The WR28 waveguide (26.5-40GHz) is the industry-standard rectangular waveguide for Ka-band. The 2.92mm (K-Type) coaxial connector is rated to 40GHz — making it the ideal coaxial counterpart for the full WR28 frequency range. Unlike the 2.4mm interface, 2.92mm uses a 1/4-36 UNS thread, which is mechanically compatible with SMA and 3.5mm connectors, enabling flexible cross-interface configurations. Coaxwave adapters employ a precision-machined stepped-impedance or fin-line transition structure inside a brass or aluminum housing, with a passivated stainless-steel 2.92mm coaxial interface featuring gold-plated beryllium-copper center contact and PTFE dielectric. The waveguide port is machined to WR28 inner dimensions with a UG-599/U-class cover flange per MIL-DTL-3922.
Frequency & Electrical Architecture:
Parameter | Waveguide Side (WR28) | Coax Side (2.92mm) |
|---|---|---|
Frequency Range | 26.5 – 40 GHz | DC – 40 GHz (interface limit) |
Operating Band | Ka-band (full WR28) | DC – 40 GHz (waveguide-limited) |
VSWR (Typical) | ≤ 1.25:1 (26.5-40GHz) | ≤ 1.20:1 (DC-40GHz) |
Insertion Loss | ≤ 0.25 dB (26.5-40GHz) | — |
Impedance Match | ≈ 50Ω equivalent | 50Ω ±1% |
💡 Frequency Boundary: The adapter operates across the full WR28 band (26.5-40GHz). The 2.92mm coax interface is rated to 40GHz, which perfectly matches the waveguide upper limit. Signals outside 26.5-40GHz will not propagate through the waveguide side. The 1/4-36 UNS thread allows mechanical mating with SMA and 3.5mm connectors — see cross-interface models below.
All Transfer Models (complete WR28-to-2.92mm adapter matrix — native & cross-interface):
No. | Model Name | Waveguide | Coax Interface | Orientation | Freq | Notes |
|---|---|---|---|---|---|---|
1 | CW-WG28-292-M-S | WR28 (UG-599/U) | 2.92mm (M) | Straight | 26.5-40GHz | Native, male plug |
2 | CW-WG28-292-F-S | WR28 (UG-599/U) | 2.92mm (F) | Straight | 26.5-40GHz | Native, female jack |
3 | CW-WG28-292-M-RA | WR28 (UG-599/U) | 2.92mm (M) | Right-Angle | 26.5-40GHz | Right-angle, male |
4 | CW-WG28-292-F-RA | WR28 (UG-599/U) | 2.92mm (F) | Right-Angle | 26.5-40GHz | Right-angle, female |
5 | CW-WG28-292-SMA-M-S | WR28 (UG-599/U) | → SMA (F) direct thread | 26.5-40GHz | Coax-limited to 26.5GHz | |
6 | CW-WG28-292-35-M-S | WR28 (UG-599/U) | → 3.5mm (F) direct thread | 26.5-40GHz | Coax-limited to 26.5GHz | |
7 | CW-WG28-292-24-M-S | WR28 (UG-599/U) | → 2.4mm (F) adapter | 26.5-40GHz | Full band, 2.4mm-limited to 50GHz | |
8 | CW-WG28-292-185-M-S | WR28 (UG-599/U) | → 1.85mm (F) adapter | 26.5-40GHz | Full band, 1.85mm-limited to 67GHz |
💡 Cross-Interface Notes: Models 5 and 6 use the shared 1/4-36 UNS thread — the 2.92mm port can directly accept SMA or 3.5mm plugs mechanically. However, SMA and 3.5mm are electrically capped at 26.5GHz, so the usable coax bandwidth is limited accordingly. Models 7 and 8 use precision transition adapters; the 2.4mm and 1.85mm interfaces exceed 40GHz but the overall frequency remains 26.5-40GHz (waveguide-limited). For full Ka-band coax testing, native 2.92mm output (models 1-4) is recommended.
Key Performance (independent Coaxwave test system):
VSWR: ≤ 1.25:1 (26.5-40GHz, both ports)
Insertion Loss: ≤ 0.25 dB (26.5-40GHz, typical 0.15-0.20 dB straight, +0.1 dB right-angle)
Return Loss: ≥ 19.1 dB (26.5-40GHz)
Impedance Match: 50Ω coaxial reference
Waveguide Flange: UG-599/U-class per MIL-DTL-3922
Inspection: 100% VNA full-band S-parameter sweep (26.5-40GHz) + CMM waveguide inner-dimension verification + flange flatness and integrity check. Each unit ships with an independent factory test data manual — measured S11, S21, and mechanical inspection report. Laser-marked with unique serial number.
In Ka-band systems (26.5-40GHz), waveguide remains the lowest-loss transmission medium for power delivery and antenna feeds, while 2.92mm (K-Type) coaxial is the most widely adopted precision interface for VNA test ports and mmWave instrumentation. Coaxwave WR28-to-2.92mm adapters provide the critical transition between these two domains. These are not repackaged commercial adapters; they are engineered precision transitions with optimized stepped-impedance matching structures that achieve VSWR ≤ 1.25 and insertion loss as low as 0.15 dB across the full WR28 band.
Straight (Inline): Minimum insertion loss (~0.15-0.20 dB), ideal for bench-top VNA test setups and panel-mount applications. The signal path is a direct linear transition from waveguide TE10 mode to coaxial TEM mode.
Right-Angle: 90° coax exit relative to the waveguide flange face. Essential for space-constrained test fixtures, rack-mounted systems, and applications where cable routing requires a perpendicular exit. Slightly higher insertion loss (~0.1 dB additional) due to the bend geometry.
Coaxwave provides 4 native models (2.92mm M/F × Straight/Right-Angle) and 4 cross-interface configurations:
Native (WR28 → 2.92mm, 26.5-40GHz):
Straight Male (M): 2.92mm plug, straight body — most common for VNA port connection
Straight Female (F): 2.92mm jack, straight body — for panel-mount or inline DUT connection
Right-Angle Male (M): 2.92mm plug, 90° exit — space-constrained routing
Right-Angle Female (F): 2.92mm jack, 90° exit — perpendicular panel interface
Cross-Interface (WR28 → 2.92mm + direct thread or adapter):
WR28 → SMA (F): Shared 1/4-36 UNS thread, coax-limited to 26.5GHz
WR28 → 3.5mm (F): Shared 1/4-36 UNS thread, coax-limited to 26.5GHz
WR28 → 2.4mm (F): Via precision transition, full 26.5-40GHz
WR28 → 1.85mm (F): Via precision transition, full 26.5-40GHz
Every WR28-to-2.92mm adapter undergoes three mandatory 100% tests:
VNA Full-Band S-Parameter Sweep (26.5-40GHz): S11 and S21 measured at every frequency point. VSWR and insertion loss verified against ≤ 1.25:1 and ≤ 0.25 dB limits.
CMM Waveguide Verification: Inner dimensions of WR28 aperture checked on coordinate measuring machine against MIL-DTL-3922. Flange flatness and hole pattern verified.
Flange Integrity Check: UG-599/U-class flange surface inspected for flatness ≤ 0.05mm. Thread and tapped-hole integrity confirmed.
No sampling, no "typical" curves. Each unit ships with an independent factory test data manual — your unit's actual S-parameters and CMM data. Laser-marked serial number guarantees full traceability.
Frequency Range: 26.5 – 40 GHz (full WR28 band)
VSWR: ≤ 1.25:1 (26.5-40GHz, both waveguide and coax ports)
Insertion Loss: ≤ 0.25 dB (26.5-40GHz, typical 0.15-0.20 dB straight, +0.1 dB right-angle)
Return Loss: ≥ 19.1 dB (26.5-40GHz)
Impedance: 50Ω coaxial reference
Waveguide Mode: TE10 (dominant)
Coax Interface Frequency: 2.92mm rated to 40GHz (perfectly matched to WR28 band)
Waveguide Interface: WR28 per MIL-DTL-3922
Flange Type: UG-599/U-class cover flange (4× 4-40 tapped holes, 0.312" depth)
Flange Flatness: ≤ 0.05mm
Coax Coupling: 1/4-36 UNS thread (2.92mm / K-Type standard)
Coax Coupling Torque: 0.8–1.1 N·m (7.1–9.7 in-lbs) per MIL-STD-348
Mating Cycles: ≥ 500 (2.92mm precision interface)
Mounting: 4× screw holes for flange attachment; coax panel-mount optional
Weight: ~42g (straight), ~50g (right-angle)
Waveguide Body: Brass (CuZn), nickel-plated or passivated
Coax Outer Conductor: Passivated stainless steel (SUS303)
Inner Conductor (Coax): Beryllium copper, gold-plated over nickel underplate
Dielectric (Coax): PTFE (Teflon®)
Transition Structure: Stepped-impedance or fin-line matching circuit
Flange Material: Aluminum or brass, per MIL-DTL-3922
Plating Thickness: Gold ≥ 0.00005" over nickel underplate
Operating Temperature: -55℃ ~ +125℃ (body surface up to +125℃ at full power)
Storage Temperature: -65℃ ~ +150℃
Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)
Vibration: MIL-STD-202, Method 204, Condition D
Shock: MIL-STD-202, Method 213, Condition B
Flange Standard: MIL-DTL-3922 (UG-599/U-class)
Coax Standard: MIL-STD-348 (2.92mm/K-Type)
RoHS / REACH: Compliant
Quality System: ISO 9001:2015 / AS9100D
Waveguide Connection:
Use UG-599/U-class cover flange with 4× 4-40 screws
Torque screws evenly in cross-pattern to 0.9-1.1 N·m
Use conductive gasket for pressurized waveguide systems
Ensure flange faces are clean and undamaged before mating
2.92mm Coax Connection:
Use a dedicated 2.92mm torque wrench — 0.8–1.1 N·m (7.1–9.7 in-lbs)
Do NOT use SMA wrench set to 0.9 N·m max — while the thread is the same (1/4-36 UNS), the K-Type torque range is slightly higher. 0.9 N·m is acceptable but at the lower edge of the recommended window
Finger-tighten first, then torque to specified range
Mechanical Compatibility with SMA / 3.5mm:
2.92mm shares 1/4-36 UNS thread with SMA and 3.5mm — they will mechanically mate
SMA and 3.5mm are electrically capped at 26.5GHz — for any measurement above 26.5GHz, use native 2.92mm only
Usage Notes:
100% VNA tested 26.5-40GHz — independent factory test data manual ships with every unit
Clean waveguide flange with IPA and lint-free swabs before mating
Cap 2.92mm connector when not in use
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
Ka-band VNA Calibration | CW-WG28-292-M-S | Straight, 2.92mm M, VSWR ≤1.25 | VNA port to WR28 calibration kit |
5G mmWave FR2 Base Station Test | CW-WG28-292-F-S | Straight, 2.92mm F | Base station OTA test interface |
SatCom Ka-band HPA Test | CW-WG28-292-M-RA | Right-angle, 2.92mm M | HPA output to waveguide feed |
Automotive Radar (35GHz) | CW-WG28-292-F-RA | Right-angle, 2.92mm F | Radar module waveguide feed |
Defense EW Receiver Test | CW-WG28-292-M-S | Straight, rugged | EW system waveguide port test |
Legacy SMA VNA (26.5GHz) | CW-WG28-292-SMA-M-S | WR28-to-SMA, 26.5GHz limit | SMA VNA to WR28 DUT |
Legacy 3.5mm VNA (26.5GHz) | CW-WG28-292-35-M-S | WR28-to-3.5mm, 26.5GHz limit | 3.5mm VNA to WR28 DUT |
2.4mm VNA (Full Ka-band) | CW-WG28-292-24-M-S | WR28-to-2.4mm, 26.5-40GHz | 2.4mm VNA to WR28 system |
1.85mm VNA (Full Ka-band) | CW-WG28-292-185-M-S | WR28-to-1.85mm, 26.5-40GHz | 1.85mm VNA to WR28 DUT |
Production ATE (High Volume) | CW-WG28-292-M-S | Straight, 500+ cycles | Automated Ka-band device test |
Native Interfaces: WR28 waveguide (UG-599/U-class) → 2.92mm coax (M/F)
Orientations: Straight (inline) / Right-Angle (90° coax exit)
Cross-Interface: Direct-thread SMA/3.5mm, precision-transition 2.4mm/1.85mm
Frequency: 26.5-40GHz (WR28 band, perfectly matched to 2.92mm rating)
Ultra-Low VSWR (Metrology): Target ≤ 1.15:1 (26.5-40GHz) for calibration-grade applications
Ultra-Low Insertion Loss: Optimized fin-line structure, target ≤ 0.15 dB (straight)
Phase-Matched Pairs: Two adapters matched to ±2° for differential/multi-channel Ka-band systems
Alternative Flange Types: UG-599A/U, UG-600/U, or custom flange patterns on request
Bulkhead Mount: Panel-mount version with O-ring seal for environmental protection
Custom Orientation: 45° or other angles between waveguide and coax axes
Integrated Alignment Pins: For precision repeatable mating in ATE fixtures
Non-Magnetic Version: For EMC test chambers and quantum computing RF test
Extended Temperature: Consult Coaxwave engineering for extreme-environment specifications
Hermetically Sealed Flange: For pressurized Ka-band waveguide systems
100% VNA Full-Band S-Parameter Test (26.5-40GHz): Every adapter verified
CMM Waveguide Inspection: Inner dimensions and flange flatness data in factory manual
Independent Factory Test Data Manual: Your unit's actual S11, S21, and CMM report
SN Traceability: Laser-marked unique serial number
Rapid Prototyping: Standard models 3-4 week shipment; custom 6-8 weeks
Application Engineering: Coaxwave RF engineers provide:
Waveguide flange selection guidance (UG-599/U-class vs. alternatives)
2.92mm torque and handling best practices
Cross-interface frequency planning (SMA/3.5mm 26.5GHz limit awareness)
Ka-band calibration setup recommendations
Tip
"There is no perfect standard part, only the most suitable solution."
VNA Calibration with WR28 Devices:
Use CW-WG28-292-M-S (straight, male) to connect a 2.92mm VNA port to a WR28 calibration kit or DUT. The adapter's VSWR ≤ 1.25 and IL ≤ 0.25 dB ensure minimal calibration error. For right-angle routing in compact test fixtures, use CW-WG28-292-M-RA.
WR28-to-2.4mm VNA (Full Ka-band):
Use CW-WG28-292-24-M-S. The 2.4mm interface supports up to 50GHz; the overall frequency remains 26.5-40GHz (waveguide-limited). This provides excellent electrical performance for full Ka-band VNA measurements.
SatCom Ka-band HPA Output Test:
Use CW-WG28-292-M-RA (right-angle, male) to route the HPA output from a WR28 waveguide feed to a 2.92mm spectrum analyzer or power meter. The right-angle exit simplifies cable management in rack-mounted test setups.
5G FR2 OTA Test Interface:
Use CW-WG28-292-F-S (straight, female) as the panel-mount interface between a 5G mmWave OTA chamber's WR28 feed and external 2.92mm test equipment.
35GHz Automotive Radar Module Test:
Use CW-WG28-292-F-RA (right-angle, female) for perpendicular connection to the radar module's WR28 antenna feed. The 90° exit accommodates space-constrained module test fixtures.
Defense EW System Waveguide Port Test:
Use CW-WG28-292-M-S (straight, male) for direct connection to WR28 EW system ports. Rugged brass body withstands field and lab environments.
2.92mm Coax Torque: 0.8–1.1 N·m (7.1–9.7 in-lbs):
Per MIL-STD-348 for K-Type connectors
Do NOT use SMA wrench set to 0.9 N·m max — it is at the lower edge of the recommended range. For optimal repeatability at 40GHz, use a properly calibrated 2.92mm torque wrench in the full 0.8–1.1 N·m window
Overtightening beyond 1.1 N·m deforms the air-dielectric interface
Undertightening causes intermittent contact → return loss degradation above 26.5GHz
⚠️ SMA/3.5mm Mechanical Compatibility ≠ Electrical Rating:
2.92mm shares 1/4-36 UNS thread with SMA and 3.5mm — they will mechanically mate
SMA and 3.5mm are electrically capped at 26.5GHz — for any measurement above 26.5GHz, use native 2.92mm only
Cross-interface models 5 and 6 (SMA/3.5mm) are explicitly limited to 26.5GHz on the coax side
Flange Mating Requires Even Torque:
UG-599/U-class flange uses 4× 4-40 screws. Tighten in cross-pattern to 0.9-1.1 N·m
Uneven torque causes flange warping → RF leakage → degraded VSWR
100% VNA Tested — Trust Your Data:
Every Coaxwave WR28-to-2.92mm adapter ships with an independent factory test data manual
Your unit's actual S11 and S21 from 26.5-40GHz is in the manual — not a "typical" curve
Frequency: 26.5 – 40 GHz (full WR28 Ka-band, perfectly matched to 2.92mm 40GHz rating)
VSWR: ≤ 1.25:1 (26.5-40GHz)
Insertion Loss: ≤ 0.25 dB (straight), ≤ 0.35 dB (right-angle)
Interfaces: WR28 UG-599/U-class flange → 2.92mm coax (M/F, straight/right-angle)
8 Standard Transfer Models + custom configurations on request
Materials: Brass waveguide body + passivated stainless 2.92mm + BeCu gold-plated contacts + PTFE dielectric
100% VNA Full-Band S-Parameter Test + CMM Waveguide Inspection + Flange Integrity Verification + Independent Factory Test Data Manual + SN Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for WR28-to-2.92mm Adapter Selection:
2.92mm is the Perfect Coaxial Match for WR28: Unlike 2.4mm (rated to 50GHz) or 1.85mm (rated to 67GHz), the 2.92mm interface is rated exactly to 40GHz — the same as the WR28 upper limit. This makes it the most bandwidth-matched coaxial interface for Ka-band waveguide systems, with no wasted frequency headroom and the lowest possible VSWR transition.
Shared Thread Does NOT Mean Shared Bandwidth: The 1/4-36 UNS thread is shared with SMA and 3.5mm, which tempts users to connect those interfaces directly. Remember: SMA and 3.5mm are capped at 26.5GHz. If your measurement requires the full 26.5-40GHz WR28 band, you MUST use native 2.92mm or a transition to 2.4mm/1.85mm on the coax side.
0.8–1.1 N·m is the Correct Torque Window: While a SMA wrench at 0.9 N·m will physically tighten the connector, it sits at the lower edge of the K-Type specification. For optimal repeatability at 40GHz — where a 0.1 dB error matters — use a dedicated 2.92mm torque wrench set to the full 0.8–1.1 N·m range.
There is no perfect standard part, only the most suitable solution.
Coaxwave WR28 to 2.92mm waveguide-to-coax adapters are not merely mechanical transitions; they are the engineered bridge between Ka-band waveguide transmission and 2.92mm (K-Type) mmWave coaxial test systems. We machine every brass waveguide body and passivated stainless-steel coax interface with "German precision" and verify every unit's S-parameters and mechanical dimensions with "French engineering logic". With straight and right-angle orientations, male/female genders, and a complete cross-interface matrix — plus 100% VNA certification from 26.5 to 40GHz — Coaxwave delivers the most suitable waveguide-to-coax adapter for your exact Ka-band, 5G, SatCom, radar, and defense requirement.
Sales Email: sales@coaxial-rf.com