Coaxwave SMA Same-Series Adapter Matrix is a comprehensive 50Ω interconnect solution engineered for laboratories, ATE facilities, and production environments where SMA is the universal interface. The SMA (SubMiniature version A) connector, defined by MIL-STD-348A Fig.310 and IEC 60169-15, uses a 1/4-36 UNS threaded coupling and is the most widely deployed RF connector in the 0–18GHz (and up to 26.5GHz in precision constructions) range. Coaxwave offers both General Grade (DC–18GHz, VSWR ≤1.05+0.005×f(GHz)) for everyday lab use and Precision Grade (DC–26.5GHz, VSWR ≤1.15) for metrology and aerospace calibration.
Beyond simple in-line extension, Coaxwave SMA adapters serve a critical role as Connector Savers — sacrificial protective interfaces that absorb the mechanical wear of daily connect/disconnect cycles, shielding the expensive native SMA ports on VNAs, signal generators, and spectrum analyzers from torque stress, center-pin damage, and dielectric contamination.
The product line covers 12 standard models across four mechanical families:
No. | Model Family | SMA End A | SMA End B | Configuration | Max Freq | Notes |
|---|---|---|---|---|---|---|
1 | CW-SMA-MM-STR | SMA Male | SMA Male | Straight | DC–26.5GHz* | In-line barrel / extender |
2 | CW-SMA-MF-STR | SMA Male | SMA Female | Straight | DC–26.5GHz* | Most common gender bridge |
3 | CW-SMA-FF-STR | SMA Female | SMA Female | Straight | DC–26.5GHz* | In-line coupler |
4 | CW-SMA-MM-RA | SMA Male | SMA Male | 90° Right-Angle | DC–26.5GHz* | Space-constrained routing |
5 | CW-SMA-MF-RA | SMA Male | SMA Female | 90° Right-Angle | DC–26.5GHz* | Right-angle test port |
6 | CW-SMA-FF-RA | SMA Female | SMA Female | 90° Right-Angle | DC–26.5GHz* | Right-angle coupler |
7 | CW-SMA-MF-BH | SMA Male | SMA Female | Bulkhead | DC–26.5GHz* | Panel feedthrough |
8 | CW-SMA-FF-BH | SMA Female | SMA Female | Bulkhead | DC–26.5GHz* | Panel F-F feedthrough |
9 | CW-SMA-MF-HB | SMA Male | SMA Female | Hermetic Bulkhead | DC–26.5GHz* | Glass-sealed, pressurized |
10 | CW-SMA-FF-HB | SMA Female | SMA Female | Hermetic Bulkhead | DC–26.5GHz* | Hermetic F-F |
11 | CW-SMA-MF-CS | SMA Male | SMA Female | Connector Saver (Extended) | DC–26.5GHz* | Extra-length port protector |
12 | CW-SMA-MM-CS | SMA Male | SMA Male | Connector Saver Barrel | DC–26.5GHz* | Double-ended port protection |
* Precision Grade: DC–26.5GHz, VSWR ≤1.15. General Grade: DC–18GHz, VSWR ≤1.05+0.005×f(GHz). Both tiers available across all 12 models — specify grade at order.
💡 Every model is 100% VNA-tested to its rated upper frequency, laser-marked with a unique serial number, and linked to a downloadable factory Touchstone (.s2p) file.
Key Performance (Coaxwave SMA Same-Series specification):
Frequency Range: DC–18GHz (General); DC–26.5GHz (Precision)
VSWR: ≤ 1.05+0.005×f(GHz) General; ≤ 1.15:1 Precision (straight)
Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)
Durability: ≥ 500 mating cycles (General); ≥ 1000 cycles (Precision, Connector Saver)
Coupling Torque: 0.8–1.1 N·m (calibrated torque wrench)
SMA connectors are the lingua franca of RF engineering — from benchtop VNAs to satellite transponders, from USB-powered spectrum analyzers to phased-array beamformers. But the ubiquity of SMA creates a hidden cost: every connect/disconnect cycle wears the equipment's native port. A misaligned coupling nut, an over-torqued wrench, or a contaminated center pin can destroy a $15,000 VNA port module. Coaxwave SMA adapters — especially the Connector Saver variants — act as a sacrificial layer. When the adapter eventually degrades after 500–1000 cycles, you replace a $30–$80 adapter, not the instrument port.
① Straight (3 Genders)
SMA M ↔ M / M ↔ F / F ↔ F: In-line adapters for cable extension, gender adaptation, and daily calibration. The M-F is the lab standard: VNA SMA port → SMA test cable. The M-M barrel extends cable reach. The F-F coupler joins two SMA male cables.
② 90° Right-Angle (3 Genders)
SMA M ↔ M / M ↔ F / F ↔ F: Route RF lines in space-constrained enclosures — ATE fixtures, portable analyzers, and rack-mounted equipment where a straight adapter would place stress on the cable or panel. Right-angle VSWR ≤ 1.25 (slightly higher than straight due to bend geometry).
