Coaxwave 10kV High-Voltage Coaxial Cable | 50Ω DC-100MHz | 10kV DC/7kV AC | 35kV DC Hi-Pot | SHV MHV BNC.HT C-Type N-HV | Medical Radar Particle Accelerator
  • Coaxwave 10kV High-Voltage Coaxial Cable | 50Ω DC-100MHz | 10kV DC/7kV AC | 35kV DC Hi-Pot | SHV MHV BNC.HT C-Type N-HV | Medical Radar Particle Accelerator
  • 1/1
  • Coaxwave 10kV High-Voltage Coaxial Cable | 50Ω DC-100MHz | 10kV DC/7kV AC | 35kV DC Hi-Pot | SHV MHV BNC.HT C-Type N-HV | Medical Radar Particle Accelerator

Coaxwave 10kV High-Voltage Coaxial Cable | 50Ω DC-100MHz | 10kV DC/7kV AC | 35kV DC Hi-Pot | SHV MHV BNC.HT C-Type N-HV | Medical Radar Particle Accelerator

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 10kV High-Voltage Coaxial Cable Assembly is the core product of the high-voltage cable series, 50Ω characteristic impedance, DC–100MHz, rated 10kV DC / 7kV RMS AC. Silver-plated copper braid shield + XLPE or PTFE dielectric + oxygen-free copper center conductor. PUR or LSZH jacket per application. 100% hi-pot tested at 21.75kV AC/5min or 35kV DC/15min, insulation resistance ≥400MΩ, partial discharge ≤10pC @ 1.73U₀, shield verified. Covers 10kV dedicated, SHV, MHV, BNC.HT, C-type, N-type HV full matrix. All with recessed contact anti-shock design. Ideal for HV power supplies, medical electronics, radar transmitters, particle accelerators, and T&M.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Architecture — RF Performance Meets HV Safety

Attribute

10kV High-Voltage Specification

Rated Voltage

10kV DC / 7kV RMS AC

Frequency Range

DC – 100 MHz

Characteristic Impedance

50Ω ±2Ω

Dielectric Options

XLPE (cross-linked polyethylene, -40℃ to +90℃) or PTFE (Teflon®, -55℃ to +200℃)

Shield

Silver-plated copper braid, ≥90% coverage

Center Conductor

Oxygen-free copper (OFC), solid or stranded

Jacket Options

PUR (polyurethane, flexible, oil-resistant) or LSZH (low-smoke zero-halogen, flame-retardant)

Insulator (Connector)

PTFE, recessed contact cavity

Hi-Pot Test (Factory)

35kV DC / 15 min OR 21.75kV AC / 5 min, 100%

All Transfer Models (complete 10kV high-voltage connector matrix — type × gender × mounting):

No.

Model Name

Connector Type

Gender

Mounting

Voltage

Notes

1

CW-HV10-DED-M-STR

10kV Dedicated

Male

Straight free

10kV DC

Primary 10kV interconnect

2

CW-HV10-DED-F-STR

10kV Dedicated

Female

Straight free

10kV DC

DUT-side 10kV

3

CW-HV10-DED-M-RA

10kV Dedicated

Male

Right-angle

10kV DC

Space-constrained HV

4

CW-HV10-DED-F-BLK

10kV Dedicated

Female

Bulkhead

10kV DC

HV panel feedthrough

5

CW-HV10-DED-M-2HF

10kV Dedicated

Male

2-hole flange

10kV DC

Chassis mount

6

CW-HV10-SHV-M-STR

SHV

Male

Straight free

10kV DC

Industry-standard HV

7

CW-HV10-SHV-F-STR

SHV

Female

Straight free

10kV DC

SHV DUT side

8

CW-HV10-SHV-F-BLK

SHV

Female

Bulkhead

10kV DC

SHV panel mount

9

CW-HV10-MHV-M-STR

MHV

Male

Straight free

5kV DC*

Legacy HV (5kV max)

10

CW-HV10-BNC-HT-M-STR

BNC.HT

Male

Straight free

5kV DC*

High-voltage BNC

11

CW-HV10-BNC-HT-F-BLK

BNC.HT

Female

Bulkhead

5kV DC*

BNC.HT panel

12

CW-HV10-C-M-STR

C-Type

Male

Straight free

10kV DC

High-current pulse

13

CW-HV10-C-F-STR

C-Type

Female

Straight free

10kV DC

C-Type DUT

14

CW-HV10-N-HV-M-STR

N-Type HV

Male

Straight free

7kV RMS*

HV-modified N-Type

15

CW-HV10-N-HV-F-BLK

N-Type HV

Female

Bulkhead

7kV RMS*

N-HV panel feed

* MHV and BNC.HT rated to 5kV DC per IEC 61169-38. N-Type HV rated to 7kV RMS AC. 10kV Dedicated, SHV, and C-Type rated to 10kV DC.

