Architecture Bridge — Waveguide to SMA
The WR42 rectangular waveguide (0.420" × 0.170" inner dimensions) is the dominant K-band transmission medium. The SMA coaxial interface is the global standard for test equipment and modular RF systems. Coaxwave's transition design uses a precision stepped-impedance probe inside the waveguide to couple energy from the TE₁₀ mode to the TEM coaxial mode. The probe position and depth are optimized via HFSS simulation to achieve <0.3dB insertion loss and VSWR ≤1.25 across the full 18.0–26.5GHz band.
Frequency Coverage:
Parameter | Specification |
|---|---|
Frequency Range | 18.0 – 26.5 GHz (K-band) |
Waveguide | WR42 (MIL-DTL-3922) |
Coax Interface | SMA (MIL-STD-348) |
Impedance | 50Ω ±0.5% |
Flange Type | UBR220-series: Flat / Sealed / Choke (configurable) |
All Transfer Models (complete WR42-to-SMA adapter matrix — SMA M/F × straight/right-angle × 3 flange types = 12 standard models):
No. | Model Name | SMA Gender | Body Style | Flange Type | Freq | Notes |
|---|---|---|---|---|---|---|
1 | CW-WR42-SMA-M-STR-FLAT | SMA Male | Straight | UBR220 Flat | 18-26.5GHz | Standard panel mount |
2 | CW-WR42-SMA-F-STR-FLAT | SMA Female | Straight | UBR220 Flat | 18-26.5GHz | Standard panel mount |
3 | CW-WR42-SMA-M-RA-FLAT | SMA Male | 90° Right-Angle | UBR220 Flat | 18-26.5GHz | Space-save, side entry |
4 | CW-WR42-SMA-F-RA-FLAT | SMA Female | 90° Right-Angle | UBR220 Flat | 18-26.5GHz | Space-save, side entry |
5 | CW-WR42-SMA-M-STR-SEAL | SMA Male | Straight | UBR220 Sealed | 18-26.5GHz | Gasketed, pressurized systems |
6 | CW-WR42-SMA-F-STR-SEAL | SMA Female | Straight | UBR220 Sealed | 18-26.5GHz | Gasketed, pressurized systems |
7 | CW-WR42-SMA-M-RA-SEAL | SMA Male | 90° Right-Angle | UBR220 Sealed | 18-26.5GHz | Gasketed, side entry |
8 | CW-WR42-SMA-F-RA-SEAL | SMA Female | 90° Right-Angle | UBR220 Sealed | 18-26.5GHz | Gasketed, side entry |
9 | CW-WR42-SMA-M-STR-CHK | SMA Male | Straight | UBR220 Choke | 18-26.5GHz | Choke flange, max RF seal |
10 | CW-WR42-SMA-F-STR-CHK | SMA Female | Straight | UBR220 Choke | 18-26.5GHz | Choke flange, max RF seal |
11 | CW-WR42-SMA-M-RA-CHK | SMA Male | 90° Right-Angle | UBR220 Choke | 18-26.5GHz | Choke + right-angle |
12 | CW-WR42-SMA-F-RA-CHK | SMA Female | 90° Right-Angle | UBR220 Choke | 18-26.5GHz | Choke + right-angle |
💡 All twelve models share the same WR42 waveguide port and UBR220 mating pattern. The difference is SMA gender (Male/Female), body orientation (Straight/Right-Angle), and flange type (Flat/Sealed/Choke). Right-angle versions use a precision 90° bend for side-entry routing. Sealed flanges include an integrated gasket groove for pressurized systems. Choke flanges provide maximum RF isolation for high-sensitivity receiver test.
Key Performance (independent Coaxwave test system):
VSWR: ≤ 1.25:1 (18.0–26.5GHz, full band)
Insertion Loss: ≤ 0.30 dB (including waveguide-to-probe transition)
Isolation: ≥ 80 dB (waveguide port to coax outer conductor)
Inspection: 100% VNA full-band S11/S21 sweep + CMM waveguide inner-dimension verification + flange flatness check (≤0.05mm). Each unit ships with an individual test report — your adapter's actual S-parameters. Laser-marked serial numbers guarantee full traceability.
