Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G DefenseCoaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G DefenseCoaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense
  • Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense
  • Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense
  • Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense
  • 1/3
  • Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense
  • Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense
  • Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense

Coaxwave WR90 to SMA Waveguide-to-Coax Adapter | 50Ω 8.2-12.4GHz X-Band | UBR100/FBP100 Flange | VSWR ≤1.25 | SMA M/F Straight Right-Angle | Radar SatCom 5G Defense

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave WR90 to SMA Waveguide-to-Coax Adapter bridges waveguide and SMA architectures in the X-band (8.2–12.4GHz), 50Ω characteristic impedance. WR90 rectangular waveguide with UBR100/FBP100 flange on the waveguide side; SMA coaxial interface with 1/4-28 UNS threaded coupling on the coax side. 100% VNA full-band S-parameter tested, CMM waveguide dimensional inspection, flange flatness verified. Factory VSWR ≤1.25:1, insertion loss ≤0.25dB. Available in SMA M/F × straight/right-angle full model matrix. The definitive X-band waveguide-coax transition for radar, SatCom, 5G backhaul, and defense systems.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Architecture Bridge — Waveguide to SMA

The WR90 rectangular waveguide (0.900" × 0.400" inner dimensions) is the dominant X-band transmission medium in radar and SatCom. The SMA coaxial interface is the global standard for test equipment and modular RF systems. Coaxwave's transition design uses a precision stepped-impedance probe inside the waveguide to couple energy from the TE₁₀ mode to the TEM coaxial mode. The probe position and depth are optimized via HFSS simulation to achieve <0.25dB insertion loss and VSWR ≤1.25 across the full 8.2–12.4GHz band.

Frequency Coverage:

Parameter

Specification

Frequency Range

8.2 – 12.4 GHz (X-band)

Waveguide

WR90 (MIL-DTL-3922)

Coax Interface

SMA (MIL-STD-348)

Impedance

50Ω ±0.5%

Flange Type

UBR100 / FBP100 (Cover or Chassis)

All Transfer Models (complete WR90-to-SMA adapter matrix — full SMA M/F × straight/right-angle):

No.

Model Name

SMA Gender

Body Style

Freq

Notes

1

CW-WR90-SMA-M-STR

SMA Male

Straight

8.2-12.4GHz

In-line, UBR100 flange

2

CW-WR90-SMA-F-STR

SMA Female

Straight

8.2-12.4GHz

In-line, UBR100 flange

3

CW-WR90-SMA-M-RA

SMA Male

90° Right-Angle

8.2-12.4GHz

Space-save, UBR100 flange

4

CW-WR90-SMA-F-RA

SMA Female

90° Right-Angle

8.2-12.4GHz

Space-save, UBR100 flange

💡 All four models share the same WR90 waveguide port and UBR100/FBP100 flange. The difference is SMA gender (Male/Female) and body orientation (Straight/Right-Angle). Right-angle versions use a precision 90° bend in the coax transition to minimize footprint in confined test bays.

Key Performance (independent Coaxwave test system):

  • VSWR: ≤ 1.25:1 (8.2–12.4GHz, full band)

  • Insertion Loss: ≤ 0.25 dB (including waveguide-to-probe transition)

  • Isolation: ≥ 80 dB (waveguide port to coax outer conductor)

Inspection: 100% VNA full-band S11/S21 sweep + CMM waveguide inner-dimension verification + flange flatness check (≤0.05mm). Each unit ships with an individual test report — your adapter's actual S-parameters. Laser-marked serial numbers guarantee full traceability.

🎯 Core Positioning: The X-Band Waveguide-Coax Bridge

WR90 is the workhorse waveguide for X-band. SMA is the workhorse coaxial interface for test and modular RF. Coaxwave WR90-to-SMA adapters are engineered to connect these two worlds with minimal loss and maximum repeatability. Every adapter is machined, assembled, and tested as a single integrated transition — not a waveguide flange bolted to a coax launcher.

⚡ Complete Adapter Matrix

SMA Male Straight (CW-WR90-SMA-M-STR):

  • SMA plug on coax side, in-line body. Best for direct connection to VNA test cables or panel-mounted SMA jacks.

SMA Female Straight (CW-WR90-SMA-F-STR):

  • SMA jack on coax side, in-line body. Best for connecting to SMA plug-terminated devices or bulkhead feedthroughs.

SMA Male Right-Angle (CW-WR90-SMA-M-RA):

  • SMA plug with 90° coax exit. Essential when the DUT or test cable approaches from the side — common in compact ATE fixtures.

SMA Female Right-Angle (CW-WR90-SMA-F-RA):

  • SMA jack with 90° coax exit. Ideal for side-entry test setups where the DUT presents an SMA male connector.