💡 All 15 configurations share the same 10kV cable platform. Dielectric: XLPE (economical, 90℃) or PTFE (high-temp, 200℃). Jacket: PUR (flexible) or LSZH (flame-retardant, indoor). Every assembly is 100% hi-pot tested before shipment.

Key Performance (Coaxwave 10kV specification):

  • Rated Voltage: 10kV DC / 7kV RMS AC (continuous, sea level, 25℃)

  • Frequency Response: DC – 100 MHz (cable limited; connectors vary)

  • Test Voltage: 35kV DC / 15 min OR 21.75kV AC / 5 min, 100% per assembly

  • Insulation Resistance: ≥ 400 MΩ @ 20℃ (500V DC test)

  • Partial Discharge: ≤ 10 pC @ 1.73U₀ (17.3kV DC, XLPE/PTFE grade)

  • Impedance: 50Ω ±2Ω

  • Capacitance: ~95 pF/m (XLPE), ~90 pF/m (PTFE)

Inspection: 100% hi-pot (35kV DC/15min or 21.75kV AC/5min) + insulation resistance (≥400MΩ) + partial discharge (≤10pC @ 1.73U₀) + shield continuity. Each assembly ships with an individual test certificate — hi-pot record, IR value, PD level, and SN traceability.

🎯 Core Positioning: When You Need RF Bandwidth AND 10kV Isolation

Standard 50Ω RF cables (RG58, RG223) are not rated for high-voltage DC or AC stress beyond a few hundred volts. Conversely, standard HV wires (silicone-insulated) have no defined characteristic impedance and cannot support even 1MHz signal transmission. Coaxwave 10kV assemblies occupy the intersection: a controlled 50Ω environment that safely carries up to 10kV. This makes them uniquely suited for pulsed power systems, medical X-ray generators, and particle accelerator beamline instrumentation where both voltage rating and signal integrity matter.

⚡ Complete Connector Matrix

10kV Dedicated Series (Coaxwave Proprietary):

  • Male/Female Straight (CW-HV10-DED-M/F-STR): The primary 10kV interconnect. Recessed PTFE insulator, silver-plated copper contact. For medical imaging, capacitor charging, and ESD systems.

  • Male Right-Angle (CW-HV10-DED-M-RA): 90° exit for compact equipment racks where straight-cable clearance is insufficient.

  • Female Bulkhead (CW-HV10-DED-F-BLK): Panel feedthrough for HV entry into shielded enclosures or HV power supplies.

  • Male 2-Hole Flange (CW-HV10-DED-M-2HF): Chassis-mounted HV port for permanent equipment installation with secure mechanical retention.

SHV Series (10kV Industry Standard):

  • SHV Male/Female (CW-HV10-SHV-M/F-STR): IEC 61169-38 compliant 10kV connector. Recessed contact, safe mating. Compatible with all SHV-equipped test equipment and HV power supplies.

  • SHV Female Bulkhead (CW-HV10-SHV-F-BLK): Panel-mount SHV for instrumentation front panels.

MHV & BNC.HT Series (5kV Legacy):

  • MHV Male (CW-HV10-MHV-M-STR): 5kV DC legacy connector for older HV test sets. Not for 10kV use — clearly marked.

  • BNC.HT Male/Female Bulkhead (CW-HV10-BNC-HT-)*: High-voltage variant of BNC, rated 5kV DC. Bayonet coupling for quick-connect legacy systems.

C-Type Series (10kV High-Current Pulse):

  • C-Type Male/Female (CW-HV10-C-M/F-STR): High-current 10kV connector with enlarged center contact. For capacitor bank discharge, pulse forming networks, and modulator applications requiring both 10kV and high peak current.

N-Type HV Series (7kV RMS RF):

  • N-Type HV Male/Female Bulkhead (CW-HV10-N-HV-)*: High-voltage-modified N-Type connector, rated 7kV RMS AC. For RF systems operating at high voltage (e.g., broadcast transmitters, plasma generators).

🛡️ Coaxwave Quality Barrier

Every 10kV High-Voltage Coaxial Cable Assembly undergoes four mandatory 100% controls:

  1. Hi-Pot Proof Test: 35kV DC for 15 minutes OR 21.75kV AC for 5 minutes (customer-specified). No breakdown, no flashover, leakage < 1 μA. This is 3.5× the DC rating — a conservative safety margin.