③ Bulkhead (2 Genders)
SMA M ↔ F / F ↔ F: Thru-wall feedthrough for environmental test chambers, sealed enclosures, and ATE frames. Provides panel grounding and strain relief.
④ Hermetic Bulkhead (2 Genders)
SMA M ↔ F / F ↔ F: Glass-sealed bulkhead with helium-leak-rated isolation. For pressurized environments, space simulation chambers, and hermetically sealed equipment housings. Leak rate ≤ 1×10⁻⁸ atm·cc/s He.
⑤ Connector Saver (2 Dedicated Models)
SMA M ↔ F (Extended): Extra-length barrel positions the wear surface further from the instrument port, maximizing protection. The most popular Connector Saver configuration.
SMA M ↔ M (Barrel): Double-ended protection for connecting two cables while shielding both ends' native ports.
Every SMA Adapter undergoes four mandatory 100% controls:
100% VNA Full-Band S-Parameter Test: Swept from 10 MHz to rated frequency (18GHz General / 26.5GHz Precision). S11, S21 recorded. VSWR and insertion loss verified.
Touchstone File Generation: Measured S-parameters saved as a .s2p file — compatible with Keysight, Rohde & Schwarz, Anritsu, Copper Mountain VNA software.
Laser Marking & Anti-Counterfeit Code: Each adapter body laser-etched with unique serial number + 8-digit anti-counterfeit code. Etched into SUS303 or brass — survives 1000+ cycles.
SN-Traceability Portal: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability to download the factory Touchstone file, test configuration, and material certification.
SMA connectors are the lingua franca of RF engineering — from benchtop VNAs to satellite transponders, from USB-powered spectrum analyzers to phased-array beamformers. But the ubiquity of SMA creates a hidden cost: every connect/disconnect cycle wears the equipment's native port. A misaligned coupling nut, an over-torqued wrench, or a contaminated center pin can destroy a $15,000 VNA port module. Coaxwave SMA adapters — especially the Connector Saver variants — act as a sacrificial layer. When the adapter eventually degrades after 500–1000 cycles, you replace a $30–$80 adapter, not the instrument port.
① Straight (3 Genders)
SMA M ↔ M / M ↔ F / F ↔ F: In-line adapters for cable extension, gender adaptation, and daily calibration. The M-F is the lab standard: VNA SMA port → SMA test cable. The M-M barrel extends cable reach. The F-F coupler joins two SMA male cables.
② 90° Right-Angle (3 Genders)
SMA M ↔ M / M ↔ F / F ↔ F: Route RF lines in space-constrained enclosures — ATE fixtures, portable analyzers, and rack-mounted equipment where a straight adapter would place stress on the cable or panel. Right-angle VSWR ≤ 1.25 (slightly higher than straight due to bend geometry).
③ Bulkhead (2 Genders)
SMA M ↔ F / F ↔ F: Thru-wall feedthrough for environmental test chambers, sealed enclosures, and ATE frames. Provides panel grounding and strain relief.
④ Hermetic Bulkhead (2 Genders)
SMA M ↔ F / F ↔ F: Glass-sealed bulkhead with helium-leak-rated isolation. For pressurized environments, space simulation chambers, and hermetically sealed equipment housings. Leak rate ≤ 1×10⁻⁸ atm·cc/s He.
⑤ Connector Saver (2 Dedicated Models)
SMA M ↔ F (Extended): Extra-length barrel positions the wear surface further from the instrument port, maximizing protection. The most popular Connector Saver configuration.
SMA M ↔ M (Barrel): Double-ended protection for connecting two cables while shielding both ends' native ports.
Every SMA Adapter undergoes four mandatory 100% controls:
100% VNA Full-Band S-Parameter Test: Swept from 10 MHz to rated frequency (18GHz General / 26.5GHz Precision). S11, S21 recorded. VSWR and insertion loss verified.
Touchstone File Generation: Measured S-parameters saved as a .s2p file — compatible with Keysight, Rohde & Schwarz, Anritsu, Copper Mountain VNA software.
Laser Marking & Anti-Counterfeit Code: Each adapter body laser-etched with unique serial number + 8-digit anti-counterfeit code. Etched into SUS303 or brass — survives 1000+ cycles.
SN-Traceability Portal: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability to download the factory Touchstone file, test configuration, and material certification.