WR42 is the workhorse waveguide for K-band (18–26.5GHz). SMA is the workhorse coaxial interface for test and modular RF. Coaxwave WR42-to-SMA adapters are engineered to connect these two worlds with minimal loss and maximum repeatability. Every adapter is machined, assembled, and tested as a single integrated transition — not a waveguide flange bolted to a coax launcher.
SMA Male Straight — Flat Flange (CW-WR42-SMA-M-STR-FLAT):
SMA plug on coax side, in-line body. UBR220 flat flange. Best for direct connection to VNA test cables or standard panel mounts.
SMA Female Straight — Flat Flange (CW-WR42-SMA-F-STR-FLAT):
SMA jack on coax side, in-line body. UBR220 flat flange. Best for connecting to SMA plug-terminated devices or bulkhead feedthroughs.
SMA Male Right-Angle — Flat Flange (CW-WR42-SMA-M-RA-FLAT):
SMA plug with 90° coax exit. Essential when the DUT or test cable approaches from the side — common in compact ATE fixtures.
SMA Female Right-Angle — Flat Flange (CW-WR42-SMA-F-RA-FLAT):
SMA jack with 90° coax exit. Ideal for side-entry test setups where the DUT presents an SMA male connector.
Sealed Flange Variants (Models 5–8):
UBR220 flange with integrated gasket groove. For pressurized waveguide systems or hermetically sealed enclosures. Eliminates need for separate gasket handling.
Choke Flange Variants (Models 9–12):
UBR220 choke flange design. Provides maximum RF isolation at the flange interface. Essential for high-sensitivity K-band receiver test where even micro-watts of flange leakage degrade NF.
Every WR42-to-SMA adapter undergoes three mandatory 100% tests:
VNA Full-Band S-Parameter Sweep: S11 and S21 measured from 18.0GHz to 26.5GHz. VSWR ≤1.25 and IL ≤0.30dB verified per unit.
CMM Waveguide Dimensional Verification: Inner dimensions (0.420" × 0.170") checked against MIL-DTL-3922. Flange hole pattern and flatness verified.
Flange Flatness Check: UBR220 flange surface inspected for flatness ≤0.05mm. Critical for maintaining RF seal when mated to waveguide components.
No sampling. Each unit ships with an individual test report — your adapter's actual measured S-parameters. Laser-marked serial numbers on every adapter guarantee full traceability.
Frequency Range: 18.0 – 26.5 GHz (K-band)
Impedance: 50Ω ±0.5%
VSWR: ≤ 1.25:1 (full band)
Insertion Loss: ≤ 0.30 dB (including transition)
Isolation: ≥ 80 dB (waveguide port to coax outer conductor)
Waveguide Interface: WR42 per MIL-DTL-3922
Flange Options: UBR220 Flat / Sealed (gasket groove) / Choke — configurable
Flange Flatness: ≤ 0.05 mm
Coax Coupling: SMA, 1/4-36 UNS thread
Coax Torque: 0.9 N·m (8 in-lbs) — use SMA torque wrench
Mounting Hardware: 4× screws (4-40 or 6-32), torque 0.9–1.1 N·m cross-pattern
Waveguide Body: Brass (CuZn), nickel-plated or passivated
Coax Outer Conductor: Passivated stainless steel (SUS303)
Center Contact: Beryllium copper, gold-plated over nickel underplate
Dielectric: PTFE (Teflon®)
Flange: Aluminum or brass, same plating as body
Interface Standard: MIL-DTL-3922 (waveguide), MIL-STD-348 (SMA)
Plating Thickness: Gold ≥ 0.00005" over nickel underplate
Operating Temperature: -55℃ ~ +125℃
Storage Temperature: -65℃ ~ +150℃
Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)
Vibration: MIL-STD-202, Method 204, Condition D
Shock: MIL-STD-202, Method 213, Condition B
RoHS / REACH: Compliant
Quality System: ISO 9001:2015 / AS9100D
Waveguide Side:
Align WR42 port with mating waveguide flange
