Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMPCoaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMPCoaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP
  • Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP
  • Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP
  • Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP
  • 1/3
  • Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP
  • Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP
  • Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP

Coaxwave Non-Magnetic 2.4mm DC-50GHz | Brass Au / NM SS | No Ni Fe | MRI Quantum Metrology | 2.92/3.5/SMA/N/1.85/SMP

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave Non-Magnetic 2.4mm RF Coaxial Connectors are the core millimeter-wave products of the non-magnetic series, 50Ω characteristic impedance, DC–50GHz. Externally: brass gold-plated or non-magnetic stainless steel passivated — nickel and iron strictly excluded. Beryllium copper gold-plated center contact, PTFE dielectric. Residual magnetism quantified per customer magnetic sensitivity. Covers 2.4mm same-series and 2.4mm ↔ 2.92mm / 3.5mm / SMA / N-Type / 1.85mm / SMP cross-series full matrix. Each ships with independent non-magnetic test report (residual magnetism + DC–50GHz VNA S-parameters). Ideal for MRI RF coils, quantum cryogenic systems, particle accelerators, and precision metrology.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave Non-Magnetic 2.4mm Connectors are precision millimeter-wave interconnects engineered from the material level for environments where magnetic field purity is non-negotiable. The external conductor is available in brass gold-plated or non-magnetic stainless steel passivated — both options strictly exclude nickel and iron, the primary ferromagnetic contaminants in standard RF connectors. The center contact uses non-magnetic beryllium copper gold-plated. The dielectric is PTFE. Residual magnetism is not a generic claim; it is quantified per customer magnetic sensitivity threshold, measured and certified for each shipment. Every unit ships with an independent non-magnetic test report covering residual magnetism quantification and DC–50GHz VNA full-band S-parameter curves.

Architecture — Material-Pure, Magnetically Quantified

Attribute

Non-Magnetic 2.4mm Connector Specification

Characteristic Impedance

50Ω ±1Ω

Frequency Range

DC–50GHz

Coupling Mechanism

1/4-36 UNS threaded, hand-tight (0.7–0.9 N·m)

VSWR (Factory)

≤ 1.25:1 (DC–40GHz); ≤ 1.30:1 (40–50GHz)

Insertion Loss

≤ 0.05 × √f(GHz) dB (typical, per mated pair)

Interface

Air-dielectric, IEC 61169-32 derived

Body Material (Option A)

Brass, gold-plated (non-magnetic grade, no Ni underplate)

Body Material (Option B)

Non-magnetic stainless steel, passivated (μr ≈ 1.01, no Fe/Ni)

Center Contact

Beryllium copper (non-magnetic grade), gold-plated

Dielectric

PTFE (Teflon®) — no filler, no ferromagnetic additive

Operating Temperature

-55℃ ~ +125℃

Residual Magnetism

Quantified per unit, threshold customized to application

All Transfer Models (every combination across all gender sets and cross-series interfaces):

No.