🛡️ Coaxwave Quality Barrier

Every WR90-to-SMA adapter undergoes three mandatory 100% tests:

  1. VNA Full-Band S-Parameter Sweep: S11 and S21 measured from 8.2GHz to 12.4GHz. VSWR ≤1.25 and IL ≤0.25dB verified per unit.

  2. CMM Waveguide Dimensional Verification: Inner dimensions (0.900" × 0.400") checked against MIL-DTL-3922. Flange hole pattern and flatness verified.

  3. Flange Flatness Check: UBR100/FBP100 flange surface inspected for flatness ≤0.05mm. Critical for maintaining RF seal when mated to waveguide components.

No sampling. Each unit ships with an individual test report — your adapter's actual measured S-parameters. Laser-marked serial numbers on every adapter guarantee full traceability.


Electrical Performance

  • Frequency Range: 8.2 – 12.4 GHz (X-band)

  • Impedance: 50Ω ±0.5%

  • VSWR: ≤ 1.25:1 (full band)

  • Insertion Loss: ≤ 0.25 dB (including transition)

  • Isolation: ≥ 80 dB (waveguide port to coax outer conductor)

Mechanical Performance

  • Waveguide Interface: WR90 per MIL-DTL-3922

  • Flange Type: UBR100 / FBP100 (Cover or Chassis, configurable)

  • Flange Flatness: ≤ 0.05 mm

  • Coax Coupling: SMA, 1/4-28 UNS thread

  • Coax Torque: 0.9 N·m (8 in-lbs) — use SMA torque wrench

  • Mounting Hardware: 4× screws (4-40 or 6-32), torque 0.9–1.1 N·m cross-pattern

Materials & Structure

  • Waveguide Body: Brass (CuZn), nickel-plated or passivated

  • Coax Outer Conductor: Passivated stainless steel (SUS303)

  • Center Contact: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PTFE (Teflon®)

  • Flange: Aluminum or brass, same plating as body

  • Interface Standard: MIL-DTL-3922 (waveguide), MIL-STD-348 (SMA)

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • Waveguide Side:

    • Align WR90 port with mating waveguide flange

    • Use UBR100/FBP100 cover flange with 4 screws

    • Tighten in cross-pattern (like lug nuts) to 0.9–1.1 N·m

    • Always use conductive gaskets between flanges for RF seal


  • Coax Side (SMA):

    • Screw SMA nut onto mating SMA connector

    • Torque to 0.9 N·m (8 in-lbs) with SMA torque wrench

    • Do NOT over-tighten — deforms dielectric → VSWR degrades above 12GHz


  • Right-Angle Orientation:

    • The 90° bend exits perpendicular to the waveguide broad wall

    • Plan cable routing accordingly to avoid stress on the SMA joint



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

X-band Radar Module Test

CW-WR90-SMA-M-STR

Straight, SMA male

VNA test cable direct connect

SatCom X-band Transceiver

CW-WR90-SMA-F-STR

Straight, SMA female

Bulkhead feedthrough

Compact ATE Fixture

CW-WR90-SMA-M-RA

Right-angle, SMA male

Side-entry in confined bay

5G Backhaul Radio Test

CW-WR90-SMA-F-RA

Right-angle, SMA female

Side-entry to SMA plug DUT

Aerospace Avionics Bay

CW-WR90-SMA-M-STR

Straight, rugged

Flight-line radar test

Defense EW Receiver

CW-WR90-SMA-F-STR

Straight, low loss

Signal intelligence system

Production HPA Test

CW-WR90-SMA-M-RA

Right-angle, space-save

High-power amplifier ATE

National Metrology Lab

CW-WR90-SMA-M-STR

Straight, metrology grade

Primary X-band standard

University Research Lab

CW-WR90-SMA-F-RA

Right-angle, flexible

Educational X-band experiments

Field Service Kit

CW-WR90-SMA-M-STR

Straight, rugged

Portable X-band test set

Standard Matrix & Extensions

  • 4 Standard Models: SMA M/F × Straight/Right-Angle

  • Flange Options: UBR100 cover, FBP100 chassis, CPR-90G, or custom patterns per customer drawing

  • Full Kit: Adapter + UBR100 cover flange + 4 screws + conductive gasket

⚡ Electrical Performance Customization

  • Low-IL Version: Insertion loss ≤ 0.20dB (extended probe optimization, for metrology use)

  • Extended Band: 8.0–12.5GHz (relaxed VSWR for broader coverage)

  • Phase-Matched Pairs: Two adapters matched to ±1° for differential X-band systems

Structural Customization

  • Alternate Flange: CPR-90G (gasketed), UG-135/U (choke), or custom bolt pattern

  • Panel-Mount Version: Fixed coax bulkhead with panel nut for permanent installation

  • Keyed SMA: Prevents mis-mating in multi-port arrays

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum X-band test

  • Hermetically Sealed: For pressurized waveguide systems

  • Extended Temperature: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every adapter measured 8.2-12.4GHz

  • Individual Test Report: Actual S-parameters (S11, S21) per unit

  • SN Traceability: Laser-marked unique serial numbers on every adapter

  • Rapid Prototyping: Standard models 2-3 week shipment; custom 4-6 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • Flange torque and gasket selection guidance

    • SMA torque best practices for X-band

    • Waveguide-to-coax calibration plane management

    • Multi-port array layout for phased X-band systems


Tip

"There is no perfect standard part, only the most suitable solution."


VNA Waveguide Calibration — X-Band

  • Setup: Mount CW-WR90-SMA-M-STR to VNA test port cable (SMA male). Connect waveguide side to WR90 calibration kit or DUT.

  • Workflow: Torque flange screws cross-pattern (0.9–1.1 N·m). Torque SMA to 0.9 N·m. Run VNA sweep 8.2–12.4GHz.

  • Why This Adapter: VSWR ≤1.25 ensures calibration residual error stays below 0.5dB. Right-angle version (CW-WR90-SMA-M-RA) used when test bay space is limited.

️ SatCom X-Band Transceiver Test

  • Setup: DUT has WR90 output flange. Use CW-WR90-SMA-F-STR to transition to SMA test equipment.

  • Workflow: Flange connection with conductive gasket. SMA female accepts DUT's SMA male cable. Quick connect/disconnect for production line.

  • Why This Adapter: 0.25dB max IL preserves signal integrity for low-noise X-band receiver test.

Production ATE — Right-Angle Advantage

  • Setup: ATE fixture has horizontal SMA test ports. Use CW-WR90-SMA-M-RA to connect to vertical WR90 DUT port.

  • Workflow: Right-angle body routes cable horizontally, avoiding vertical clearance issues. No cable stress.

  • Why This Adapter: Space-constrained fixtures benefit from 90° exit. No performance penalty vs. straight version.

⚠️ Usage Red Lines

  • ⚠️ Flange Torque Must Be Even (Cross-Pattern):

    • Always tighten 4 screws in cross-pattern (like lug nuts on a car)

    • Uneven torque causes flange warping → RF leakage → degraded VSWR

    • Torque: 0.9–1.1 N·m for all UBR100/FBP100 flanges


  • ⚠️ SMA Torque: 0.9 N·m (8 in-lbs) — Never Exceed:

    • Over-tightening deforms PTFE dielectric → impedance shift → VSWR degrades above 12GHz

    • Under-tightening causes intermittent contact → test repeatability failure

    • Always use a calibrated SMA torque wrench


  • ⚠️ Waveguide Orientation Matters:

    • WR90 has a broad wall (0.900") and narrow wall (0.400")

    • The adapter's probe is positioned relative to the broad wall

    • Never rotate the adapter 90° — this changes the polarization and kills the transition


  • Keep Waveguide Flanges Clean:

    • Dust or burrs on flange face cause RF leakage

    • Clean with IPA and lint-free wipe before every use

    • Cap waveguide opening when not in use



Coaxwave WR90 to SMA Waveguide-to-Coax Adapter · Delivery Commitment

  • Frequency: 8.2 – 12.4 GHz (X-band, WR90)

  • Impedance: 50Ω ±0.5%

  • VSWR: ≤ 1.25:1 (factory, per unit)

  • Insertion Loss: ≤ 0.25 dB (including transition)

  • Adapter Matrix: SMA M/F × Straight/Right-Angle = 4 standard models

  • Flange: UBR100 / FBP100 (configurable)

  • Materials: Brass waveguide body + stainless-steel coax + BeCu gold-plated center contact

  • 100% VNA Full-Band S-Parameter Test + CMM Waveguide Verification + Flange Flatness Check + Individual Test Report + SN Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for WR90-to-SMA Selection:

  1. Right-Angle Is Not a Compromise: The 90° version uses a precision bent transition — IL and VSWR match the straight version. Choose based on mechanical layout, not electrical fear.

  2. The Flange Gasket Is Part of the RF Path: Without a conductive gasket between WR90 flanges, RF leaks at the seam. Always install a gasket. Coaxwave supplies gaskets on request.

  3. SMA Torque at X-Band Is Critical: At 12.4GHz, a poorly torqued SMA connection adds 0.1–0.2dB of unpredictable loss. The 0.9 N·m specification is not a suggestion — it is the condition under which the adapter was characterized.


There is no perfect standard part, only the most suitable solution.

Coaxwave WR90 to SMA Waveguide-to-Coax Adapters are not merely mechanical transitions; they are the engineered bridge between two fundamentally different transmission architectures. We machine every brass body, optimize every probe depth, and verify every S-parameter with "German precision" and "French engineering logic". With four standard models covering every SMA gender and orientation need, 100% VNA certification, and a UBR100/FBP100 flange that mates to any WR90 system, Coaxwave delivers the most suitable waveguide-coax transition for your exact X-band, SatCom, 5G, and defense requirement.

Sales Email: sales@coaxial-rf.com