Architecture — RF Performance Meets HV Safety
Attribute | 10kV High-Voltage Specification |
|---|---|
Rated Voltage | 10kV DC / 7kV RMS AC |
Frequency Range | DC – 100 MHz |
Characteristic Impedance | 50Ω ±2Ω |
Dielectric Options | XLPE (cross-linked polyethylene, -40℃ to +90℃) or PTFE (Teflon®, -55℃ to +200℃) |
Shield | Silver-plated copper braid, ≥90% coverage |
Center Conductor | Oxygen-free copper (OFC), solid or stranded |
Jacket Options | PUR (polyurethane, flexible, oil-resistant) or LSZH (low-smoke zero-halogen, flame-retardant) |
Insulator (Connector) | PTFE, recessed contact cavity |
Hi-Pot Test (Factory) | 35kV DC / 15 min OR 21.75kV AC / 5 min, 100% |
All Transfer Models (complete 10kV high-voltage connector matrix — type × gender × mounting):
No. | Model Name | Connector Type | Gender | Mounting | Voltage | Notes |
|---|---|---|---|---|---|---|
1 | CW-HV10-DED-M-STR | 10kV Dedicated | Male | Straight free | 10kV DC | Primary 10kV interconnect |
2 | CW-HV10-DED-F-STR | 10kV Dedicated | Female | Straight free | 10kV DC | DUT-side 10kV |
3 | CW-HV10-DED-M-RA | 10kV Dedicated | Male | Right-angle | 10kV DC | Space-constrained HV |
4 | CW-HV10-DED-F-BLK | 10kV Dedicated | Female | Bulkhead | 10kV DC | HV panel feedthrough |
5 | CW-HV10-DED-M-2HF | 10kV Dedicated | Male | 2-hole flange | 10kV DC | Chassis mount |
6 | CW-HV10-SHV-M-STR | SHV | Male | Straight free | 10kV DC | Industry-standard HV |
7 | CW-HV10-SHV-F-STR | SHV | Female | Straight free | 10kV DC | SHV DUT side |
8 | CW-HV10-SHV-F-BLK | SHV | Female | Bulkhead | 10kV DC | SHV panel mount |
9 | CW-HV10-MHV-M-STR | MHV | Male | Straight free | 5kV DC* | Legacy HV (5kV max) |
10 | CW-HV10-BNC-HT-M-STR | BNC.HT | Male | Straight free | 5kV DC* | High-voltage BNC |
11 | CW-HV10-BNC-HT-F-BLK | BNC.HT | Female | Bulkhead | 5kV DC* | BNC.HT panel |
12 | CW-HV10-C-M-STR | C-Type | Male | Straight free | 10kV DC | High-current pulse |
13 | CW-HV10-C-F-STR | C-Type | Female | Straight free | 10kV DC | C-Type DUT |
14 | CW-HV10-N-HV-M-STR | N-Type HV | Male | Straight free | 7kV RMS* | HV-modified N-Type |
15 | CW-HV10-N-HV-F-BLK | N-Type HV | Female | Bulkhead | 7kV RMS* | N-HV panel feed |
* MHV and BNC.HT rated to 5kV DC per IEC 61169-38. N-Type HV rated to 7kV RMS AC. 10kV Dedicated, SHV, and C-Type rated to 10kV DC.
💡 All 15 configurations share the same 10kV cable platform. Dielectric: XLPE (economical, 90℃) or PTFE (high-temp, 200℃). Jacket: PUR (flexible) or LSZH (flame-retardant, indoor). Every assembly is 100% hi-pot tested before shipment.
Key Performance (Coaxwave 10kV specification):
Rated Voltage: 10kV DC / 7kV RMS AC (continuous, sea level, 25℃)
Frequency Response: DC – 100 MHz (cable limited; connectors vary)
Test Voltage: 35kV DC / 15 min OR 21.75kV AC / 5 min, 100% per assembly
Insulation Resistance: ≥ 400 MΩ @ 20℃ (500V DC test)
Partial Discharge: ≤ 10 pC @ 1.73U₀ (17.3kV DC, XLPE/PTFE grade)
Impedance: 50Ω ±2Ω
Capacitance: ~95 pF/m (XLPE), ~90 pF/m (PTFE)
Inspection: 100% hi-pot (35kV DC/15min or 21.75kV AC/5min) + insulation resistance (≥400MΩ) + partial discharge (≤10pC @ 1.73U₀) + shield continuity. Each assembly ships with an individual test certificate — hi-pot record, IR value, PD level, and SN traceability.
Standard 50Ω RF cables (RG58, RG223) are not rated for high-voltage DC or AC stress beyond a few hundred volts. Conversely, standard HV wires (silicone-insulated) have no defined characteristic impedance and cannot support even 1MHz signal transmission. Coaxwave 10kV assemblies occupy the intersection: a controlled 50Ω environment that safely carries up to 10kV. This makes them uniquely suited for pulsed power systems, medical X-ray generators, and particle accelerator beamline instrumentation where both voltage rating and signal integrity matter.
10kV Dedicated Series (Coaxwave Proprietary):
Male/Female Straight (CW-HV10-DED-M/F-STR): The primary 10kV interconnect. Recessed PTFE insulator, silver-plated copper contact. For medical imaging, capacitor charging, and ESD systems.
Male Right-Angle (CW-HV10-DED-M-RA): 90° exit for compact equipment racks where straight-cable clearance is insufficient.
Female Bulkhead (CW-HV10-DED-F-BLK): Panel feedthrough for HV entry into shielded enclosures or HV power supplies.
Male 2-Hole Flange (CW-HV10-DED-M-2HF): Chassis-mounted HV port for permanent equipment installation with secure mechanical retention.
SHV Series (10kV Industry Standard):
SHV Male/Female (CW-HV10-SHV-M/F-STR): IEC 61169-38 compliant 10kV connector. Recessed contact, safe mating. Compatible with all SHV-equipped test equipment and HV power supplies.
SHV Female Bulkhead (CW-HV10-SHV-F-BLK): Panel-mount SHV for instrumentation front panels.
MHV & BNC.HT Series (5kV Legacy):
MHV Male (CW-HV10-MHV-M-STR): 5kV DC legacy connector for older HV test sets. Not for 10kV use — clearly marked.
BNC.HT Male/Female Bulkhead (CW-HV10-BNC-HT-)*: High-voltage variant of BNC, rated 5kV DC. Bayonet coupling for quick-connect legacy systems.
C-Type Series (10kV High-Current Pulse):
C-Type Male/Female (CW-HV10-C-M/F-STR): High-current 10kV connector with enlarged center contact. For capacitor bank discharge, pulse forming networks, and modulator applications requiring both 10kV and high peak current.
N-Type HV Series (7kV RMS RF):
N-Type HV Male/Female Bulkhead (CW-HV10-N-HV-)*: High-voltage-modified N-Type connector, rated 7kV RMS AC. For RF systems operating at high voltage (e.g., broadcast transmitters, plasma generators).
Every 10kV High-Voltage Coaxial Cable Assembly undergoes four mandatory 100% controls:
Hi-Pot Proof Test: 35kV DC for 15 minutes OR 21.75kV AC for 5 minutes (customer-specified). No breakdown, no flashover, leakage < 1 μA. This is 3.5× the DC rating — a conservative safety margin.
Insulation Resistance Test: ≥ 400 MΩ measured at 500V DC @ 20℃. Confirms dielectric uniformity over the full cable length.
Partial Discharge Test: ≤ 10 pC extinction voltage at 1.73U₀ (17.3kV DC). Ensures no internal micro-voids that could cause long-term dielectric degradation.
Shield Continuity & Coverage: Silver-plated copper braid verified for ≥90% coverage and low DC resistance to ground.
Each assembly ships with an individual test certificate — hi-pot pass record, insulation resistance value, partial discharge data, and laser-marked serial number for full traceability.
Rated Voltage: 10kV DC / 7kV RMS AC (continuous, sea level, 25℃)
Frequency Range: DC – 100 MHz (cable limited; connector dependent)
Test Voltage: 35kV DC / 15 min OR 21.75kV AC / 5 min (100% factory)
Insulation Resistance: ≥ 400 MΩ @ 20℃ (500V DC)
Partial Discharge: ≤ 10 pC @ 1.73U₀ (17.3kV DC)
Impedance: 50Ω ±2Ω
Capacitance: ~95 pF/m (XLPE), ~90 pF/m (PTFE)
Velocity Factor: ~66% (XLPE), ~70% (PTFE)
Cable Outer Diameter: ~7.5 mm (typical, dielectric and jacket dependent)
Minimum Bend Radius: 10× OD (static), 15× OD (dynamic)
Connector Coupling: Threaded (10kV Dedicated: M10×1.0; SHV: 1/4-28 UNS modified; MHV: 3/8-32 UNEF; C-Type: M12×1.0; N-HV: 1/4-28 UNS)
Torque: 10kV Dedicated: 1.2 N·m; SHV: 0.8 N·m; MHV: 0.6 N·m; C-Type: 1.5 N·m; N-HV: 1.1 N·m
Mating Cycles: ≥ 500 (all types)
Contact Retention: Center contact recessed ≥ 3 mm inside insulator (unmated)
Center Conductor: Oxygen-free copper (OFC), silver-plated, solid or 7×0.4mm stranded
Dielectric: XLPE (cross-linked polyethylene) or PTFE (Teflon®)
Shield: Silver-plated copper braid, ≥90% coverage
Outer Jacket: PUR (polyurethane, black, flexible) or LSZH (low-smoke zero-halogen, orange, flame-retardant)
Connector Insulator: PTFE, recessed cavity design
Connector Body: Brass, nickel-plated or passivated stainless steel
Operating Temperature: -55℃ ~ +200℃ (PTFE dielectric + PUR jacket); -40℃ ~ +90℃ (XLPE + LSZH)
Storage Temperature: -65℃ ~ +85℃
Flame Rating: LSZH per IEC 60332-1; UL 94 V-0 (PUR)
RoHS / REACH: Compliant
Quality System: ISO 9001:2015 / AS9100D
⚠️ CRITICAL SAFETY: Never Mate or De-mate Under Voltage:
High-voltage connectors MUST be de-energized and safely discharged before handling
Always verify zero voltage with a certified HV probe before any connection change
Connector Torque:
Use the specified torque wrench for each connector type
Do NOT over-tighten — excessive torque can crack the PTFE insulator, exposing HV contact
Do NOT under-tighten — loose coupling increases contact resistance → localized heating → flashover risk
Bend Radius:
Respect minimum 10× OD (static), 15× OD (dynamic)
Never kink — sharp bends thin the dielectric wall locally → HV breakdown
Routing:
Maintain ≥ 50 mm clearance from low-voltage signal cables
Use ceramic or non-conductive clamps — never metal cable ties
Route away from sharp edges
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
Medical X-Ray / CT | CW-HV10-DED-F-BLK | 10kV bulkhead, recessed | X-ray tube HV bias feed |
Radar Modulator | CW-HV10-C-M-STR | C-Type high-current, 10kV | Pulse modulator output |
Particle Accelerator | CW-HV10-BNC-HT-M-STR | BNC.HT, quick-connect | Beamline HV bias |
HV Power Supply | CW-HV10-SHV-F-BLK | SHV panel mount | Lab HV distribution |
Plasma Generator | CW-HV10-N-HV-M-STR | N-HV, 7kV RMS RF | RF plasma excitation |
Capacitor Bank | CW-HV10-C-F-STR | C-Type, high peak current | Pulse discharge |
Industrial ESD | CW-HV10-DED-M-RA | 10kV RA, compact | ESD simulator output |
Nuclear Detector | CW-HV10-DED-M-STR | 10kV dedicated | PMT/APD HV bias |
Broadcast TX | CW-HV10-N-HV-F-BLK | N-HV bulkhead | Transmitter HV feed |
University Lab | CW-HV10-SHV-M-STR | SHV standard, safe | Educational HV experiments |
Connector Types: 10kV Dedicated, SHV, MHV, BNC.HT, C-Type, N-Type HV — all genders and mountings
Dielectric Options: XLPE (economy, 90℃) or PTFE (high-temp, 200℃)
Jacket Options: PUR (flexible, oil-resistant) or LSZH (flame-retardant, indoor/safety-critical)
Lengths: 0.3 m to 25 m (standard); custom lengths available
Full Kit: Cable assembly + test certificate + torque wrench + HV safety caps
Extended Hi-Pot: 40kV DC / 15 min available for additional safety margin
Partial Discharge Optimization: Custom XLPE formulation for < 5 pC @ 1.73U₀
Triaxial Version: Inner HV coax + outer guard shield for ultra-low-leakage measurements
Right-Angle at Either End: 90° 10kV Dedicated or SHV for space-constrained routing
Bulkhead with HV Interlock: Microswitch that cuts power when bulkhead is opened
Overmolded Strain Relief: HV-rated TPE boots at connector-cable junction
Oil-Resistant PUR: Special compound for transformer and oil-filled environments
High-Temp PTFE/FEP: For +200℃ continuous operation (e.g., downhole tools)
Non-Magnetic Version: For EMC chambers and precision HV metrology
100% 35kV Hi-Pot Test: Every assembly tested before shipment
Individual Test Certificate: Hi-pot pass, IR value, PD data, SN traceability
SN Traceability: Laser-marked unique serial numbers on every connector
Rapid Prototyping: Standard configurations 2–3 weeks; custom 4–6 weeks
Application Engineering: Coaxwave engineers provide:
Voltage derating guidance for altitude and temperature
Connector selection (SHV vs. C-Type vs. 10kV Dedicated)
HV safety clearance and routing recommendations
Partial discharge strategy for medical/nuclear compliance
Tip
"There is no perfect standard part, only the most suitable solution."
Connector Types: 10kV Dedicated, SHV, MHV, BNC.HT, C-Type, N-Type HV — all genders and mountings
Dielectric Options: XLPE (economy, 90℃) or PTFE (high-temp, 200℃)
Jacket Options: PUR (flexible, oil-resistant) or LSZH (flame-retardant, indoor/safety-critical)
Lengths: 0.3 m to 25 m (standard); custom lengths available
Full Kit: Cable assembly + test certificate + torque wrench + HV safety caps
Extended Hi-Pot: 40kV DC / 15 min available for additional safety margin
Partial Discharge Optimization: Custom XLPE formulation for < 5 pC @ 1.73U₀
Triaxial Version: Inner HV coax + outer guard shield for ultra-low-leakage measurements
Right-Angle at Either End: 90° 10kV Dedicated or SHV for space-constrained routing
Bulkhead with HV Interlock: Microswitch that cuts power when bulkhead is opened
Overmolded Strain Relief: HV-rated TPE boots at connector-cable junction
Oil-Resistant PUR: Special compound for transformer and oil-filled environments
High-Temp PTFE/FEP: For +200℃ continuous operation (e.g., downhole tools)
Non-Magnetic Version: For EMC chambers and precision HV metrology
100% 35kV Hi-Pot Test: Every assembly tested before shipment
Individual Test Certificate: Hi-pot pass, IR value, PD data, SN traceability
SN Traceability: Laser-marked unique serial numbers on every connector
Rapid Prototyping: Standard configurations 2–3 weeks; custom 4–6 weeks
Application Engineering: Coaxwave engineers provide:
Voltage derating guidance for altitude and temperature
Connector selection (SHV vs. C-Type vs. 10kV Dedicated)
HV safety clearance and routing recommendations
Partial discharge strategy for medical/nuclear compliance
Tip