







Architecture Bridge — Waveguide to 2.4mm mmWave
The WR15 rectangular waveguide (0.148" × 0.074" inner dimensions) defines the full V-band from 50–75GHz. The 2.4mm (K-Type extended) coaxial interface extends to 50GHz and shares the M7×0.75 coupling thread with 1.85mm — making it the most robust mmWave coaxial option for full V-band test equipment. Coaxwave's transition design uses a precision stepped-impedance probe inside the waveguide to couple energy from the TE₁₀ mode to the TEM coaxial mode. The probe position and depth are optimized via HFSS simulation to achieve <0.6dB insertion loss and VSWR ≤1.35 across the full 50–75GHz WR15 band.
Frequency Coverage:
Parameter | Specification |
|---|---|
Frequency Range | 50 – 75 GHz (Full V-band, WR15 native band) |
Waveguide | WR15 (MIL-DTL-3922) |
Coax Interface | 2.4mm / K-Type extended (IEEE Std 287™-2007) |
Impedance | 50Ω ±0.5% |
Flange Type | UG-385/U (Round, Cover or Chassis) |
All Transfer Models (complete WR15-to-2.4mm adapter matrix — 2.4mm M/F × straight/right-angle):
No. | Model Name | 2.4mm Gender | Body Style | Freq | Notes |
|---|---|---|---|---|---|
1 | CW-WR15-24-M-STR | 2.4mm Male | Straight | 50-75GHz | In-line, UG-385/U round flange |
2 | CW-WR15-24-F-STR | 2.4mm Female | Straight | 50-75GHz | In-line, UG-385/U round flange |
3 | CW-WR15-24-M-RA | 2.4mm Male | 90° Right-Angle | 50-75GHz | Space-save, UG-385/U round flange |
4 | CW-WR15-24-F-RA | 2.4mm Female | 90° Right-Angle | 50-75GHz | Space-save, UG-385/U round flange |
💡 All four models share the same WR15 waveguide port and UG-385/U round flange. The difference is 2.4mm gender (Male/Female) and body orientation (Straight/Right-Angle). Right-angle versions use a precision 90° bend for side-entry routing where test-bay space is constrained. At 75GHz the air wavelength is ~4mm — the right-angle transition is engineered with this constraint in mind. This adapter unlocks the full WR15 bandwidth to 75GHz, unlike the WR15-to-2.92mm version (capped at 67GHz).
Key Performance (independent Coaxwave test system):
VSWR: ≤ 1.35:1 (50–75GHz, full band)
Insertion Loss: ≤ 0.60 dB (including waveguide-to-probe transition)
Isolation: ≥ 80 dB (waveguide port to coax outer conductor)
Inspection: 100% VNA full-band S11/S21 sweep (50–75GHz) + CMM waveguide inner-dimension verification + flange integrity and gas-tightness check (flatness ≤0.05mm). Each unit ships with an individual test report — your adapter's actual S-parameters. Laser-marked serial numbers guarantee full traceability.
WR15 is the standard waveguide for the full V-band (50–75GHz). 2.4mm (K-Type extended) is the most widely deployed coaxial interface that covers the entire WR15 frequency range. Coaxwave WR15-to-2.4mm adapters connect these two architectures with minimal loss and maximum repeatability. Every adapter is machined, assembled, and tested as a single integrated transition — not a waveguide flange bolted to a coax launcher.
2.4mm Male Straight (CW-WR15-24-M-STR):
2.4mm plug on coax side, in-line body. Best for direct connection to VNA test cables or panel-mounted 2.4mm jacks across 50–75GHz.
2.4mm Female Straight (CW-WR15-24-F-STR):
2.4mm jack on coax side, in-line body. Best for connecting to 2.4mm plug-terminated devices or bulkhead feedthroughs.
2.4mm Male Right-Angle (CW-WR15-24-M-RA):
2.4mm plug with 90° coax exit. Essential when the DUT or test cable approaches from the side — common in compact ATE fixtures.
2.4mm Female Right-Angle (CW-WR15-24-F-RA):
2.4mm jack with 90° coax exit. Ideal for side-entry test setups where the DUT presents a 2.4mm male connector.
Every WR15-to-2.4mm adapter undergoes three mandatory 100% tests:
VNA Full-Band S-Parameter Sweep: S11 and S21 measured from 50GHz to 75GHz. VSWR ≤1.35 and IL ≤0.60dB verified per unit.
CMM Waveguide Dimensional Verification: Inner dimensions (0.148" × 0.074") checked against MIL-DTL-3922. Flange hole pattern and flatness verified.
Flange Integrity & Gas-Tightness Check: UG-385/U round flange surface inspected for flatness ≤0.05mm. Gas-tightness verified where specified. Critical for maintaining RF seal at V-band frequencies.
No sampling. Each unit ships with an individual test report — your adapter's actual measured S-parameters. Laser-marked serial numbers on every adapter guarantee full traceability.
Frequency Range: 50 – 75 GHz (Full V-band, WR15 native band)
Impedance: 50Ω ±0.5%
VSWR: ≤ 1.35:1 (full band)
Insertion Loss: ≤ 0.60 dB (including transition)
Isolation: ≥ 80 dB (waveguide port to coax outer conductor)
Waveguide Interface: WR15 per MIL-DTL-3922
Flange Type: UG-385/U (Round, Cover or Chassis, configurable)
Flange Flatness: ≤ 0.05 mm
Coax Coupling: 2.4mm (K-Type extended), M7 × 0.75 metric thread
Coax Torque: 0.45 N·m (4 in-lbs) — use 2.4mm torque wrench ONLY
Mounting Hardware: 4× screws (4-40 or 6-32), torque 0.9–1.1 N·m cross-pattern
Waveguide Body: Brass (CuZn), nickel-plated or passivated
Coax Outer Conductor: Passivated stainless steel (SUS303)
Center Contact: Beryllium copper, gold-plated over nickel underplate
Dielectric: PEI (Polyetherimide) with precision air-gap transition
Flange: Aluminum or brass, same plating as body
Interface Standard: MIL-DTL-3922 (waveguide), IEEE Std 287™-2007 (2.4mm)
Plating Thickness: Gold ≥ 0.00005" over nickel underplate
Operating Temperature: -55℃ ~ +125℃
Storage Temperature: -65℃ ~ +150℃
Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)
Vibration: MIL-STD-202, Method 204, Condition D
Shock: MIL-STD-202, Method 213, Condition B
RoHS / REACH: Compliant
Quality System: ISO 9001:2015 / AS9100D
Waveguide Side:
Align WR15 port with mating waveguide flange
Use UG-385/U round cover flange with 4 screws
Tighten in cross-pattern (like lug nuts) to 0.9–1.1 N·m
Always use conductive gaskets between flanges for RF seal at V-band
Coax Side (2.4mm):
Screw 2.4mm nut onto mating 2.4mm connector
Torque to 0.45 N·m (4 in-lbs) with 2.4mm torque wrench
⚠️ CRITICAL: 2.4mm uses M7×0.75 metric thread — NOT compatible with SMA/3.5mm/2.92mm wrenches (1/4-36 UNS). A SMA wrench will cross-thread or crack the 2.4mm coupling nut instantly.
Right-Angle Orientation:
The 90° bend exits perpendicular to the waveguide broad wall
Plan cable routing accordingly to avoid stress on the 2.4mm joint
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
5G mmWave FR3 Test | CW-WR15-24-M-STR | Straight, 2.4mm male | VNA direct connect, 50-75GHz |
SatCom V-band Transceiver | CW-WR15-24-F-STR | Straight, 2.4mm female | Bulkhead feedthrough |
Automotive Imaging Radar | CW-WR15-24-M-RA | Right-angle, 2.4mm male | Side-entry in compact chamber |
Compact ATE Fixture | CW-WR15-24-F-RA | Right-angle, 2.4mm female | Side-entry in confined bay |
Aerospace Avionics | CW-WR15-24-M-STR | Straight, rugged | Flight-line V-band test |
Defense EW Receiver | CW-WR15-24-F-STR | Straight, low loss | Signal intelligence system |
Production HPA Test | CW-WR15-24-M-RA | Right-angle, space-save | High-power amplifier ATE |
National Metrology Lab | CW-WR15-24-M-STR | Straight, metrology grade | Primary full V-band standard |
University Research Lab | CW-WR15-24-F-RA | Right-angle, flexible | Educational V-band experiments |
Field Service Kit | CW-WR15-24-M-STR | Straight, rugged | Portable V-band test set |
4 Standard Models: 2.4mm M/F × Straight/Right-Angle
Flange Options: UG-385/U round cover, chassis, or custom patterns per customer drawing
Full Kit: Adapter + UG-385/U cover flange + 4 screws + conductive gasket
Low-IL Version: Insertion loss ≤ 0.50dB (extended probe optimization, for metrology use)
Phase-Matched Pairs: Two adapters matched to ±1.5° for differential V-band systems
Alternate Flange: CPR-15G (gasketed), UG-385A/U (choke), or custom bolt pattern
Panel-Mount Version: Fixed coax bulkhead with panel nut for permanent installation
Keyed 2.4mm Coupling Nut: Prevents mis-mating in multi-port arrays
Non-Magnetic Version: For EMC chambers and quantum V-band test
Hermetically Sealed: For pressurized waveguide systems
Extended Temperature: For thermal chamber calibration (-55℃ to +125℃)
100% VNA Full-Band Characterization: Every adapter measured 50-75GHz
Individual Test Report: Actual S-parameters (S11, S21) per unit
SN Traceability: Laser-marked unique serial numbers on every adapter
Rapid Prototyping: Standard models 2-3 week shipment; custom 4-6 weeks
Application Engineering: Coaxwave RF engineers provide:
Flange torque and gasket selection guidance
2.4mm torque best practices for full V-band
Waveguide-to-coax calibration plane management
Multi-port array layout for phased V-band systems
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: Mount CW-WR15-24-M-STR to VNA test port cable (2.4mm male). Connect waveguide side to WR15 calibration kit or DUT.
Workflow: Torque flange screws cross-pattern (0.9–1.1 N·m). Torque 2.4mm to 0.45 N·m using the correct 2.4mm wrench. Run VNA sweep 50–75GHz.
Why This Adapter: VSWR ≤1.35 ensures calibration residual error stays controlled across the full V-band. Right-angle version (CW-WR15-24-M-RA) used when test bay space is limited.
Setup: DUT has WR15 output flange. Use CW-WR15-24-F-STR to transition to 2.4mm test equipment.
Workflow: Flange connection with conductive gasket. 2.4mm female accepts DUT's 2.4mm male cable. Quick connect/disconnect for production line.
Why This Adapter: 0.6dB max IL preserves signal integrity for full V-band transceiver test. Unlike 2.92mm adapters, this covers the entire WR15 band to 75GHz.
Setup: ATE fixture has horizontal 2.4mm test ports. Use CW-WR15-24-M-RA to connect to vertical WR15 DUT port.
Workflow: Right-angle body routes cable horizontally, avoiding vertical clearance issues. No cable stress.
Why This Adapter: Space-constrained fixtures benefit from 90° exit. No performance penalty vs. straight version at 75GHz.
⚠️ 2.4mm Torque: 0.45 N·m (4 in-lbs) — Use ONLY the Included 2.4mm Wrench:
The 2.4mm coupling thread is M7×0.75 metric — NOT compatible with SMA/3.5mm/2.92mm wrenches (1/4-36 UNS)
A SMA wrench will cross-thread or crack the 2.4mm coupling nut instantly — irreparable damage
1.85mm wrenches share the same M7×0.75 thread and 0.45 N·m torque — technically compatible, but always use the Coaxwave-supplied wrench for traceability
⚠️ This Adapter Covers the FULL WR15 Band (50–75GHz):
Unlike WR15-to-2.92mm adapters (capped at 67GHz), this adapter uses the full WR15 waveguide bandwidth
For any measurement above 67GHz, this is the correct choice — not the 2.92mm version
⚠️ Flange Torque Must Be Even (Cross-Pattern):
Always tighten 4 screws in cross-pattern (like lug nuts on a car)
Uneven torque causes flange warping → RF leakage → degraded VSWR
Torque: 0.9–1.1 N·m for all UG-385/U flanges
Keep Waveguide Flanges Clean:
Dust or burrs on flange face cause RF leakage
Clean with IPA and lint-free wipe before every use
Cap waveguide opening when not in use
Frequency: 50 – 75 GHz (Full V-band, WR15 native band)
Impedance: 50Ω ±0.5%
VSWR: ≤ 1.35:1 (factory, per unit)
Insertion Loss: ≤ 0.60 dB (including transition)
Adapter Matrix: 2.4mm M/F × Straight/Right-Angle = 4 standard models
Flange: UG-385/U Round (configurable)
Materials: Brass waveguide body + stainless-steel coax + BeCu gold-plated center contact
100% VNA Full-Band S-Parameter Test + CMM Waveguide Verification + Flange Integrity Check + Individual Test Report + SN Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for WR15-to-2.4mm Selection:
This Is the Only WR15 Adapter That Covers the Full 50–75GHz Band: The 2.92mm version tops out at 67GHz. If your measurement requires 67–75GHz, this 2.4mm adapter is the correct choice. No compromise.
The 2.4mm Wrench Is Not Interchangeable with SMA: M7×0.75 metric vs. 1/4-36 UNS — forcing a SMA wrench on a 2.4mm nut will destroy the interface instantly. Always use the Coaxwave-supplied 2.4mm torque wrench.
The Flange Gasket Is Part of the RF Path: Without a conductive gasket between UG-385/U flanges, RF leaks at the seam. At 75GHz, even micro-watts of leakage appear as ripple on your S21 trace. Always install a gasket. Coaxwave supplies gaskets on request.
There is no perfect standard part, only the most suitable solution.
Coaxwave WR15 to 2.4mm Waveguide-to-Coax Adapters are not merely mechanical transitions; they are the engineered bridge between two fundamentally different transmission architectures. We machine every brass body, optimize every probe depth, and verify every S-parameter with "German precision" and "French engineering logic". With four standard models covering every 2.4mm gender and orientation need, 100% VNA certification, and a UG-385/U flange that mates to any WR15 system, Coaxwave delivers the most suitable waveguide-coax transition for your exact full V-band, 5G, SatCom, and defense requirement.
Sales Email: sales@coaxial-rf.com
Company Website: