Architecture — Safety-First High Voltage
Attribute | 20kV High-Voltage Specification |
|---|---|
Rated Voltage | 20kV DC / 15kV AC |
Characteristic Impedance | 50Ω ±2Ω |
Dielectric Options | PE (polyethylene, economy) or PE-X (cross-linked polyethylene, high temp) |
Shield | Tinned copper braid, ≥90% coverage |
Jacket | PUR (polyurethane, flexible) or PVC (economical) |
Insulator (Connector) | PTFE (Teflon®), recessed contact |
Operating Temperature | -55℃ ~ +85℃ |
Hi-Pot Test (Factory) | 41kV DC / 60 seconds, 100% |
All Transfer Models (complete 20kV high-voltage connector matrix — type × gender × mounting):
No. | Model Name | Connector Type | Gender | Mounting | Voltage | Notes |
|---|---|---|---|---|---|---|
1 | CW-HV20-SHV-M-STR | SHV | Male | Straight free | 20kV DC | Standard HV test port |
2 | CW-HV20-SHV-F-STR | SHV | Female | Straight free | 20kV DC | DUT-side SHV |
3 | CW-HV20-SHV-F-BLK | SHV | Female | Bulkhead | 20kV DC | Panel feedthrough |
4 | CW-HV20-MHV-M-STR | MHV | Male | Straight free | 5kV DC* | Legacy HV equipment |
5 | CW-HV20-MHV-F-STR | MHV | Female | Straight free | 5kV DC* | Legacy HV DUT |
6 | CW-HV20-MHV-F-BLK | MHV | Female | Bulkhead | 5kV DC* | Panel mount MHV |
7 | CW-HV20-HC51-M-STR | HC51 | Male | Straight free | 20kV DC | High-current HV |
8 | CW-HV20-HC51-F-STR | HC51 | Female | Straight free | 20kV DC | HC51 DUT side |
9 | CW-HV20-HC52-M-STR | HC52 | Male | Straight free | 20kV DC | Compact 20kV |
10 | CW-HV20-HC52-F-STR | HC52 | Female | Straight free | 20kV DC | HC52 module side |
11 | CW-HV20-DED-M-STR | 20kV Dedicated | Male | Straight free | 20kV DC | Coaxwave proprietary |
12 | CW-HV20-DED-F-STR | 20kV Dedicated | Female | Straight free | 20kV DC | Coaxwave proprietary |
13 | CW-HV20-DED-M-RA | 20kV Dedicated | Male | Right-angle | 20kV DC | Space-constrained HV |
14 | CW-HV20-DED-F-BLK | 20kV Dedicated | Female | Bulkhead | 20kV DC | HV panel feedthrough |
15 | CW-HV20-DED-M-2HF | 20kV Dedicated | Male | 2-hole flange | 20kV DC | Chassis mount HV |
* MHV rated to 5kV DC per IEC 61169-38. SHV, HC51, HC52, and 20kV Dedicated all rated to 20kV DC.
💡 All 15 configurations share the same 20kV cable platform. Two dielectric options: PE (lower cost, -40℃ to +80℃) and PE-X (higher temp, -55℃ to +85℃). Jacket options: PUR (abrasion-resistant, flexible) or PVC (economical). Every assembly is 100% hi-pot tested at 41kV DC for 60 seconds before shipment.
Key Performance (Coaxwave high-voltage specification):
Rated Voltage: 20kV DC / 15kV AC (continuous, at sea level, 25℃ ambient)
Test Voltage (Hi-Pot): 41kV DC / 60s, 100% per assembly
Insulation Resistance: > 10,000 MΩ·km at 500V DC
Partial Discharge: < 5 pC at 12kV DC (typical, PE-X dielectric)
Impedance: 50Ω ±2Ω (designed for pulse and RF-HV hybrid applications)
Capacitance: ~100 pF/m (typical, PE dielectric)
Inspection: 100% hi-pot test (41kV DC / 60s) + insulation resistance measurement + partial discharge test (PE-X grade) + shield continuity verification. Each assembly ships with an individual test certificate — your cable's actual hi-pot pass record, insulation resistance value, and partial discharge level. Laser-marked serial numbers guarantee full traceability.
Standard RF connectors (SMA, N-Type, BNC) are not rated for high-voltage DC or AC applications. Even MHV (5kV) and SHV (20kV) have limitations when the application demands both high voltage and a 50Ω environment for pulse fidelity. Coaxwave 20kV High-Voltage Coaxial Cable Assemblies close this gap with a purpose-built cable and connector system. The recessed contact design means the center pin is never exposed — a critical safety feature in medical X-ray, electrostatic discharge, and nuclear instrumentation environments.
20kV Dedicated Series (Coaxwave Proprietary):
Male/Female Straight (CW-HV20-DED-M/F-STR): The primary 20kV interconnect. Recessed center contact, PTFE insulator, 41kV DC hi-pot verified. For medical imaging systems, radar modulators, and ESD test equipment.
Male Right-Angle (CW-HV20-DED-M-RA): 90° exit for space-constrained HV routing inside equipment racks.
Female Bulkhead (CW-HV20-DED-F-BLK): Panel feedthrough for HV power entry into shielded enclosures.
Male 2-Hole Flange (CW-HV20-DED-M-2HF): Chassis-mounted HV port for permanent equipment installation.
SHV Series (20kV Standard):
SHV Male/Female (CW-HV20-SHV-M/F-STR): Industry-standard 20kV HV connector per IEC 61169-38. Safe, recessed contact. Compatible with all SHV-equipped test equipment.
SHV Female Bulkhead (CW-HV20-SHV-F-BLK): Panel-mount SHV for HV instrumentation front panels.
MHV Series (5kV Legacy):
MHV Male/Female (CW-HV20-MHV-M/F-STR): For legacy HV equipment rated to 5kV DC. Not for 20kV use — clearly marked.
MHV Female Bulkhead (CW-HV20-MHV-F-BLK): Panel-mount MHV for older systems.
HC51 / HC52 Series (20kV High-Current):
HC51 Male/Female (CW-HV20-HC51-M/F-STR): High-current 20kV connector. Larger center contact for applications requiring both high voltage and higher current (e.g., capacitor bank discharge).
HC52 Male/Female (CW-HV20-HC52-M/F-STR): Compact 20kV connector. Smaller footprint than HC51, same 20kV rating. For dense HV module layouts.
Every 20kV High-Voltage Coaxial Cable Assembly undergoes four mandatory 100% controls:
41kV DC Hi-Pot Test (60 seconds): Every assembly is subjected to 41kV DC for 60 seconds. No breakdown, no flashover, no leakage current exceeding 1 μA. This is 2× the rated operating voltage — a safety margin built into every cable.
Insulation Resistance Test: > 10,000 MΩ·km measured at 500V DC. Confirms dielectric integrity along the entire cable length.
Partial Discharge Test (PE-X grade only): < 5 pC extinction voltage at 12kV DC. Ensures no internal voids or micro-discharges that could degrade the dielectric over time.
Shield Continuity & Integrity: Copper braid checked for 100% coverage and low DC resistance to ground.
Each assembly ships with an individual test certificate — your cable's hi-pot pass record, insulation resistance value, and partial discharge data (where applicable). Laser-marked serial numbers on every connector guarantee full traceability.
Rated Voltage: 20kV DC / 15kV AC continuous (at sea level, 25℃ ambient)
Test Voltage (Hi-Pot): 41kV DC / 60 seconds (100% factory test)
Impedance: 50Ω ±2Ω
Insulation Resistance: > 10,000 MΩ·km at 500V DC
Partial Discharge Extinction: < 5 pC at 12kV DC (PE-X grade)
Capacitance: ~100 pF/m (PE), ~90 pF/m (PE-X)
Cutoff Frequency: ~1 GHz (cable limited; connector limited to lower of rated frequency)
Cable Outer Diameter: ~7.0 mm (typical, depending on dielectric and jacket)
Minimum Bend Radius: 10× OD (static), 15× OD (dynamic)
Connector Coupling: Threaded (SHV: 1/4-28 UNS modified; MHV: 3/8-32 UNEF; HC51/HC52: M8×1.0; 20kV Dedicated: M10×1.0)
Torque: SHV: 0.8 N·m; MHV: 0.6 N·m; HC51/HC52: 1.0 N·m; 20kV Dedicated: 1.2 N·m
Mating Cycles: ≥ 500 (all connector types)
Contact Retention: Center contact recessed ≥ 3 mm inside insulator (unmated state)
Inner Conductor: Tinned copper or silver-plated copper, solid or stranded
Dielectric: PE (polyethylene) or PE-X (cross-linked polyethylene)
Shield: Tinned copper braid, ≥90% coverage
Outer Jacket: PUR (polyurethane) or PVC
Connector Insulator: PTFE (Teflon®), recessed contact cavity
Connector Body: Brass, nickel-plated or passivated stainless steel
Operating Temperature: -55℃ ~ +85℃ (PE-X + PUR); -40℃ ~ +80℃ (PE + PVC)
Storage Temperature: -65℃ ~ +85℃
Flame Rating: UL VW-1 (PVC jacket); UL 94 V-0 (PUR jacket)
RoHS / REACH: Compliant
Quality System: ISO 9001:2015 / AS9100D
⚠️ CRITICAL SAFETY: Never Mate or De-mate Under Voltage:
High-voltage connectors must ONLY be engaged or disengaged when the system is fully de-energized and safely discharged
Always verify zero voltage with a certified HV probe before handling
Connector Torque:
Use the specified torque wrench for each connector type
Do NOT over-tighten — excessive torque can crack the PTFE insulator, exposing the high-voltage contact
Do NOT under-tighten — loose coupling increases contact resistance → localized heating → potential flashover
Bend Radius:
Respect minimum bend radius: 10× OD static, 15× OD dynamic
Never kink — sharp bends stretch the copper braid and thin the dielectric wall → HV breakdown risk
Routing:
Maintain minimum 50 mm clearance from other low-voltage signal cables
Use ceramic or non-conductive cable clamps — never use metal ties
Route away from sharp edges that could nick the jacket
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
Medical X-Ray / CT | CW-HV20-DED-M-STR | 20kV dedicated, recessed contact | High-voltage X-ray tube feed |
MRI Gradient Amp | CW-HV20-SHV-M-STR | SHV standard, 20kV | Gradient coil driver |
Radar Transmitter | CW-HV20-HC51-M-STR | HC51 high-current, 20kV | Modulator to magnetron |
ESD Test System | CW-HV20-DED-M-RA | 20kV RA, space save | ESD simulator output |
Nuclear Instrumentation | CW-HV20-DED-F-BLK | 20kV bulkhead | Radiation detector HV bias |
Capacitor Bank Discharge | CW-HV20-HC52-F-STR | HC52 compact, 20kV | Pulse discharge line |
High-Voltage Lab | CW-HV20-SHV-F-BLK | SHV bulkhead, safe | Lab bench HV distribution |
Legacy HV Equipment | CW-HV20-MHV-M-STR | MHV 5kV | Older HV test sets |
Particle Accelerator | CW-HV20-DED-M-2HF | 20kV 2HF flange | Beamline HV feed |
Industrial Electrostatic | CW-HV20-DED-F-STR | 20kV female | Ionizer bar feed |
Connector Types: 20kV Dedicated, SHV, MHV, HC51, HC52 — all genders and mountings
Cable Options: PE dielectric + PVC jacket (economy) or PE-X dielectric + PUR jacket (high-performance)
Lengths: 0.5 m to 30 m (standard); custom lengths available
Full Kit: Cable assembly + test certificate + torque wrench (connector-specific) + HV safety caps
Higher Test Voltage: 50kV DC / 60s available on request (special dielectric)
Partial Discharge Optimization: Custom PE-X formulation for < 2 pC at 15kV DC
Triaxial Version: Outer shield + inner HV coax for guarded HV measurements
Right-Angle at Either End: 90° 20kV dedicated or SHV for panel-edge routing
Bulkhead with HV Interlock: Integrated microswitch that disconnects HV when bulkhead is opened
Custom Strain Relief: Overmolded HV-rated boots at connector-cable junction
Oil-Resistant Jacket: Special PUR compound for oil-filled transformer environments
Flame-Retardant Jacket: Low-smoke zero-halogen (LSZH) for indoor HV installations
Extended Temperature: PE-X + silicone rubber jacket for +125℃ short-term excursion
100% 41kV Hi-Pot Test: Every assembly tested before shipment
Individual Test Certificate: Hi-pot pass, insulation resistance, partial discharge data
SN Traceability: Laser-marked unique serial numbers on every connector
Rapid Prototyping: Standard configurations 2–3 week shipment; custom 4–6 weeks
Application Engineering: Coaxwave RF engineers provide:
Voltage derating guidance for altitude and temperature
Connector type selection (SHV vs. HC51 vs. 20kV Dedicated)
HV safety and clearance recommendations
Partial discharge testing strategy for medical/nuclear compliance
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: X-ray tube requires 20kV DC bias from the high-voltage power supply. Use CW-HV20-DED-M-STR (2 m, PE-X + PUR).
Workflow: Mount power supply HV output to system chassis. Route cable with 10× OD bend radius. Connect 20kV dedicated male to supply, torque to 1.2 N·m. Connect female to X-ray tube. Before energizing, verify all connections are tight and insulated. Power on — system operates at 18kV DC. No corona, no leakage.
Why This Cable: Recessed contact prevents accidental shock during maintenance. 41kV hi-pot tested for safety margin. PE-X dielectric handles continuous 18kV with < 5 pC partial discharge.
Setup: Radar modulator drives a magnetron at 20kV DC, 5A pulse. Use CW-HV20-HC51-M-STR (1.5 m, PE-X + PUR).
Workflow: Connect HC51 male to modulator output, torque to 1.0 N·m. Route cable away from low-voltage control lines (≥ 50 mm clearance). Connect HC51 female to magnetron. Run hi-pot verification at system level. Fire radar pulse — clean pulse shape, no ringing.
Why This Cable: HC51's larger center contact handles the pulse current without excessive voltage drop. 50Ω impedance maintains pulse fidelity. 20kV rating matches modulator output.
Setup: ESD test system requires 20kV output cable with right-angle exit. Use CW-HV20-DED-M-RA (1 m, PE + PVC).
Workflow: Connect RA male to ESD simulator output, torque to 1.2 N·m. Route cable along test bench edge. Connect female to ESD gun or discharge tip. Run 41kV hi-pot self-test. Perform ESD discharge at 15kV — no arcing on cable.
Why This Cable: Right-angle exit fits compact ESD test bench. Recessed contact on female end prevents accidental discharge to nearby metal. 41kV test ensures safety margin above 15kV operating level.
⚠️ NEVER MATE OR DE-MATE UNDER VOLTAGE — FATAL RISK:
High-voltage connectors MUST be de-energized and discharged before handling
Always verify zero voltage with a certified HV probe
This is not a hot-swap system. Ignored warnings result in severe injury or death.
⚠️ Voltage Derating at Altitude and Temperature:
20kV DC rating is at sea level, 25℃. At 2000m altitude, derate to 15kV. At 50℃, derate to 14kV.
Always consult Coaxwave derating chart for your operating environment.
⚠️ SHV and MHV Are NOT Interchangeable:
SHV: 20kV DC. MHV: 5kV DC. They look similar but have different center pin diameters.
Never force an MHV plug into an SHV jack — the center pin will not seat properly, creating an arc risk.
⚠️ Minimum Bend Radius Is Absolute — HV Breakdown Risk:
10× OD static, 15× OD dynamic. Sharp bends thin the dielectric wall locally.
A kinked 20kV cable is a failure waiting to happen. Route with gradual curves only.
Rated Voltage: 20kV DC / 15kV AC (continuous, sea level, 25℃)
Hi-Pot Test: 41kV DC / 60 seconds, 100% per assembly
Impedance: 50Ω ±2Ω
Connector Matrix: 20kV Dedicated, SHV, MHV, HC51, HC52 (all genders, straight/RA/bulkhead/flange)
Cable Options: PE + PVC (economy) or PE-X + PUR (high-performance)
Safety Feature: Recessed live contact design on all 20kV-rated connectors
100% 41kV Hi-Pot + Insulation Resistance + Partial Discharge (PE-X) + Shield Continuity + Individual Test Certificate + SN Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for 20kV HV Cable Selection:
41kV Hi-Pot Is 2× the Rated Voltage — By Design: Every Coaxwave 20kV assembly is tested at 41kV DC for 60 seconds. This is not a sample test; it is 100% per cable. Your safety margin is built in from day one.
Recessed Contact Is a Safety Feature, Not a Convenience: The center contact is set deep inside the insulator. When unmated, no metal is accessible. This protects service personnel during maintenance. Never modify or file down the insulator to "improve contact" — this voids the safety certification.
MHV Is 5kV Maximum — Never Use for 20kV: MHV connectors are included in the matrix for legacy system support ONLY. They are rated to 5kV DC per IEC 61169-38. For any application above 5kV, use SHV, HC51, HC52, or 20kV Dedicated. Mixing MHV into a 20kV system is a critical safety violation.
There is no perfect standard part, only the most suitable solution.
Coaxwave 20kV High-Voltage Coaxial Cable Assemblies are not merely thick cables with oversized connectors — they are safety-engineered subsystems where the recessed contact design, 41kV hi-pot verification, and partial discharge control work together to protect both the system and the operator. Every bend radius is specified, every dielectric is validated with "German precision" and "French engineering logic", and every assembly ships with full SN traceability and a test certificate. With fifteen standard configurations covering every high-voltage connector need, 100% hi-pot certification, and a commitment to zero-compromise safety, Coaxwave delivers the most suitable high-voltage cable for your exact medical, radar, ESD, and nuclear requirement.