Model Family

End A

End B

Max Freq

Notes

1

CW-NM-24-24-MM

2.4mm Male

2.4mm Male

DC–50GHz

In-line barrel

2

CW-NM-24-24-MF

2.4mm Male

2.4mm Female

DC–50GHz

Standard jumper

3

CW-NM-24-24-FF

2.4mm Female

2.4mm Female

DC–50GHz

Panel feedthrough

4

CW-NM-24-292-MM

2.4mm Male

2.92mm (K) Male

DC–40GHz

50GHz to 40GHz bridge

5

CW-NM-24-292-MF

2.4mm Male

2.92mm (K) Female

DC–40GHz

K-port adaptation

6

CW-NM-24-292-FF

2.4mm Female

2.92mm (K) Female

DC–40GHz

2.92mm panel

7

CW-NM-24-35-MM

2.4mm Male

3.5mm Male

DC–34GHz

50GHz to 34GHz bridge

8

CW-NM-24-35-MF

2.4mm Male

3.5mm Female

DC–34GHz

3.5mm test port

9

CW-NM-24-35-FF

2.4mm Female

3.5mm Female

DC–34GHz

3.5mm panel

10

CW-NM-24-SMA-MM

2.4mm Male

SMA Male

DC–26.5GHz

50GHz to 26.5GHz bridge

11

CW-NM-24-SMA-MF

2.4mm Male

SMA Female

DC–26.5GHz

SMA test port

12

CW-NM-24-SMA-FF

2.4mm Female

SMA Female

DC–26.5GHz

SMA panel

13

CW-NM-24-N-MM

2.4mm Male

N-Type Male

DC–18GHz

50GHz to 18GHz bridge

14

CW-NM-24-N-MF

2.4mm Male

N-Type Female

DC–18GHz

N-Type antenna feed

15

CW-NM-24-N-FF

2.4mm Female

N-Type Female

DC–18GHz

N-Type panel

16

CW-NM-24-185-MM

2.4mm Male

1.85mm Male

DC–50GHz

50GHz to 67GHz bridge

17

CW-NM-24-185-MF

2.4mm Male

1.85mm Female

DC–50GHz

1.85mm test port

18

CW-NM-24-185-FF

2.4mm Female

1.85mm Female

DC–50GHz

1.85mm panel

19

CW-NM-24-SMP-MM

2.4mm Male

SMP Male

DC–40GHz

Board-to-board mmWave

20

CW-NM-24-SMP-MF

2.4mm Male

SMP Female

DC–40GHz

SMP blind-mate

21

CW-NM-24-SMP-FF

2.4mm Female

SMP Female

DC–40GHz

SMP panel

💡 Every A-to-B combination across 2.4mm, 2.92mm (K), 3.5mm, SMA, N-Type, 1.85mm, and SMP is supported. All genders (M/M, M/F, F/F), straight, and panel-mount configurations available. Every connector is 100% residual magnetism quantified and DC–50GHz VNA verified before shipment.

Key Performance (Coaxwave Non-Magnetic 2.4mm specification):

  • Frequency Range: DC–50GHz (2.4mm side); limited by lower-frequency interface on cross-series

  • VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.30:1 (40–50GHz)

  • Coupling: 1/4-36 UNS threaded — 0.7–0.9 N·m, non-magnetic torque wrench recommended

  • Material Certification: Independent non-magnetic test report per unit — residual magnetism quantified + S-parameter curves

🎯 Core Positioning: Material-Pure by Design — No Nickel, No Iron, Period

Standard 2.4mm connectors often use nickel underplating on brass bodies or ferrous spring alloys — both introduce residual magnetism that corrupts sensitive magnetic field measurements. Coaxwave Non-Magnetic 2.4mm Connectors eliminate this at the source: Option A uses brass with direct gold plating (no nickel barrier layer). Option B uses non-magnetic stainless steel, passivated, with no iron content above trace impurity limits. The center contact is beryllium copper — inherently non-magnetic — gold-plated. The dielectric is virgin PTFE with no ferromagnetic filler. The result is a connector whose residual magnetism is not assumed but measured, quantified, and certified per unit against the customer's specified threshold.

⚡ Complete Interface Matrix

Same-Series Gender Sets:

  • 2.4mm Male to 2.4mm Male (CW-NM-24-24-MM): In-line barrel for extending millimeter-wave jumper runs in MRI suites and quantum labs.

  • 2.4mm Male to 2.4mm Female (CW-NM-24-24-MF): Standard cable-end connector for VNA test ports and RF coil feeds.

  • 2.4mm Female to 2.4mm Female (CW-NM-24-24-FF): Panel-mount feedthrough for cryogenic flanges and shielded enclosures.

Cross-Series Adapters:

  • 2.4mm ↔ 2.92mm (K): Most common bridge — 50GHz systems to 40GHz test ports. Essential for 5G mmWave and automotive radar validation.

  • 2.4mm ↔ 3.5mm: Interface to 34GHz precision metrology equipment. Preferred for aerospace calibration labs.

  • 2.4mm ↔ SMA: Connect 50GHz measurement chains to 26.5GHz SMA infrastructure. SMA side requires 0.9 N·m torque wrench.

  • 2.4mm ↔ N-Type: Adapt to 18GHz N-Type antenna systems. N-Type side requires 1.1 N·m torque wrench.

  • 2.4mm ↔ 1.85mm: Bridge to 67GHz 1.85mm systems. Enables 50GHz↔67GHz cross-reference in quantum and 6G research.

  • 2.4mm ↔ SMP: Blind-mate interface for dense multi-channel boards in superconducting quantum control systems.

🛡️ Coaxwave Quality Barrier

Every Non-Magnetic 2.4mm Connector undergoes three mandatory 100% controls:

  1. Residual Magnetism Quantification: Per-unit measurement using a calibrated magnetometer. Threshold set per customer specification. Certificate issued with each shipment.

  2. 100% DC–50GHz VNA Full-Band S-Parameter Test: Swept from 10 MHz to 50GHz. S11, S21, S12, S22 recorded. VSWR and insertion loss verified at every 100 MHz step.

  3. Material Verification: XRF analysis confirming absence of nickel and iron in plating layers and body material.


Electrical Performance

  • Characteristic Impedance: 50Ω ±1Ω

  • Frequency Range: DC–50GHz (2.4mm side)

  • VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.30:1 (40–50GHz)

  • Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)

  • Dielectric Withstanding Voltage: ≥ 500V RMS (at sea level)

  • Insulation Resistance: ≥ 2000 MΩ

  • Contact Resistance: Center ≤ 3.0 mΩ; Outer ≤ 1.5 mΩ

Mechanical Performance

  • Coupling Mechanism: 1/4-36 UNS threaded, hand-tight

  • Recommended Torque: 0.7–0.9 N·m (use non-magnetic torque wrench)

  • Mating Cycles: ≥ 500 (clean environment, proper torque)

  • Retention Force: Axial pull-off ≥ 50 N (mated)

  • Mounting Options: Straight cable, panel-mount, flange-mount

Materials & Structure

  • Body / Shell (Option A): Brass, direct gold-plated — no nickel underplate, no iron

  • Body / Shell (Option B): Non-magnetic stainless steel, passivated — μr ≈ 1.01, Fe content below ferromagnetism threshold

  • Center Contact: Beryllium copper (non-magnetic grade), gold-plated

  • Dielectric: PTFE (Teflon®), virgin grade, no ferromagnetic filler

  • Coupling Nut: Matching body material — brass gold or NM stainless steel

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Cryogenic Operation: Verified to 4K (dilution refrigerator compatible)

  • Magnetic Properties: Residual magnetism quantified per unit; threshold customized per application

  • RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • 1/4-36 UNS Thread — 0.7–0.9 N·m: Use a non-magnetic torque wrench. Standard steel wrenches introduce magnetic fields — strictly prohibited.

  • Cleanroom Handling: At 50GHz, λ/4 ≈ 1.5 mm. Particle contamination at the air-dielectric interface causes measurable VSWR degradation. Clean all mating surfaces with IPA before connection.

  • Material Selection Guidance:

    • Brass Gold (Option A): Best conductivity, lowest insertion loss. For lab environments where maximum RF performance is the priority.

    • NM Stainless Steel (Option B): Maximum corrosion resistance and lowest residual magnetism. For MRI suites, accelerator tunnels, and outdoor quantum facilities.



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

MRI RF Coil

CW-NM-24-24-MF (Brass Au)

No Ni/Fe, lowest loss

3T/7T coil feed

Quantum Cryogenic System

CW-NM-24-24-FF (NM SS)

4K rated, μr quantified

Dilution fridge wall feedthrough

Particle Accelerator

CW-NM-24-292-MF (NM SS)

Radiation + magnetic tolerant

Beamline RF monitor

Precision Metrology Lab

CW-NM-24-35-MF (Brass Au)

50GHz to 3.5mm, certified

National standards lab VNA

5G mmWave Test

CW-NM-24-292-MF

50GHz to 40GHz bridge

OTA chamber interface

Automotive Radar

CW-NM-24-24-MM

76–81GHz capable pair

Radar module validation

SQUID Readout

CW-NM-24-SMP-MF

Blind-mate, non-magnetic

Multi-channel cryogenic array

6G Research

CW-NM-24-185-MF

50GHz to 67GHz

Sub-THz prototyping

Aerospace Calibration

CW-NM-24-N-MF

50GHz to N-Type

Antenna range feed

Medical Imaging R&D

CW-NM-24-SMA-MF

50GHz to SMA

Prototype MRI coil test

Standard Matrix & Extensions

  • Gender Sets: M-M, M/F, F-F in 2.4mm (all non-magnetic)

  • Cross-Series Adapters: 2.4mm ↔ 2.92mm / 3.5mm / SMA / N-Type / 1.85mm / SMP (all genders)

  • Body Material Options: Brass gold-plated (no Ni) / Non-magnetic stainless steel passivated

  • Full Kit: Connector + non-magnetic torque wrench + protective caps + serialized test report

⚡ Electrical Performance Customization

  • Residual Magnetism Threshold: Quantified per customer specification — from "no detectable ferromagnetism" to application-specific μr limits

  • Phase-Matched Sets: Multiple connectors matched for MIMO quantum readout arrays

  • Extended S-Parameter Grid: Custom frequency step resolution for critical band analysis

Structural Customization

  • Custom Flange Patterns: Non-standard hole spacing for legacy cryogenic or accelerator hardware

  • Captive Center Contact: For field-replaceable applications in sealed systems

  • Right-Angle Variants: 90° for constrained cryogenic routing (consult Coaxwave)

️ Material & Environmental Customization

  • Titanium Body: Grade 5 Ti-6Al-4V for ultra-low magnetic susceptibility (μr ≈ 1.0002, special order)

  • High-Purity Alumina Dielectric: For extreme cryogenic thermal conductivity (consult Coaxwave)

  • Heavy Gold Plating: Thick gold for maximum wear resistance in high-mating-cycle lab environments

Service & Support

  • Independent Non-Magnetic Test Report: Every connector ships with residual magnetism quantification + DC–50GHz VNA S-parameter curves

  • Serialized Traceability: Laser-marked serial numbers on connector bodies

  • Rapid Prototyping: Standard 2–3 weeks; custom 4–6 weeks (material certification + magnetism test cycle)

  • Application Engineering: Coaxwave RF engineers provide:

    • Material option guidance (Brass Au vs. NM SS) based on RF loss budget and magnetic field strength

    • Residual magnetism threshold definition based on application sensitivity

    • Cryogenic cable assembly length calculation for 4K installations

    • VNA calibration and de-embedding support for 50GHz measurements


Tip

"There is no perfect standard part, only the most suitable solution."

MRI RF Coil — 3T Scanner, Brass Gold Option

  • Setup: 3T MRI system, transmit/receive head coil. RF feedthrough requires absolute magnetic purity — any ferromagnetic particle causes image artifact. Use CW-NM-24-24-MF (brass gold-plated, no nickel, no iron).

  • Workflow: Connector mounted on coil housing. Internal 2.4mm semi-rigid cable soldered to coil element. External 2.4mm plug hand-tight (0.8 N·m, non-magnetic torque wrench). Magnet room entry — zero image artifact from connector.

  • Why This Connector: Brass gold body has no Ni/Fe. Direct gold plating eliminates nickel barrier layer — the #1 hidden source of residual magnetism in plated connectors. Residual magnetism quantified per unit and certified below MRI-safe threshold.

Quantum Cryogenic System — Dilution Refrigerator, NM SS Option

  • Setup: Superconducting qubit chip at 10mK. Control lines require 50GHz bandwidth for fast pulsing. Use CW-NM-24-24-FF (NM stainless steel, 4-hole flange).

  • Workflow: Connector flange-mounted on refrigerator wall. 2.4mm male on internal cable hand-tight (0.7 N·m, non-magnetic wrench) to flange female. All tools verified non-magnetic. System cooled to base temperature — qubit coherence T2 within specification.

  • Why This Connector: NM stainless steel body verified μr ≈ 1.01. No nickel, no iron. 4K operation confirmed. Full S-parameter report proves 50GHz performance before cool-down.

⚡ Particle Accelerator — Beamline RF Monitor

  • Setup: Synchrotron beamline, RF pick-up monitors track bunch timing at 50GHz. Harsh environment: radiation + strong dipole magnetic fields. Use CW-NM-24-292-MF (NM SS, 2.4mm to 2.92mm).

  • Workflow: 2.4mm male hand-tight on beamline probe. 2.92mm female connected to radiation-hardened cable. Magnetism test report confirms no field perturbation. Radiation tolerance verified per component.

  • Why This Connector: NM stainless steel survives both radiation and magnetic field environments. 2.4mm to 2.92mm bridge adapts to existing 40GHz infrastructure. Residual magnetism quantified against accelerator magnetic field map.

⚠️ Usage Red Lines

  • ⚠️ ABSOLUTELY NO MAGNETIC TOOLS:

    • Standard steel torque wrenches, screwdrivers, and tweezers are FERROMAGNETIC

    • Using a magnetic tool near an MRI scanner or quantum system can cause permanent damage or corrupted data

    • Only non-magnetic stainless steel or brass tools allowed. Coaxwave supplies a non-magnetic torque wrench on request


  • ⚠️ 1/4-36 UNS Torque — 0.7–0.9 N·m:

    • 2.4mm interfaces are precision-machined to micron tolerances. Over-tightening deforms the air-dielectric gap

    • 0.9 N·m is the absolute maximum. Hand-tight until snug is often sufficient


  • ⚠️ Verify Plating Stack Before Installation:

    • Standard 2.4mm connectors often have nickel underplate beneath gold. This connector does NOT

    • If a third-party connector is mixed into the same system, verify its plating stack — one nickel-plated part compromises the entire magnetic purity claim


  • ⚠️ Cryogenic Thermal Contraction:

    • Stainless steel contracts ~0.3% from room temperature to 4K. Brass contracts ~0.2%

    • Account for this in cable assembly length calculations for cryogenic installations



Coaxwave Non-Magnetic 2.4mm Connector · Delivery Commitment

  • Impedance: 50Ω ±1Ω

  • Frequency Range: DC–50GHz

  • VSWR: ≤ 1.25:1 (DC–40GHz); ≤ 1.30:1 (40–50GHz)

  • Coupling: 1/4-36 UNS threaded, 0.7–0.9 N·m

  • Body Options: Brass gold-plated (no Ni) / NM stainless steel passivated (no Fe)

  • Magnetic Properties: Residual magnetism quantified per unit, threshold customized

  • Temperature Range: -55℃ ~ +125℃ (4K cryogenic verified)

  • Adapter Matrix: 2.4mm ↔ 2.4mm / 2.92mm / 3.5mm / SMA / N-Type / 1.85mm / SMP — any A-to-B, all genders

  • 100% Residual Magnetism Test + DC–50GHz VNA S-Parameters + Serialized Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for Non-Magnetic 2.4mm Selection:

  1. Brass Gold vs. NM SS — Choose by Priority: Brass gold for lowest insertion loss. NM stainless steel for lowest residual magnetism and maximum corrosion resistance. Both exclude nickel and iron.

  2. Residual Magnetism Is Quantified, Not Assumed: Every unit ships with a test report. If your application requires a specific μr threshold, state it at order — Coaxwave will certify against it.

  3. Non-Magnetic Tools Are Mandatory: The connector body is only as non-magnetic as the installation tools. One steel wrench invalidates the entire material investment.


There is no perfect standard part, only the most suitable solution.

Coaxwave Non-Magnetic 2.4mm Connectors are engineered interconnects where nickel-free and iron-free material purity, quantified residual magnetism certification, and air-dielectric millimeter-wave architecture deliver the most trusted 50GHz non-magnetic interface for MRI, quantum computing, particle accelerators, and precision metrology. Every connector is DC–50GHz VNA-tested, magnetism-quantified, and cryogenically validated with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning 2.92mm, 3.5mm, SMA, N-Type, 1.85mm, and SMP, Coaxwave delivers the most suitable non-magnetic 2.4mm solution for your exact magnetic sensitivity requirement.

Sales Email: sales@coaxial-rf.com