified)

  • Material System: SS303 body, BeCu gold center, PTFE/PEI dielectric

  • Adapter Matrix: 1.85mm ↔ 1.85mm / 2.4mm / 2.92mm / 3.5mm / SMA / N-Type / SSMP — any A-to-B, all genders

  • 100% Residual Permeability Test + DC–67GHz VNA S-Parameter Test + Serialized Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for Non-Magnetic 1.85mm Selection:

  1. Permeability Certification Is Not Optional: In quantum and MRI applications, you cannot assume a connector is non-magnetic. Coaxwave provides per-unit permeability test with every shipment — no exceptions.

  2. Non-Magnetic Tools Are a System Requirement: The connector is only as non-magnetic as the tools used to install it. A single steel torque wrench negates the entire material investment.

  3. 67GHz Demands Cleanliness: At this frequency, the connector interface is optically small. Particle contamination is the #1 cause of elevated VSWR in field returns.


There is no perfect standard part, only the most suitable solution.

Coaxwave Non-Magnetic 1.85mm Connectors are engineered interconnects where atomic-level material purity, precision 1/4-36 UNS coupling, and air-dielectric millimeter-wave architecture deliver the only truly non-magnetic 67GHz interface for quantum computing, MRI gradient amplifiers, superconducting quantum devices, and precision magnetic field measurement. Every connector is DC–67GHz VNA-tested, permeability-certified, and cryogenically validated with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning 2.4mm, 2.92mm, 3.5mm, SMA, N-Type, and SSMP, Coaxwave delivers the most suitable non-magnetic 1.85mm solution for your exact quantum, medical imaging, and superconducting requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com