Use UBR220 cover flange with 4 screws
Tighten in cross-pattern (like lug nuts) to 0.9–1.1 N·m
Always use conductive gaskets between flat flanges for RF seal
Sealed flanges: install O-ring in groove before mating
Choke flanges: ensure choke groove aligns with mating cover flange
Coax Side (SMA):
Screw SMA nut onto mating SMA connector
Torque to 0.9 N·m (8 in-lbs) with SMA torque wrench
Do NOT over-tighten — deforms dielectric → VSWR degrades above 26.5GHz
Right-Angle Orientation:
The 90° bend exits perpendicular to the waveguide broad wall
Plan cable routing accordingly to avoid stress on the SMA joint
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
5G mmWave FR2 Test | CW-WR42-SMA-M-STR-FLAT | Straight, SMA male | VNA direct connect, 24-28GHz |
SatCom K-band Transceiver | CW-WR42-SMA-F-STR-CHK | Choke flange, SMA female | Max RF isolation, bulkhead |
Automotive Radar Module | CW-WR42-SMA-M-RA-SEAL | Sealed RA, SMA male | Pressurized chamber test |
Compact ATE Fixture | CW-WR42-SMA-F-RA-FLAT | Right-angle, SMA female | Side-entry in confined bay |
Aerospace Avionics | CW-WR42-SMA-M-STR-CHK | Choke flange, SMA male | Flight-line, high-sensitivity RX |
Defense EW Receiver | CW-WR42-SMA-F-STR-CHK | Choke flange, low loss | Signal intelligence, max isolation |
Production HPA Test | CW-WR42-SMA-M-RA-FLAT | Right-angle, space-save | High-power amplifier ATE |
National Metrology Lab | CW-WR42-SMA-M-STR-FLAT | Flat flange, metrology grade | Primary K-band standard |
University Research | CW-WR42-SMA-F-RA-FLAT | Right-angle, flexible | Educational K-band experiments |
Field Service Kit | CW-WR42-SMA-M-STR-FLAT | Flat flange, rugged | Portable K-band test set |
12 Standard Models: SMA M/F × Straight/Right-Angle × Flat/Sealed/Choke flange
Flange Options: UBR220 flat, sealed (gasket groove), choke — or custom patterns per drawing
Full Kit: Adapter + UBR220 cover flange + 4 screws + conductive gasket (or O-ring for sealed)
Low-IL Version: Insertion loss ≤ 0.25dB (extended probe optimization, for metrology use)
Extended Band: 17.5–27.0GHz (relaxed VSWR for broader coverage)
Phase-Matched Pairs: Two adapters matched to ±1° for differential K-band systems
Alternate Flange: CPR-42G (gasketed), UG-595/U (choke), or custom bolt pattern
Panel-Mount Version: Fixed coax bulkhead with panel nut for permanent installation
Keyed SMA: Prevents mis-mating in multi-port arrays
Non-Magnetic Version: For EMC chambers and quantum K-band test
Hermetically Sealed: For pressurized waveguide systems (enhanced beyond standard sealed)
Extended Temperature: For thermal chamber calibration (-55℃ to +125℃)
100% VNA Full-Band Characterization: Every adapter measured 18.0-26.5GHz
Individual Test Report: Actual S-parameters (S11, S21) per unit
SN Traceability: Laser-marked unique serial numbers on every adapter
Rapid Prototyping: Standard models 2-3 week shipment; custom 4-6 weeks
Application Engineering: Coaxwave RF engineers provide:
Flange torque and gasket selection guidance
SMA torque best practices for K-band
Waveguide-to-coax calibration plane management
Multi-port array layout for phased K-band systems
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: Mount CW-WR42-SMA-M-STR-FLAT to VNA test port cable (SMA male). Connect waveguide side to WR42 calibration kit or DUT.
Workflow: Torque flange screws cross-pattern (0.9–1.1 N·m). Torque SMA to 0.9 N·m. Run VNA sweep 18.0–26.5GHz.
Why This Adapter: VSWR ≤1.25 ensures calibration residual error stays below 0.5dB. Right-angle version (CW-WR42-SMA-M-RA-FLAT) used when test bay space is limited.
Setup: DUT has WR42 output flange. Use CW-WR42-SMA-F-STR-CHK (choke flange) to transition to SMA test equipment.
Workflow: Choke flange provides maximum RF seal. SMA female accepts DUT's SMA male cable. Quick connect/disconnect for production line.
Why This Adapter: Choke flange eliminates flange leakage that would otherwise appear as a ripple in the DUT's measured S21.
Setup: ATE fixture operates in a pressurized environment. Use CW-WR42-SMA-M-RA-SEAL to connect to DUT.
Workflow: Sealed flange with O-ring maintains pressure integrity. Right-angle body routes cable horizontally, avoiding vertical clearance issues.
Why This Adapter: No performance penalty vs. straight version. Pressure boundary maintained without separate gasket handling.
⚠️ Flange Torque Must Be Even (Cross-Pattern):
Always tighten 4 screws in cross-pattern (like lug nuts on a car)
Uneven torque causes flange warping → RF leakage → degraded VSWR
Torque: 0.9–1.1 N·m for all UBR220 flanges
⚠️ SMA Torque: 0.9 N·m (8 in-lbs) — Never Exceed:
Over-tightening deforms PTFE dielectric → impedance shift → VSWR degrades above 26.5GHz
Under-tightening causes intermittent contact → test repeatability failure
Always use a calibrated SMA torque wrench
⚠️ Choke Flange Orientation:
Choke flanges have a groove on one side — this MUST face the waveguide cavity
Installing a choke flange backwards destroys the RF seal and can damage the mating flat flange
Verify groove depth and orientation before torquing
Keep Waveguide Flanges Clean:
Dust or burrs on flange face cause RF leakage
Clean with IPA and lint-free wipe before every use
Cap waveguide opening when not in use
Frequency: 18.0 – 26.5 GHz (K-band, WR42)
Impedance: 50Ω ±0.5%
VSWR: ≤ 1.25:1 (factory, per unit)
Insertion Loss: ≤ 0.30 dB (including transition)
Adapter Matrix: SMA M/F × Straight/Right-Angle × Flat/Sealed/Choke = 12 standard models
Flange: UBR220-series (Flat / Sealed / Choke, configurable)
Materials: Brass waveguide body + stainless-steel coax + BeCu gold-plated center contact
100% VNA Full-Band S-Parameter Test + CMM Waveguide Verification + Flange Flatness Check + Individual Test Report + SN Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for WR42-to-SMA Selection:
Choke Flange Is Worth the Cost at K-Band: At 26.5GHz, flange leakage of just -40dB can appear as a 0.2dB ripple on your S21 trace. For any receiver or low-noise measurement, the choke flange is not optional — it is mandatory.
The Flange Gasket Is Part of the RF Path: Without a conductive gasket between flat UBR220 flanges, RF leaks at the seam. Always install a gasket. Coaxwave supplies gaskets on request.
SMA Torque at K-Band Is Critical: At 26.5GHz, a poorly torqued SMA connection adds 0.1–0.3dB of unpredictable loss. The 0.9 N·m specification is not a suggestion — it is the condition under which the adapter was characterized.
There is no perfect standard part, only the most suitable solution.
Coaxwave WR42 to SMA Waveguide-to-Coax Adapters are not merely mechanical transitions; they are the engineered bridge between two fundamentally different transmission architectures. We machine every brass body, optimize every probe depth, and verify every S-parameter with "German precision" and "French engineering logic". With twelve standard models covering every SMA gender, orientation, and flange specification, 100% VNA certification, and UBR220-series flanges that mate to any WR42 system, Coaxwave delivers the most suitable waveguide-coax transition for your exact K-band, 5G, SatCom, and defense requirement.
Sales Email: sales@coaxial-rf.com
Company Website: