Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable TouchstoneCoaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable TouchstoneCoaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone
  • Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone
  • Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone
  • Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone
  • 1/3
  • Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone
  • Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone
  • Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone

Coaxwave UHF (PL-259/SO-239) Connector DC-500MHz VSWR≤1.25 | 5/8-24 UNEF | SN-Traceable Touchstone

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave UHF Series (PL-259/SO-239) are classic 50Ω threaded coaxial connectors operating DC–300MHz (premium to 500MHz). 5/8"-24 UNEF thread. VSWR ≤1.25. Peak power >1kW (500V DWV). Brass nickel/silver body, brass/phosphor bronze silver/gold center, PTFE/polypropylene dielectric. 100% SN-laser-marked; factory Touchstone downloadable. Built to "German precision, French engineering logic."
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave UHF Series connectors are the classic 50Ω threaded coaxial interface originally invented by Amphenol engineers in the 1930s, continuing the legacy of the PL-259 (plug) and SO-239 (chassis receptacle) gold-standard combination. Designed with a 5/8"-24 UNEF threaded coupling, the interface operates from DC–300MHz (with premium versions extending to DC–500MHz). While the nominal system impedance is 50Ω, the interface itself is a non-constant impedance transition (typically ~35Ω at the mating plane) — a deliberate design characteristic that has proven reliable across decades of high-power VHF/UHF applications. Despite the name "UHF," the practical operating range is below 300MHz, making it the absolute workhorse for amateur radio (HAM), CB, marine VHF, land mobile radio, and broadcast PA systems.

The product line covers 17 standard models across cable-mount, chassis-mount, same-series adapters, right-angle configurations, and cross-series transitions:

No.

Model Family

Configuration

Frequency

Notes

1

CW-UHF-M-RG58

PL-259 Plug, RG58

DC–300MHz

Cable-mount, standard

2

CW-UHF-M-RG213

PL-259 Plug, RG213

DC–300MHz

Cable-mount, high-power

3

CW-UHF-M-RG8

PL-259 Plug, RG8

DC–300MHz

Cable-mount, low-loss

4

CW-UHF-M-RG142

PL-259 Plug, RG142

DC–500MHz

Cable-mount, double-braid

5

CW-UHF-M-RU400

PL-259 Plug, RU400

DC–500MHz

Cable-mount, foam-dielectric

6

CW-UHF-F-4HF

SO-239 Jack, 4-Hole Flange

DC–300MHz

Chassis panel mount

7

CW-UHF-F-TH

SO-239 Jack, Threaded

DC–300MHz

Chassis threaded mount

8

CW-UHF-F-BH

SO-239 Jack, Bulkhead

DC–300MHz

Wall feedthrough

9

CW-UHF-MM-ADP

UHF M ↔ M Barrel (PL-259↔PL-259 via SO-239 barrel)

DC–300MHz

In-line gender bridge

10

CW-UHF-FF-ADP

UHF F ↔ F Barrel (SO-239↔SO-239 via PL-259 barrel)

DC–300MHz

In-line coupler

11

CW-UHF-N-MF

UHF to N-Type M-F

DC–300MHz*

Cross-series bridge

12

CW-UHF-BNC-MF

UHF to BNC M-F

DC–300MHz*

Cross-series bridge

13

CW-UHF-SMA-MF

UHF to SMA M-F

DC–300MHz*

Cross-series bridge

14

CW-UHF-TNC-MF

UHF to TNC M-F

DC–300MHz*

Cross-series bridge

15

CW-UHF-FTYP-MF

UHF to F-Type M-F (50Ω→75Ω)

DC–300MHz*

Impedance-transition bridge

16

CW-UHF-MM-RA

UHF M ↔ M 90° Right-Angle

DC–300MHz

Space-constrained routing

17

CW-UHF-MF-RA

UHF M ↔ F 90° Right-Angle

DC–300MHz

Right-angle port saver

* Cross-series bandwidth limited by the lower-frequency interface. N-Type, SMA, TNC, and F-Type each impose their own upper-frequency constraints.

💡 Every model is 100% VNA-tested from 10 MHz to its rated upper frequency, laser-marked with a unique serial number, and linked to a downloadable factory Touchstone (.s2p) file.

Key Performance (Coaxwave UHF Series specification):

  • Frequency Range: DC–300MHz (standard); DC–500MHz (premium RG142/RU400)

  • VSWR: ≤ 1.25 (DC–300MHz)

  • Insertion Loss: ≤ 0.10 dB @ 100MHz (typical, per mated pair)

  • Peak Power Capacity: > 1kW (500V dielectric withstanding voltage)

  • Durability: ≥ 500 mating cycles

🎯 Core Positioning: The Enduring Legacy of PL-259 / SO-239

The UHF connector is the most recognized RF interface in the history of radio communication — a design that has remained virtually unchanged since the 1930s because it simply works. Coaxwave UHF Series brings German precision manufacturing to this timeless interface. The 5/8"-24 UNEF threaded coupling provides a rock-solid mechanical connection capable of handling peak power exceeding 1kW — making it the definitive choice for high-power VHF/UHF base stations, amplifier chains, and antenna feedlines. While the interface exhibits a non-constant impedance of approximately 35Ω at the mating plane (a well-documented characteristic of the UHF design), this has negligible impact below 300MHz and contributes to the connector's legendary ruggedness and ease of assembly in field conditions.

⚡ Complete 17-Model Interface Matrix

① Cable-Mount — PL-259 Plugs (5 Models)

  • PL-259 for RG58 (DC–300MHz): The most common PL-259 termination. RG58's 5mm OD fits the standard UHF barrel. Ideal for mobile rigs and antenna rotators.

  • PL-259 for RG213 (DC–300MHz): Heavy-duty termination for high-power base stations. RG213's lower loss preserves signal integrity on long feedlines.

  • PL-259 for RG8 (DC–300MHz): Similar to RG213 but with a foam dielectric variant. Preferred for low-loss antenna installations.

  • PL-259 for RG142 (DC–500MHz): Double-braided silver-plated cable. Extends the UHF interface to 500MHz for premium applications.

  • PL-259 for RU400 (DC–500MHz): Foam-dielectric, low-loss cable. The modern replacement for RG213 in high-performance installations.

② Chassis-Mount — SO-239 Jacks (3 Models)

  • SO-239 4-Hole Flange (DC–300MHz): The classic panel-mount receptacle. Four mounting holes provide maximum mechanical stability for amplifier front panels and antenna switches.

  • SO-239 Threaded Mount (DC–300MHz): Chassis-threaded insert for ultra-low-profile installations where flange clearance is unavailable.

  • SO-239 Bulkhead (DC–300MHz): Sealed feedthrough for outdoor enclosures and tower-mounted equipment.

③ Same-Series Adapters (2 Models)

  • UHF M ↔ M Barrel — PL-259 to PL-259 (DC–300MHz): A double-female SO-239 barrel with two PL-259 plugs creates an in-line M-M extension. Essential for joining two SO-239-terminated cables.

  • UHF F ↔ F Barrel — SO-239 to SO-239 (DC–300MHz): A double-male PL-259 barrel with two SO-239 jacks creates an in-line F-F coupler. Used for chassis-to-chassis connections.

④ Right-Angle Adapters (2 Models)

  • UHF M ↔ M 90° Right-Angle (DC–300MHz): Routes the coaxial path perpendicular to the panel. Critical for tight amplifier enclosures where straight PL-259 protrusion would interfere with adjacent equipment.

  • UHF M ↔ F 90° Right-Angle (DC–300MHz): Converts a panel-mounted SO-239 to a side-exit port. Reduces strain on the cable entry point.

⑤ Cross-Series Adapters (5 Models)

  • UHF to N-Type M-F (DC–300MHz*): Bridges legacy UHF equipment to modern N-Type test gear. Bandwidth limited by UHF side.

  • UHF to BNC M-F (DC–300MHz*): Adapts UHF antenna systems to BNC oscilloscope or spectrum analyzer inputs.

  • UHF to SMA M-F (DC–300MHz*): Connects UHF base-station equipment to SMA-portable analyzers.

  • UHF to TNC M-F (DC–300MHz*): Threaded BNC alternative for vibration-prone mobile installations.

  • UHF to F-Type M-F (DC–300MHz*): 50Ω-to-75Ω impedance-transition bridge for connecting CATV test equipment to UHF radio systems. Note: significant mismatch will occur if not properly compensated.

🛡️ Coaxwave Quality Barrier — SN Traceability & Touchstone Delivery

Every UHF connector and adapter undergoes four mandatory 100% controls:

  1. 100% VNA Full-Band S-Parameter Test: Swept from 10 MHz to 300MHz (or 500MHz for premium). S11, S21 recorded. VSWR verified at 1GHz-step resolution.

  2. Touchstone File Generation: Measured S-parameters saved as a .s2p file — compatible with Keysight, Rohde & Schwarz, Anritsu VNA software.

  3. Laser Marking & Anti-Counterfeit Code: Each connector body laser-etched with unique serial number + 8-digit anti-counterfeit code. Etched into brass nickel or silver body.

  4. SN Traceability: Enter SN + 8-digit code to download the factory Touchstone file, test configuration, and material certification.


Electrical Performance

  • Characteristic Impedance: 50Ω nominal (system); ~35Ω at mating plane (non-constant impedance transition)

  • Frequency Range: DC–300MHz (standard); DC–500MHz (premium RG142/RU400)

  • VSWR: ≤ 1.25 (DC–300MHz)

  • Insertion Loss: ≤ 0.10 dB @ 100MHz (typical, per mated pair)

  • Dielectric Withstanding Voltage: 500 V RMS

  • Peak Power Capacity: > 1kW (continuous duty at VHF/UHF)

  • Insulation Resistance: ≥ 1000 MΩ (at 500 V DC)

  • Center Contact Resistance: ≤ 10 mΩ

  • Outer Contact Resistance: ≤ 5 mΩ

  • RF Leakage: ≥ 60 dB isolation (DC–300MHz)

Mechanical Performance

  • Coupling Mechanism: 5/8"-24 UNEF threaded (both ends)

  • Recommended Torque: Hand-tight + 1/4 turn with wrench (approximately 10–15 in-lbs / 1.1–1.7 N·m) — never over-tighten; brass threads strip easily

  • Mating Cycles: ≥ 500

  • Center Contact Retention: ≥ 10 N (captivated)

  • Mounting Options: Cable-mount (RG58/RG142/RG213/RG8/RU400), 4-hole flange, threaded chassis, bulkhead, right-angle adapters

Materials & Structure

  • Body / Shell: Brass, nickel-plated (standard) or silver-plated (premium)

  • Center Contact: Brass or phosphor bronze, silver-plated (standard) or gold-plated (premium)

  • Dielectric: PTFE (Teflon) or polypropylene

  • Plating: Nickel per QQ-N-290; Silver per ASTM B700; Gold per MIL-G-45204

  • Laser Marking: Unique SN + 8-digit code, etched into body

Environment & Compliance

  • Operating Temperature: -65℃ ~ +165℃

  • RF Interface Compliance: MIL-STD-348 (UHF/PL-259/SO-239 dimensional reference)

  • RoHS / REACH: Compliant (silver/gold plating exemptions per Annex III)

  • Quality System: ISO 9001:2015

  • Traceability: 100% SN-marked; Touchstone file downloadable via SN + 8-digit code

Adaptation & Installation

  • ⚠️ Torque — Hand-Tight + 1/4 Turn MAX: The 5/8"-24 UNEF thread is cut into soft brass. Over-torquing strips the threads instantly. Hand-tight plus a gentle 1/4-turn wrench is sufficient for RF integrity.

  • ⚠️ Non-Constant Impedance — Acceptable Below 300MHz: The UHF interface has a ~35Ω characteristic at the mating plane. This is a known design trait, not a defect. At frequencies below 300MHz, the electrical length of the mismatch is negligible. Do not use above 500MHz without understanding the VSWR implications.

  • ⚠️ 50Ω System Only: UHF is a 50Ω interface. Never use in 75Ω systems — severe mismatch will occur. The UHF-to-F-Type adapter is an exception but requires impedance-matching compensation.

  • ⚠️ Cable Preparation — Follow Strip Dimensions: For PL-259 termination, the outer jacket must be stripped to expose the braid, and the braid must be folded back over the barrel before soldering the center pin. Incorrect preparation causes high VSWR and mechanical failure.

  • ⚠️ SN + 8-Digit Code Required for Touchstone: Both SN and 8-digit code must be available to download the factory Touchstone file. Lost codes cannot be recovered.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

Amateur Radio Base Station

CW-UHF-M-RG213 (PL-259)

High-power, low-loss

HF/VHF amplifier to antenna

Marine VHF Radio

CW-UHF-F-4HF (SO-239 Flange)

Corrosion-resistant, stable

Bridge-to-bridge comms panel

CB Mobile Radio

CW-UHF-M-RG58 (PL-259)

Compact, flexible

Vehicle antenna feed

Broadcast PA System

CW-UHF-F-BH (Bulkhead)

Sealed feedthrough

Outdoor speaker line

Land Mobile Radio (LMR)

CW-UHF-M-RU400 (PL-259)

Modern low-loss replacement

Repeater site antenna

Legacy Equipment Test

CW-UHF-N-MF (to N-Type)

Bridge to modern VNA

Vintage radio restoration

Standard Matrix & Extensions

  • 17 Standard Models: 5 cable-mount PL-259 + 3 chassis SO-239 + 2 same-series barrels + 2 right-angle + 5 cross-series

  • Two Performance Tiers: Standard (DC–300MHz, nickel/PTFE) / Premium (DC–500MHz, silver/polypropylene)

  • Full Kit: Connector + SN card + anti-counterfeit code + Touchstone download instruction + torque chart + cable-strip drawing

⚡ Electrical Performance Customization

  • Low-PIM Option: For land-mobile infrastructure requiring PIM < -140dBc

  • Extended-Range Premium: VSWR ≤ 1.15 for broadcast PA systems

Structural Customization

  • Custom Cable Assemblies: RG58/RG142/RG213/RG8/RU400 pre-terminated to print

  • Custom Flange Patterns: Non-standard hole spacing for vintage equipment panels

  • Custom Barrel Lengths: Extended M-M or F-F adapters for unique spacing requirements

️ Material & Environmental Customization

  • All-Silver Construction: For maximum conductivity in high-power amplifier chains

  • Gold-Plated Center: For corrosion-free connections in marine environments

SN Traceability & Service

  • 100% Unique Serial Number: Laser-etched on every body

  • Touchstone File Download: Enter SN + 8-digit code to access factory S2P file

  • Test Report Includes: VNA model, calibration method, sweep range (10MHz–300/500MHz), S11/S21 data

  • Rapid Prototyping: Standard 2–3 weeks; custom cable assemblies 3–4 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • UHF torque guidance (hand-tight + 1/4 turn)

    • PL-259 cable preparation training (RG58/RG213/RG8 strip dimensions)

    • Non-constant impedance explanation for frequencies above 300MHz

    • Cross-series adapter bandwidth limits (N-Type, BNC, SMA, TNC, F-Type)

    • Touchstone file interpretation for VHF/UHF de-embedding


Tip

"There is no perfect standard part, only the most suitable solution."


Amateur Radio HF/VHF Base Station — PL-259 on RG213

  • Setup: HAM operator building a 100W HF station with a 20m beam antenna. 30m feedline run. Use CW-UHF-M-RG213.

  • Workflow: PL-259 soldered to RG213 using standard strip-and-fold technique. Center pin soldered, barrel tightened to SO-239 on amplifier. SWR measured at 1.1:1 on 14MHz. After 200 field adjustments, connection remains solid.

  • Why This Connector: RG213's low loss preserves signal over 30m. Brass nickel body withstands outdoor exposure. Peak power >1kW provides headroom for amplifier upgrades.

Marine VHF Bridge-to-Bridge — SO-239 4-Hole Flange

  • Setup: Commercial vessel refitting VHF radio. Panel mount required for IP54-rated wheelhouse. Use CW-UHF-F-4HF.

  • Workflow: SO-239 flange-mounted on aluminum panel. PL-259 cable hand-tightened + 1/4 turn. System VSWR ≤1.2 at 156MHz. Survives salt-spray environment for 5+ years.

  • Why This Connector: 4-hole flange provides secure panel mounting. Brass nickel resists corrosion. Touchstone enables exact de-embedding for shore-station compliance testing.

Land Mobile Radio Repeater — Bulkhead Feedthrough

  • Setup: Public safety repeater site. Tower-mounted equipment requires weatherproof feedthrough. Use CW-UHF-F-BH.

  • Workflow: Bulkhead connector mounted on NEMA enclosure wall. PL-259 cables on both sides. System operates at 100W continuous on 150MHz. 500+ mating cycles over 10 years.

  • Why This Connector: Sealed bulkhead prevents moisture ingress. PTFE dielectric stable from -65℃ to +165℃. Silver-plated option available for lowest loss.

⚠️ Usage Red Lines

  • ⚠️ TORQUE — HAND-TIGHT + 1/4 TURN MAXIMUM:

    • Brass threads strip instantly if over-tightened. Never use a wrench beyond finger-tight + 1/4 turn.


  • ⚠️ FREQUENCY LIMIT — 300MHz PRACTICAL MAXIMUM:

    • Despite the name "UHF," this interface is only practical below 300MHz. Premium versions to 500MHz require careful VSWR management.


  • ⚠️ 50Ω SYSTEM ONLY:

    • UHF is a 50Ω interface. Never use in 75Ω systems without impedance compensation.


  • ⚠️ CABLE PREPARATION — STRIP AND FOLD:

    • The braid must be folded back over the barrel before soldering. Incorrect preparation causes high VSWR.


  • ⚠️ SN + 8-DIGIT CODE REQUIRED FOR TOUCHSTONE:

    • Both SN and 8-digit code must be available to download the factory Touchstone file. Lost codes cannot be recovered.



Tip: "There is no perfect standard part, only the most suitable solution."

Coaxwave UHF (PL-259/SO-239) Series connectors are engineered as the definitive 50Ω high-power VHF/UHF interface — brass nickel or silver bodies, silver or gold center contacts, and PTFE/polypropylene dielectrics deliver VSWR ≤1.25 with full SN traceability. Every connector is VNA-verified, laser-marked, and ships with a downloadable Touchstone file embodying "German precision, French engineering logic." With 17 standard models spanning cable-mount, chassis-mount, barrels, right-angle adapters, and cross-series transitions, Coaxwave delivers the most suitable UHF solution for your exact requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com