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
Daily VNA Calibration | CW-SMA-MF-CS (Precision) | Connector Saver, >1000 cycles | Lab SOLT, port protection |
ATE Production Fixture | CW-SMA-MF-BH (Precision) | Bulkhead, panel mount | Module test rack |
Environmental Chamber | CW-SMA-MF-HB (Precision) | Hermetic, pressurized | Temperature-cycling DUT |
Portable Test Equipment | CW-SMA-MF-RA (General) | Right-angle, compact | Handheld analyzer internal |
Cable Extension | CW-SMA-MM-STR (General) | M-M barrel | In-line reach extension |
F-F Gender Adaptation | CW-SMA-FF-STR (General) | F-F coupler | Quick cable join |
Space Simulation | CW-SMA-FF-HB (Precision) | Hermetic F-F, leak-rated | Vacuum chamber feedthrough |
12 Standard Models: 3 straight + 3 right-angle + 2 bulkhead + 2 hermetic + 2 Connector Saver
Two Performance Tiers: General (DC–18GHz, VSWR≤1.05+0.005f) / Precision (DC–26.5GHz, VSWR≤1.15)
Full Kit: Adapter + SN card + anti-counterfeit code + Touchstone download instruction + torque wrench recommendation
Ultra-Precision Grade: VSWR ≤ 1.10 for national metrology institute applications
Phase-Matched Sets: Multiple adapters matched for TRL calibration at 18–26.5GHz
Custom Right-Angle Orientation: 45°, 135°, or custom bend planes for dense enclosures
Extended-Length Connector Saver: Extra body length for deep-reach port protection
2-Hole Flange: Available as build-to-order (based on bulkhead platform)
All-SUS303 Construction: For maximum corrosion resistance (replaces brass in General Grade)
Heavy Gold Plating: 50μ" gold for >2000-cycle ATE environments
All-PEI Dielectric: For low-outgassing space-flight applications (replaces PTFE)
100% Unique Serial Number: Laser-etched on every body
Touchstone File Download: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability
Test Report Includes: VNA model, calibration method, sweep range, S11/S21 data
Rapid Prototyping: Standard 2–3 weeks; custom 4–5 weeks
Application Engineering: Coaxwave RF engineers provide:
Connector Saver replacement scheduling based on cycle count
Torque procedure (0.8–1.1 N·m, calibrated wrench only)
Hermetic installation and leak-rate verification guidance
Touchstone file interpretation for de-embedding
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: Aerospace lab, 26.5GHz VNA with SMA modules. Daily SOLT calibration. Use CW-SMA-MF-CS (Precision Grade).
Workflow: Connector Saver torqued to VNA port (1.0 N·m). SMA test cable connected to saver (1.0 N·m). SOLT performed. S2P file imported as fixture model. After 1000 cycles, VSWR drift < 0.03. VNA port remains pristine.
Why This Adapter: Extended-length Connector Saver positions wear surface away from instrument port. >1000 cycle life = 2+ years of daily use. Touchstone enables exact de-embedding.
Setup: Satellite module production, 200 units/day. Test fixture requires panel-mounted SMA reference. Use CW-SMA-MF-BH (Precision Grade).
Workflow: Adapter bulkhead-mounted on fixture wall. SMA male faces DUT board. SMA female faces operator cable. 200 DUTs/day. S21 repeatability ≤ 0.04 dB over 6 months.
Why This Adapter: Panel mount provides secure reference plane. Precision grade ensures VSWR ≤1.15. SUS303 body survives production floor.
Setup: Thermal-vacuum chamber, DUT inside at 10⁻⁶ Torr. External SMA instrumentation. Use CW-SMA-FF-HB (Precision Grade).
Workflow: Hermetic bulkhead mounted on chamber wall. SMA female on both sides. Glass seal verified ≤1×10⁻⁸ atm·cc/s He. Chamber pumped down. S-parameters measured at 18GHz. No pressure loss.
Why This Adapter: Hermetic seal maintains vacuum integrity. 26.5GHz bandwidth covers all test frequencies. Gold-plated BeCu ensures reliability in vacuum.
⚠️ SMA TORQUE — 0.8–1.1 N·m MAXIMUM:
Over-torquing beyond 1.1 N·m permanently deforms the PTFE dielectric and center contact alignment. Always use a calibrated torque wrench.
⚠️ CONNECTOR SAVER REPLACEMENT — TRACK CYCLES:
Connector Savers are sacrificial. Replace every 500–1000 cycles or when VSWR exceeds specification. Use SN portal to track.
⚠️ HERMETIC INSTALLATION — DO NOT OVER-COMPRESS GLASS SEAL:
Torque on panel side must not exceed 0.8 N·m. Over-compression cracks the glass-to-metal hermetic seal.
⚠️ SN + 8-DIGIT CODE REQUIRED FOR TOUCHSTONE:
Both SN and 8-digit code must be entered at www.coaxial-rf.com/sn-traceability. Lost codes cannot be recovered.
Tip: "There is no perfect standard part, only the most suitable solution."
Coaxwave SMA Same-Series Adapters are engineered as the definitive 50Ω SMA interconnect ecosystem — from precision-grade metrology to hermetic space applications — SUS303 or Ni-brass bodies, BeCu gold-plated centers (30μ"), and PTFE dielectrics deliver VSWR ≤1.15 (Precision) with full SN traceability. Every adapter is VNA-verified, laser-marked, and ships with a downloadable Touchstone file embodying "German precision, French engineering logic." With 12 standard models spanning straight, right-angle, bulkhead, hermetic, and Connector Saver configurations in two performance tiers, Coaxwave delivers the most suitable SMA solution for your exact requirement.
Sales Email: sales@coaxial-rf.com
Company Website: