1.85mm (V-Type) Connectors: 65 GHz Interconnects for Next-Generation RF Systems

2026-08-22 19:52 coaxwave
2

The 1.85mm (V-type) connector is the interface of choice for applications exceeding 40 GHz. With a 65 GHz upper frequency, it covers 5G FR2, 77 GHz automotive radar, and satellite Ka-band. This article outlines the technical rationale and sourcing considerations for 1.85mm deployments—written from a manufacturing engineer's perspective, not a marketing department's.


1. Technical Positioning

RF coaxial interfaces follow a clear frequency ladder. The 1.85mm sits at the 65 GHz tier—above general-purpose 2.92mm (40 GHz) but below metrology-grade 1.0mm (110 GHz).

Interface

Upper Freq

Primary Application

SMA

18 GHz

Legacy systems, general test

2.92mm (K)

40 GHz

5G mmWave, SatCom, lab VNA

1.85mm (V)

65 GHz

77 GHz radar, 6G R&D, A&D

1.0mm

110 GHz

Fundamental research, THz

Key electrical and mechanical parameters:

  • Frequency range: DC to 65 GHz

  • VSWR: ≤ 1.25 (DC–50 GHz) / ≤ 1.35 (50–65 GHz)

  • Insertion loss: ≤ 0.5 dB @ 65 GHz (1 m assembly)

  • Impedance: 50 Ω

  • Center pin diameter: 0.185 mm — requires machining tolerance within ±2.5 μm

  • Interface standard: MIL-STD-348B, IEEE 287

  • Mechanical life: ≥ 500 mating cycles

The 0.185 mm center conductor is the defining constraint. It is significantly more delicate than the 0.3 mm pin of a 2.92mm. This is not a defect—it is the physical price of reaching 65 GHz in a threaded coaxial format.


2. Where the Demand Comes From

77 GHz Automotive Radar (76–81 GHz)

Production radar modules require 65 GHz-capable interconnects for bench validation. 1.85mm test cables are the standard interface before systems transition to waveguide for over-the-air characterization.

5G FR2 and 6G Pre-Research

FR2 bands (24–52 GHz) sit entirely within the 1.85mm window. Early 6G sub-THz research (D-band, 110–170 GHz) uses 1.85mm for front-end signal path validation before stepping up to 1.0mm.

Low-Earth Orbit Satellites

Ka-band transceivers (27.5–31 GHz uplink / 17.7–21.2 GHz downlink) operate well within 65 GHz. Ground terminal integration and payload test fixtures rely on 1.85mm interconnects for signal integrity.

Aerospace & Defense

Electronic warfare, SIGINT, and satcom terminals operating above 40 GHz specify 1.85mm interfaces where size and weight constraints rule out larger connectors.


3. What Engineering Teams Should Verify

When sourcing 1.85mm components, performance claims mean nothing without documented evidence. Verify the following:

  • Dimensional inspection: Center conductor concentricity within 3 μm. Request measurement data, not just a pass/fail statement.

  • Phase stability under flexure: Documented phase deviation over a 90° bend at 18 GHz. Claiming "phase stable" without a number is not engineering.

  • Test data per shipment: Every cable should include a 2-port S-parameter sweep. If your supplier's VNA only reaches 26.5 GHz or 40 GHz, the data must state the actual measured range—not extrapolate.

  • Cable construction: Strain relief design and armor options should match the use environment (lab bench vs. production floor).


4. The Coaxwave Approach

We do not describe 1.85mm cables as "equivalent to" any brand or specification. We define performance against measurable electrical budgets:

  • Insertion loss: ≤ 0.5 dB @ 65 GHz for 1 m assemblies (measured or simulated with traceable correlation)

  • Phase stability: ≤ ±5° @ 18 GHz over 90° bend (per MIL-STD-202, Method 211)

  • Every shipment includes: Full S-parameter data, serialized cable ID, and dimensional inspection record

For laboratories in France, Belgium, Switzerland, and across Europe, the priority is not brand familiarity. It is documented, repeatable performance at 65 GHz with lead times that do not stall a project.


5. Conclusion

1.85mm (V-type) connectors will remain the volume interconnect for 65 GHz applications through this decade. The convergence of 77 GHz radar production, 5G FR2 expansion, and LEO satellite deployment ensures sustained demand. Selection criteria are straightforward: dimensional precision, verified phase stability, and transparent test documentation.