Coaxwave Precision Open Circuit Standard | 50Ω | DC-18 to 67GHz | N/SMA/3.5/2.92/2.4/1.85mm M-F | Offset Phase Polynomial | 100% VNA Tested | SOL SOLT VNA Calibration
  • Coaxwave Precision Open Circuit Standard | 50Ω | DC-18 to 67GHz | N/SMA/3.5/2.92/2.4/1.85mm M-F | Offset Phase Polynomial | 100% VNA Tested | SOL SOLT VNA Calibration
  • 1/1
  • Coaxwave Precision Open Circuit Standard | 50Ω | DC-18 to 67GHz | N/SMA/3.5/2.92/2.4/1.85mm M-F | Offset Phase Polynomial | 100% VNA Tested | SOL SOLT VNA Calibration

Coaxwave Precision Open Circuit Standard | 50Ω | DC-18 to 67GHz | N/SMA/3.5/2.92/2.4/1.85mm M-F | Offset Phase Polynomial | 100% VNA Tested | SOL SOLT VNA Calibration

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave Precision Open Circuit Standard is the core one-port calibration artifact in RF Test & Measurement, engineered for SOL/SOLT VNA calibration. 50Ω characteristic impedance, establishing the reference plane for known reflection phase and magnitude. Frequency coverage: DC-18GHz (N/SMA), DC-33GHz (3.5mm), DC-40GHz (2.92mm), DC-50GHz (2.4mm), DC-67GHz (1.85mm). Full M/F matrix across all six interfaces. 100% VNA full-band characterized with offset phase polynomial coefficients and measured curves. Independent calibration data manual. The indispensable reflect standard for directivity and source-match error correction in R&D, ATE, aerospace, and metrology.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

The Operating Principle of a Precision Open

In VNA SOLT calibration, the Open standard provides a known reference reflection at approximately 0° phase. Unlike a theoretical perfect open (which would reflect 100% of the signal with zero phase shift), a real coaxial open exhibits fringing capacitance at the dielectric-air boundary and a small phase offset due to the physical break in the transmission line. Coaxwave precision opens are characterized so that this fringing capacitance and phase offset are mathematically modeled using a offset phase polynomial — typically a 3rd- or 5th-order function of frequency. The VNA software uses these coefficients to compute the exact expected reflection coefficient at every frequency point, enabling accurate separation of systematic error terms.

Frequency Coverage by Interface:

Interface

Frequency

Primary Calibration Use

N-Type / SMA

DC-18GHz

General-purpose SOLT, sub-6GHz and C-band

3.5mm

DC-33GHz

Extended K-band SOLT, 5G FR1

2.92mm (K-Type)

DC-40GHz

Ka-band SOLT, SatCom uplink

2.4mm

DC-50GHz

E-band SOLT, 5G FR2

1.85mm (V-Type)

DC-67GHz

V-band SOLT, W-band extension

All Transfer Models (complete open circuit matrix — native & adapter-type):

No.

Model Name

Input Interface

Output (Open Reference)

Freq

Notes

1

CW-OP50-N-M

N-Type (M)

Open reference plane

DC-18GHz

Native, male

2

CW-OP50-N-F

N-Type (F)

Open reference plane

DC-18GHz

Native, female

3

CW-OP50-SMA-M

SMA (M)

Open reference plane

DC-18GHz

Native, male

4

CW-OP50-SMA-F

SMA (F)

Open reference plane

DC-18GHz

Native, female

5

CW-OP50-35-M

3.5mm (M)

Open reference plane

DC-33GHz

Native, male

6

CW-OP50-35-F

3.5mm (F)

Open reference plane

DC-33GHz

Native, female

7

CW-OP50-292-M

2.92mm (M)

Open reference plane

DC-40GHz

Native, male

8

CW-OP50-292-F

2.92mm (F)

Open reference plane

DC-40GHz

Native, female

9

CW-OP50-24-M

2.4mm (M)

