2.92mm (K-Type) Connector Manufacturing Process: Precision Machining, Air Dielectric and 40GHz Verification

Outer Conductor 2.92mm, Center 1.27mm, 50Ω Air/PEI Interface — Coaxwave Engineering Note on K Connec

2026-09-14 21:24 coaxwave
1

1. Interface Baseline and Electrical Targets

The 2.92mm K-type connector is a 50Ω precision coaxial interface designed for mode-free operation up to 40GHz. The reference geometry uses an outer conductor inner diameter of 2.92mm and a center conductor diameter of approximately 1.27mm; the air-line section is tuned for 50Ω, while dielectric support rings are used only where mechanical centering is required.

Typical specification targets for a precision K connector:

Parameter

Typical value

Impedance

50Ω

Frequency range

DC–40GHz (standard air/PEI version)

VSWR

≤1.10:1 DC–18GHz, ≤1.15:1 18–40GHz for precision grade

Center contact resistance

≤3.0mΩ

Outer contact resistance

≤2.0mΩ

Insulation resistance

≥5000MΩ

Dielectric withstanding

750VRMS max, sea level (model dependent)

Mating cycles

≥500

Coupling torque

0.8–1.1N·m (7–10in·lb)

Operating temperature

-55°C to +135°C or +165°C depending on body/dielectric


The smaller outer diameter versus SMA/3.5mm raises the higher-order-mode cutoff, which is the reason K connectors are used in 40GHz test links rather than standard PTFE-filled SMA.

2. Body Machining and Dimensional Control

Outer conductor / nut / flange

Stainless steel or brass bar stock is turned on CNC lathes to the 2.92mm inner diameter, 1/4-36UNS coupling thread, reference plane, flange boss and bulkhead step. Stainless bodies are usually passivated; brass bodies may be nickel- or gold-plated depending on RF loss, solderability and corrosion requirements. K bodies use thicker walls than standard SMA to reduce thread deformation under torque.

Center contact

Plug pins are shortened relative to SMA so the outer conductors align before the center pin enters the socket; this reduces bent-pin and off-axis damage during blind or high-cycle mating.  Socket contacts are usually beryllium copper with slotted or multi-slot elasticity for stable normal force.

Critical dimensions

Outer inner diameter, center diameter, pin protrusion, socket depth, thread pitch diameter, concentricity and surface roughness are controlled by gauge, air metering or optical measurement. Any oversize/undersize in the 2.92mm/1.27mm region shifts characteristic impedance and appears directly as high-frequency VSWR.

3. Materials and Surface Treatment

Part

Common material

Finish

Purpose

Body/nut/flange

Stainless steel 303/304 or brass

Passivation, nickel or gold

Mechanical stability, corrosion resistance, low RF loss

Plug center pin

Brass or beryllium copper

Gold plating, often ≥50μin

Low contact resistance, wear resistance

Socket contact

Beryllium copper

Gold plating per MIL-G-45204 where specified

Elastic contact, low and stable resistance

Dielectric support

Air, PEI, Ultem, Kapton or limited PTFE

—

Centering with minimum dielectric loss

Gasket/seal

Silicone rubber

—

Environmental sealing for panel/hermetic builds


Air-dielectric interfaces give the best 40GHz behavior. PEI/Ultem or Kapton supports are used when cable/PCB termination requires fixed centering; full PTFE fills are avoided in the mating plane of precision 40GHz versions because PTFE increases dielectric loss and lowers mode-free frequency.

4. Dielectric Support and Impedance Continuity

A K connector is not qualified only by “making it 2.92mm”. The return loss is governed by the transition from air line to support bead, then to cable dielectric or PCB transmission line.

  • Mating interface: 2.92mm outer / 1.27mm center / air εr≈1 → 50Ω reference.

  • Support bead: use thin PEI/Ultem/Kapton rings; keep bead length short and step impedance simulated. For 40GHz, support-induced capacitance must be minimized.

  • Cable transition: semi-rigid RG-405/0.086″, 0.141″ or low-loss flexible cable requires controlled strip length, inner pin depth and 360° outer-ground contact. PTFE-tapered or air-core cable sections reduce high-frequency loss.

  • PCB launcher: end-launch or vertical through-hole microstrip/CPW must match board εr, conductor width and ground via count. Poor via return path is a common source of 30–40GHz VSWR rise.

5. Cable and PCB Assembly Process

Semi-rigid / conformable cable

  1. Strip jacket, outer braid, dielectric and center according to the K plug drawing.

  2. Crimp or solder outer conductor to the connector body; ensure full circumferential RF ground.

  3. Insert center conductor into the pin/socket contact; use a fixture to control depth and concentricity.

  4. Solder with controlled temperature; remove flux residue. Do not allow solder or PTFE debris into the dielectric gap.

  5. Torque the coupling nut to 0.8–1.1N·m using a calibrated wrench; do not hand-tighten on 40GHz links.

PCB receptacle / end-launch

  • Define land pattern, ground pads, anti-pad and via fence from the 2.92mm interface dimensions.

  • For microstrip launchers, match the board thickness and εr to the target 50Ω line; for CPW, keep ground coplanarity and via spacing tight at 40GHz.

  • Reflow or solder the receptacle with controlled profile; inspect center/socket alignment under microscope.

  • Panel mounts should use flatness control; flange bolt torque uniformity avoids mechanical tilt that shifts the center contact.

6. Cross-Mating Rules

K connectors share 1/4-36UNS thread geometry with SMA and 3.5mm, so they can be mechanically mated, but electrical performance is limited by the weakest interface.

Mating pair

Mechanical

Practical RF limit

Note

2.92mm – 2.92mm

Yes

Full 40GHz

Preferred for precision links

2.92mm – 3.5mm

Yes

Limited to 3.5mm bandwidth, commonly up to 26.5GHz

Discontinuity at mixed interface

2.92mm – SMA

Yes

Limited to SMA bandwidth, commonly up to 18GHz

PTFE-filled SMA adds reflection; long SMA pins can damage K sockets


For VNA ports and calibration, use K-to-K or qualified adapters only. When SMA instruments must connect to a K test bench, insert a sacrificial connector saver and document the added loss/return-loss uncertainty.

7. Electrical Verification

VNA setup

  • Instrument calibrated to at least 40GHz using K-calibration standards (SOLT or manufacturer-recommended kit).

  • Two-port calibration for through assemblies; one-port calibration for return-loss-only checks.

  • Sweep 100MHz–40GHz, 801–1601 points, IF bandwidth 1–10kHz depending on noise floor.

  • Record S11/S22 as VSWR or return loss and S21 as insertion loss.

Acceptance logic

  • Single connector or adapter: compare measured VSWR with the grade target, e.g. ≤1.10 DC–18GHz and ≤1.15 18–40GHz for precision parts.  Commercial cable connectors may be specified looser; state the limit used.

  • Cable assembly: review S21 slope, identify solder/joint loss, and separate connector loss from cable loss by through-removed or TRL de-embedding where available.

  • Repeatability: mate/unmate 5–10 times, monitor S11 drift; excess drift indicates pin/socket wear, contamination or torque inconsistency.

  • Environmental samples: thermal cycling, humidity, salt mist or vibration per project specification; retest S-parameters before and after.

8. Process Risks and Controls

  • Oversized/undersized air line: causes broadband or resonant VSWR; control with first-article gauging.

  • PTFE in mating plane: increases loss and high-frequency reflection; restrict to controlled support beads.

  • Hand tightening: produces variable torque and repeatability errors; always use calibrated torque tools.

  • SMA cross-use on precision K ports: accelerates thread wear and raises return loss above 18GHz; use protectors/adapters.

  • PCB via discontinuity: dominates mmWave return loss; simulate launcher before production.

9. Typical Applications

  • 5G FR2 and mmWave test fixtures, up to 40GHz component characterization

  • VNA calibration extensions, cable assemblies and rack interconnects

  • Radar IF/RF modules and SATCOM transceiver panels

  • Aerospace and laboratory metrology requiring repeatable 50Ω interfaces

Coaxwave supplies standard 2.92mm K plugs, jacks, bulkhead, flange and cable assemblies, plus customized launchers and calibration-grade adapters. All production units are verified against the ordered frequency, VSWR and torque specification rather than against a generic catalog wattage.

There is no perfect standard part, only the most suitable solution. For 40GHz K-type interconnection, Coaxwave selects body material, dielectric support, cable stack and PCB launcher from the actual test budget, not from a one-size-fits-all table.


📧 Technical Inquiry: sales@coaxial-rf.com

🌐 Learn More: www.coaxial-rf.com