  2. Insulation Resistance Test: ≥ 400 MΩ measured at 500V DC @ 20℃. Confirms dielectric uniformity over the full cable length.

  3. Partial Discharge Test: ≤ 10 pC extinction voltage at 1.73U₀ (17.3kV DC). Ensures no internal micro-voids that could cause long-term dielectric degradation.

  4. Shield Continuity & Coverage: Silver-plated copper braid verified for ≥90% coverage and low DC resistance to ground.

Each assembly ships with an individual test certificate — hi-pot pass record, insulation resistance value, partial discharge data, and laser-marked serial number for full traceability.


Electrical Performance

  • Rated Voltage: 10kV DC / 7kV RMS AC (continuous, sea level, 25℃)

  • Frequency Range: DC – 100 MHz (cable limited; connector dependent)

  • Test Voltage: 35kV DC / 15 min OR 21.75kV AC / 5 min (100% factory)

  • Insulation Resistance: ≥ 400 MΩ @ 20℃ (500V DC)

  • Partial Discharge: ≤ 10 pC @ 1.73U₀ (17.3kV DC)

  • Impedance: 50Ω ±2Ω

  • Capacitance: ~95 pF/m (XLPE), ~90 pF/m (PTFE)

  • Velocity Factor: ~66% (XLPE), ~70% (PTFE)

Mechanical Performance

  • Cable Outer Diameter: ~7.5 mm (typical, dielectric and jacket dependent)

  • Minimum Bend Radius: 10× OD (static), 15× OD (dynamic)

  • Connector Coupling: Threaded (10kV Dedicated: M10×1.0; SHV: 1/4-28 UNS modified; MHV: 3/8-32 UNEF; C-Type: M12×1.0; N-HV: 1/4-28 UNS)

  • Torque: 10kV Dedicated: 1.2 N·m; SHV: 0.8 N·m; MHV: 0.6 N·m; C-Type: 1.5 N·m; N-HV: 1.1 N·m

  • Mating Cycles: ≥ 500 (all types)

  • Contact Retention: Center contact recessed ≥ 3 mm inside insulator (unmated)

Materials & Structure

  • Center Conductor: Oxygen-free copper (OFC), silver-plated, solid or 7×0.4mm stranded

  • Dielectric: XLPE (cross-linked polyethylene) or PTFE (Teflon®)

  • Shield: Silver-plated copper braid, ≥90% coverage

  • Outer Jacket: PUR (polyurethane, black, flexible) or LSZH (low-smoke zero-halogen, orange, flame-retardant)

  • Connector Insulator: PTFE, recessed cavity design

  • Connector Body: Brass, nickel-plated or passivated stainless steel

Environment & Compliance

  • Operating Temperature: -55℃ ~ +200℃ (PTFE dielectric + PUR jacket); -40℃ ~ +90℃ (XLPE + LSZH)

  • Storage Temperature: -65℃ ~ +85℃

  • Flame Rating: LSZH per IEC 60332-1; UL 94 V-0 (PUR)

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • ⚠️ CRITICAL SAFETY: Never Mate or De-mate Under Voltage:

    • High-voltage connectors MUST be de-energized and safely discharged before handling

    • Always verify zero voltage with a certified HV probe before any connection change


  • Connector Torque:

    • Use the specified torque wrench for each connector type

    • Do NOT over-tighten — excessive torque can crack the PTFE insulator, exposing HV contact

    • Do NOT under-tighten — loose coupling increases contact resistance → localized heating → flashover risk


  • Bend Radius:

    • Respect minimum 10× OD (static), 15× OD (dynamic)

    • Never kink — sharp bends thin the dielectric wall locally → HV breakdown


  • Routing:

    • Maintain ≥ 50 mm clearance from low-voltage signal cables

    • Use ceramic or non-conductive clamps — never metal cable ties

    • Route away from sharp edges



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

Medical X-Ray / CT

CW-HV10-DED-F-BLK

10kV bulkhead, recessed

X-ray tube HV bias feed

Radar Modulator

CW-HV10-C-M-STR

C-Type high-current, 10kV

Pulse modulator output

Particle Accelerator

CW-HV10-BNC-HT-M-STR

BNC.HT, quick-connect

Beamline HV bias

HV Power Supply

CW-HV10-SHV-F-BLK

SHV panel mount

Lab HV distribution

Plasma Generator

CW-HV10-N-HV-M-STR

N-HV, 7kV RMS RF

RF plasma excitation

Capacitor Bank

CW-HV10-C-F-STR

C-Type, high peak current

Pulse discharge

Industrial ESD

CW-HV10-DED-M-RA

10kV RA, compact

ESD simulator output

Nuclear Detector

CW-HV10-DED-M-STR

10kV dedicated

PMT/APD HV bias

Broadcast TX

CW-HV10-N-HV-F-BLK

N-HV bulkhead

Transmitter HV feed

University Lab

CW-HV10-SHV-M-STR

SHV standard, safe

Educational HV experiments

Standard Matrix & Extensions

  • Connector Types: 10kV Dedicated, SHV, MHV, BNC.HT, C-Type, N-Type HV — all genders and mountings

  • Dielectric Options: XLPE (economy, 90℃) or PTFE (high-temp, 200℃)

  • Jacket Options: PUR (flexible, oil-resistant) or LSZH (flame-retardant, indoor/safety-critical)

  • Lengths: 0.3 m to 25 m (standard); custom lengths available

  • Full Kit: Cable assembly + test certificate + torque wrench + HV safety caps

⚡ Electrical Performance Customization

  • Extended Hi-Pot: 40kV DC / 15 min available for additional safety margin

  • Partial Discharge Optimization: Custom XLPE formulation for < 5 pC @ 1.73U₀

  • Triaxial Version: Inner HV coax + outer guard shield for ultra-low-leakage measurements

Structural Customization

  • Right-Angle at Either End: 90° 10kV Dedicated or SHV for space-constrained routing

  • Bulkhead with HV Interlock: Microswitch that cuts power when bulkhead is opened

  • Overmolded Strain Relief: HV-rated TPE boots at connector-cable junction

️ Material & Environmental Customization

  • Oil-Resistant PUR: Special compound for transformer and oil-filled environments

  • High-Temp PTFE/FEP: For +200℃ continuous operation (e.g., downhole tools)

  • Non-Magnetic Version: For EMC chambers and precision HV metrology

Service & Support

  • 100% 35kV Hi-Pot Test: Every assembly tested before shipment

  • Individual Test Certificate: Hi-pot pass, IR value, PD data, SN traceability

  • SN Traceability: Laser-marked unique serial numbers on every connector

  • Rapid Prototyping: Standard configurations 2–3 weeks; custom 4–6 weeks

  • Application Engineering: Coaxwave engineers provide:

    • Voltage derating guidance for altitude and temperature

    • Connector selection (SHV vs. C-Type vs. 10kV Dedicated)

    • HV safety clearance and routing recommendations

    • Partial discharge strategy for medical/nuclear compliance


Tip

"There is no perfect standard part, only the most suitable solution."

Standard Matrix & Extensions

  • Connector Types: 10kV Dedicated, SHV, MHV, BNC.HT, C-Type, N-Type HV — all genders and mountings

  • Dielectric Options: XLPE (economy, 90℃) or PTFE (high-temp, 200℃)

  • Jacket Options: PUR (flexible, oil-resistant) or LSZH (flame-retardant, indoor/safety-critical)

  • Lengths: 0.3 m to 25 m (standard); custom lengths available

  • Full Kit: Cable assembly + test certificate + torque wrench + HV safety caps

⚡ Electrical Performance Customization

  • Extended Hi-Pot: 40kV DC / 15 min available for additional safety margin

  • Partial Discharge Optimization: Custom XLPE formulation for < 5 pC @ 1.73U₀

  • Triaxial Version: Inner HV coax + outer guard shield for ultra-low-leakage measurements

Structural Customization

  • Right-Angle at Either End: 90° 10kV Dedicated or SHV for space-constrained routing

  • Bulkhead with HV Interlock: Microswitch that cuts power when bulkhead is opened

  • Overmolded Strain Relief: HV-rated TPE boots at connector-cable junction

️ Material & Environmental Customization

  • Oil-Resistant PUR: Special compound for transformer and oil-filled environments

  • High-Temp PTFE/FEP: For +200℃ continuous operation (e.g., downhole tools)

  • Non-Magnetic Version: For EMC chambers and precision HV metrology

Service & Support

  • 100% 35kV Hi-Pot Test: Every assembly tested before shipment

  • Individual Test Certificate: Hi-pot pass, IR value, PD data, SN traceability

  • SN Traceability: Laser-marked unique serial numbers on every connector

  • Rapid Prototyping: Standard configurations 2–3 weeks; custom 4–6 weeks

  • Application Engineering: Coaxwave engineers provide:

    • Voltage derating guidance for altitude and temperature

    • Connector selection (SHV vs. C-Type vs. 10kV Dedicated)

    • HV safety clearance and routing recommendations

    • Partial discharge strategy for medical/nuclear compliance


Tip

"There is no perfect standard part, only the most suitable solution."