Open reference plane

DC-50GHz

Native, male

10

CW-OP50-24-F

2.4mm (F)

Open reference plane

DC-50GHz

Native, female

11

CW-OP50-185-M

1.85mm (M)

Open reference plane

DC-67GHz

Native, male

12

CW-OP50-185-F

1.85mm (F)

Open reference plane

DC-67GHz

Native, female

13

CW-OP50-SMA-35-M

SMA (M) → 3.5mm (F) adapter + open

DC-18GHz

SMA-limited


14

CW-OP50-35-SMA-M

3.5mm (M) → SMA (F) adapter + open

DC-18GHz

SMA-limited


15

CW-OP50-SMA-292-M

SMA (M) → 2.92mm (F) adapter + open

DC-18GHz

SMA-limited


16

CW-OP50-292-SMA-M

2.92mm (M) → SMA (F) adapter + open

DC-18GHz

SMA-limited


17

CW-OP50-35-292-M

3.5mm (M) → 2.92mm (F) adapter + open

DC-33GHz

3.5mm-limited


18

CW-OP50-292-35-M

2.92mm (M) → 3.5mm (F) adapter + open

DC-33GHz

3.5mm-limited


19

CW-OP50-292-24-M

2.92mm (M) → 2.4mm (F) adapter + open

DC-40GHz

2.92mm-limited


20

CW-OP50-24-292-M

2.4mm (M) → 2.92mm (F) adapter + open

DC-40GHz

2.92mm-limited


21

CW-OP50-24-185-M

2.4mm (M) → 1.85mm (F) adapter + open

DC-50GHz

2.4mm-limited


22

CW-OP50-185-24-M

1.85mm (M) → 2.4mm (F) adapter + open

DC-50GHz

2.4mm-limited


💡 Frequency Boundaries for Cross-Interface Models: Always bounded by the lower-rated interface. SMA-based adapters capped at DC-18GHz. 3.5mm-based adapters at DC-33GHz. 2.92mm-based at DC-40GHz. 2.4mm↔1.85mm capped at DC-50GHz (2.4mm limit). For any measurement above the adapter limit, use native open + separate calibration.

Key Performance (independent Coaxwave test system):

  • Reflection Coefficient: Γ ≈ +1 (magnitude ≥ 0.95, decreasing gradually with frequency due to fringing)

  • Offset Phase Polynomial: 3rd-order (standard) or 5th-order (metrology) coefficients provided in factory manual

  • Return Loss (magnitude reference): ≥ 20dB (DC-6GHz); degrades gradually above 6GHz due to fringing capacitance

  • Impedance: 50Ω reference system

Inspection: 100% VNA full-band S11 magnitude and phase sweep + offset phase polynomial extraction + fringing capacitance characterization. Each unit ships with an independent calibration data manual — measured S11 data, polynomial coefficients, and model curves. Laser-marked with unique serial number.

🎯 Core Positioning: The 0° Phase Reference for SOLT Directivity Correction

In SOLT calibration, the Open defines the 0° phase reference against which the VNA measures all other reflections. Coaxwave Precision Opens are not simple "uncovered" connectors — they are calibrated microwave components where the fringing capacitance at the dielectric-air boundary and the physical offset from the reference plane are fully characterized. This enables the VNA to compute directivity and source-match error coefficients with metrology-grade accuracy.

⚡ Offset Phase Polynomial — The Mathematical Foundation

Unlike a fixed short circuit (which has a relatively constant phase near 180°), an open circuit's phase deviates significantly from 0° as frequency increases due to fringing fields at the coaxial aperture. Coaxwave provides offset phase polynomial coefficients (C0, C1, C2, C3, and optionally C4, C5) that model this behavior:

φ(f) = C0 + C1·f + C2·f² + C3·f³ + C4·f⁴ + C5·f⁵

Where φ is the phase offset in degrees and f is frequency in GHz. Entering these coefficients into the VNA calibration kit definition reduces calibration residual error by up to 5× compared to using an "ideal open" model.

🔧 Full Native & Adapter-Type Matrix

Coaxwave provides 12 native models (6 interfaces × M/F) and 10 adapter-type configurations, covering every major cross-interface transition in the RF calibration chain.

Native (interface-to-open, full frequency):

  • N-Type / SMA: DC-18GHz, M/F

  • 3.5mm: DC-33GHz, M/F

  • 2.92mm: DC-40GHz, M/F

  • 2.4mm: DC-50GHz, M/F

  • 1.85mm: DC-67GHz, M/F

Adapter-Type (via precision transition, frequency bounded by opposite interface):

  • SMA ↔ 3.5mm: DC-18GHz (SMA-limited)

  • SMA ↔ 2.92mm: DC-18GHz (SMA-limited)

  • 3.5mm ↔ 2.92mm: DC-33GHz (3.5mm-limited)

  • 2.92mm ↔ 2.4mm: DC-40GHz (2.92mm-limited)

  • 2.4mm ↔ 1.85mm: DC-50GHz (2.4mm-limited)

🛡️ Coaxwave Quality Barrier

Every open undergoes three mandatory 100% tests:

  1. VNA Full-Band S11 Magnitude & Phase Sweep: Reflection coefficient measured from DC to the interface's rated frequency. Phase deviation from 0° extracted at every frequency point.

  2. Fringing Capacitance Characterization: Equivalent parallel capacitance at the aperture measured and modeled into the polynomial coefficients.

  3. Mechanical Gauge Verification: Mating depth and center conductor position checked against IEEE 287 / MIL-STD-348 gauge standards.

No sampling, no "typical" curves. Each unit ships with an independent calibration data manual — your unit's actual S11 data, polynomial coefficients, and gauge compliance. Laser-marked serial number guarantees full traceability.


Electrical Performance

  • Reflection Coefficient (Γ): ≈ +1 (magnitude ≥ 0.95, decreasing with frequency due to fringing)

  • Offset Phase Polynomial: 3rd-order standard; 5th-order optional (metrology)

  • Return Loss: ≥ 20dB reference at low frequencies; degrades gradually above 6GHz per fringing model

  • Frequency Range:

    • N-Type / SMA: DC-18GHz

    • 3.5mm: DC-33GHz

    • 2.92mm: DC-40GHz

    • 2.4mm: DC-50GHz

    • 1.85mm: DC-67GHz

    • Adapter-type: Bounded by lower-rated interface


Mechanical Performance

  • Connector Interfaces: Per IEEE Std 287™-2007 (1.85/2.4/3.5/2.92mm) and MIL-STD-348 (SMA/N-Type)

  • Mating Cycles: ≥ 500 (all precision interfaces)

  • Coupling Torque:

    • SMA / 3.5mm / N-Type: 0.9 N·m (8 in-lbs)

    • 2.92mm: 0.8–1.1 N·m (7.1–9.7 in-lbs)

    • 2.4mm / 1.85mm: 0.45 N·m (4 in-lbs)


  • Center Contact: Beryllium copper, gold-plated over nickel underplating

  • Open Aperture: Precision-machined dielectric break with controlled fringing geometry

  • Mounting: Inline only (calibration standard, not panel-mount)

Materials & Structure

  • Housing / Outer Conductor: Passivated stainless steel (SUS303)

  • Inner Conductor: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PTFE (SMA/N/3.5mm) or PEI (2.92mm/2.4mm/1.85mm) with precision air-gap transition at aperture

  • Interface Standard: IEEE 287 / MIL-STD-348 per interface

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • SOLT Calibration Use:

    • Connect open to VNA port as the second step in SOLT (after Short)

    • Enter the polynomial coefficients from the factory manual into the VNA calibration kit definition

    • The VNA uses the coefficients to compute expected S11 at every frequency point


  • Cross-Interface Use:

    • When using adapter-type opens, calibrate at the adapter's output interface

    • Frequency is bounded by the lower-rated side


  • Handling:

    • 100% VNA phase tested — independent calibration data manual ships with every unit

    • Keep the open aperture clean and dry — dust or moisture at the aperture changes fringing capacitance → calibration error

    • Cap when not in use — the open aperture must be protected from contamination



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

5G FR1 ATE

CW-OP50-SMA-M

DC-18GHz, polynomial model

5G sub-6GHz antenna test

Aerospace L-band

CW-OP50-N-M

DC-18GHz, rugged

Avionics T/R module calibration

5G FR2 E-band

CW-OP50-24-M

DC-50GHz, 5th-order poly

5G mmWave OTA calibration

SatCom Ka-band

CW-OP50-292-M

DC-40GHz, 3rd-order poly

SatCom HPA calibration

Automotive Radar (77GHz)

CW-OP50-185-M

DC-67GHz, 5th-order poly

V-band radar module test

Production ATE

CW-OP50-SMA-F

DC-18GHz, 500+ cycles

High-throughput device test

Legacy 3.5mm VNA

CW-OP50-35-SMA-M

3.5mm-to-SMA, DC-18GHz

Extend 3.5mm VNA to SMA DUT

2.92mm to 2.4mm DUT

CW-OP50-292-24-M

2.92mm-to-2.4mm, DC-40GHz

Cross-interface SOLT

Defense EW System

CW-OP50-292-F

DC-40GHz, rugged

EW receiver calibration

Metrology Lab

CW-OP50-185-M

DC-67GHz, 5th-order poly

National-lab V-band calibration

Standard Matrix & Extensions

  • Six Interfaces: N-Type, SMA, 3.5mm, 2.92mm, 2.4mm, 1.85mm — M/F each

  • Full Cross-Interface Adapter Matrix: 10 standard models

  • Polynomial Order: 3rd-order (standard), 5th-order (metrology) — selectable at order

⚡ Electrical Performance Customization

  • 5th-Order Polynomial (Metrology): For national labs requiring highest phase accuracy above 40GHz

  • 75Ω Version: For broadcast/video and CATV calibration

  • Phase-Matched Pairs: Two opens matched for differential/multi-channel systems

Structural Customization

  • Panel-Mount Version: For semi-permanent calibration reference planes in ATE fixtures

  • Captive Center Contact: For high-vibration environments

  • Keyed Coupling Nut: Prevents mis-mating in confined test bays

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum computing RF test

  • Hermetically Sealed Aperture Cover: Removable protective cap with known electrical effect characterization

  • Extended Temperature: For thermal chamber calibration

Service & Support

  • 100% VNA Full-Band Phase Test: S11 magnitude and phase from DC to rated frequency

  • Polynomial Coefficient Data: C0-C5 values in factory calibration manual

  • Independent Calibration Data Manual: Actual S11 data, coefficients, and model curves

  • SN Traceability: Laser-marked unique serial number

  • Rapid Prototyping: Standard models 1-2 week shipment; custom 3-4 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • SOLT calibration kit definition support (polynomial entry guidance)

    • Cross-interface calibration plane management

    • Open aperture care and maintenance best practices

    • Torque and handling best practices per interface


Tip

"There is no perfect standard part, only the most suitable solution."


SOLT Calibration (Same-Interface)

  • Standard SOLT Open Step:
    Use CW-OP50-[IF]-M (native male open) as the Open standard in a SOLT calibration. Connect to VNA Port A after the Short step. Enter the polynomial coefficients from the factory manual into the VNA's calibration kit definition. The VNA computes the expected reflection at every frequency point using the polynomial model.

  • Female Open for Reverse Calibration:
    Use CW-OP50-[IF]-F when calibrating a test cable or fixture that presents a female connector to the VNA port. This eliminates the need for an additional gender-changer adapter.

Cross-Interface Calibration

  • SMA VNA to 3.5mm DUT (DC-18GHz):
    Use CW-OP50-SMA-35-M. Connect SMA side to VNA. Calibrate at the 3.5mm output plane. Frequency limited to DC-18GHz by SMA.

  • 2.4mm VNA to 1.85mm DUT (DC-50GHz):
    Use CW-OP50-24-185-M. Connect 2.4mm side to VNA. Calibrate at 1.85mm plane. Full DC-50GHz coverage. Essential for testing V-band devices on 2.4mm VNAs.

Production ATE

  • High-Volume Device Test:
    Use CW-OP50-SMA-F in automated calibration fixtures. 500+ mating cycles support high-throughput production. The characterized polynomial model ensures consistent calibration across all test sites.

⚠️ Usage Red Lines

  • Torque Each Interface to Specification:

    • SMA/N/3.5mm: 0.9 N·m; 2.92mm: 0.8–1.1 N·m; 2.4mm/1.85mm: 0.45 N·m

    • Under-tightening causes contact resistance variation → phase error

    • Over-tightening deforms precision interfaces → reference plane shifts


  • ⚠️ Cross-Interface Frequency Boundaries Are Absolute:

    • SMA-based adapters capped at DC-18GHz

    • 3.5mm-based adapters capped at DC-33GHz

    • 2.92mm-based adapters capped at DC-40GHz

    • 2.4mm↔1.85mm capped at DC-50GHz


  • Always Enter Polynomial Coefficients into VNA Software:

    • Never select "Ideal Open" if you have characterized polynomial data

    • The coefficients in your factory manual are YOUR unit's actual data — entering them reduces calibration residual error by up to 5×


  • Protect the Open Aperture:

    • Dust, oil, or moisture at the aperture changes fringing capacitance → calibration error

    • Always cap the open when not in use; clean with dry air or lint-free swab if contaminated



Coaxwave Precision Open Circuit Standard · Delivery Commitment

  • Reflection Coefficient: Γ ≈ +1 (magnitude ≥ 0.95, fringing-modeled)

  • Offset Phase Polynomial: 3rd-order standard; 5th-order metrology optional

  • Frequency Coverage: DC-18GHz (N/SMA) → DC-33GHz (3.5mm) → DC-40GHz (2.92mm) → DC-50GHz (2.4mm) → DC-67GHz (1.85mm)

  • Configurations: 12 native models + 10 adapter models = 22 standard transfer models

  • Materials: Passivated stainless steel + BeCu gold-plated contacts + precision dielectric break

  • 100% VNA Full-Band Phase Test + Polynomial Extraction + Mechanical Gauge + Independent Calibration Data Manual + SN Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for Open Selection:

  1. An Open is NOT "Nothing Connected": A bare unmated connector is NOT a calibration standard. The fringing capacitance at the dielectric-air boundary must be characterized. Coaxwave opens provide the mathematical model (polynomial coefficients) that lets the VNA account for this effect.

  2. Always Use the Polynomial Data: If your VNA supports offset-delay or polynomial entry for opens, ALWAYS use the Coaxwave-provided coefficients. Using "ideal open" discards the characterization data and increases calibration uncertainty — especially above 10GHz where fringing becomes significant.

  3. The Open Aperture is Delicate: Unlike a short or load, the open has an exposed precision gap. Contamination here directly changes the fringing capacitance. Cap it when not in use. Never touch the center conductor. Clean with dry air only — no solvents at the aperture.


There is no perfect standard part, only the most suitable solution.

Coaxwave Precision Open Circuit Standards are not merely uncovered connectors; they are the engineered 0° phase reference for SOL/SOLT VNA calibration from DC to 67GHz. We machine every passivated stainless-steel body with "German precision" and characterize every unit's fringing model with "French engineering logic". With six interfaces, male/female genders, a complete cross-interface adapter matrix, and 100% VNA certification, Coaxwave delivers the most suitable open standard for your exact SOLT, production ATE, and metrology requirement.