Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration MetrologyCoaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration MetrologyCoaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology
  • Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology
  • Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology
  • Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology
  • 1/3
  • Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology
  • Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology
  • Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology

Coaxwave 2.4mm Metrology-Grade Adapter | 50Ω DC-50GHz | VSWR ≤1.08 | IL ≤0.04√f dB | Repeatability <-48dB | 2.4mm/1.85mm/2.92mm/3.5mm/SMA/N Cross-Series | VNA Calibration Metrology

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 2.4mm Metrology-Grade Adapter is the highest-precision product in the adapter matrix for VNA calibration, metrology traceability, and precision testing, 50Ω characteristic impedance, DC–50GHz. Stainless steel passivated body + BeCu gold-plated center contact + PEI/PTFE dielectric support. Coaxwave metrology-grade lapping and assembly process achieves factory VSWR ≤1.08:1, insertion loss ≤0.04√f(GHz) dB, repeatability better than -48dB. Available in 2.4mm same-series M-M/M-F/F-F and 2.4mm ↔ 1.85mm/2.92mm/3.5mm/SMA/N-type cross-series full matrix, supplied with metrology torque wrench and calibration data sheet. The definitive interconnect for VNA calibration kits, national metrology labs, 5G/6G mmWave test, and phased-array T/R component precision test.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Architecture — The DC–50GHz Reference Standard

The 2.4mm interface (IEEE Std 287™-2007) with M7×0.75 metric thread is the most widely deployed coaxial standard for the 18–50GHz range. Coaxwave's metrology-grade execution goes beyond the standard: stainless steel passivated body, beryllium copper gold-plated center contact, and PEI/PTFE dielectric support are assembled under controlled torque and cleanliness conditions. The result: VSWR ≤1.08:1, insertion loss ≤0.04√f(GHz) dB, and repeatability better than -48dB — performance levels that place these adapters in the same league as calibration standards, not ordinary inline components.

All Transfer Models (complete 2.4mm adapter matrix — same-series & cross-series, all with M-M / M-F / F-F gender combinations):

No.

Model Name

Series

Gender

Freq

Notes

1

CW-24-24-M-M

2.4mm ↔ 2.4mm

Male-Male

DC-50GHz

In-line barrel, VNA port extension

2

CW-24-24-M-F

2.4mm ↔ 2.4mm

Male-Female

DC-50GHz

Bullet / gender-changer, minimal length

3

CW-24-24-F-F

2.4mm ↔ 2.4mm

Female-Female

DC-50GHz

In-line barrel, ATE fixture routing

4

CW-24-185-M-M

2.4mm ↔ 1.85mm

Male-Male

DC-50GHz

Cross-series, shared M7×0.75 thread

5

CW-24-185-M-F

2.4mm ↔ 1.85mm

Male-Female

DC-50GHz

Cross-series, shared thread

6

CW-24-185-F-F

2.4mm ↔ 1.85mm

Female-Female

DC-50GHz

Cross-series, shared thread

7

CW-24-292-M-M

2.4mm ↔ 2.92mm

Male-Male

DC-40GHz

Cross-series, 2.92mm limited

8

CW-24-292-M-F

2.4mm ↔ 2.92mm

Male-Female

DC-40GHz

Cross-series, 2.92mm limited

9

CW-24-292-F-F

2.4mm ↔ 2.92mm

Female-Female

DC-40GHz

Cross-series, 2.92mm limited

10

CW-24-35-M-M

2.4mm ↔ 3.5mm

Male-Male

DC-26.5GHz

Cross-series, 3.5mm limited

11

CW-24-35-M-F

2.4mm ↔ 3.5mm

Male-Female

DC-26.5GHz

Cross-series, 3.5mm limited

12

CW-24-35-F-F

2.4mm ↔ 3.5mm

Female-Female

DC-26.5GHz

Cross-series, 3.5mm limited

13

CW-24-SMA-M-M

2.4mm ↔ SMA

Male-Male

DC-26.5GHz

Cross-series, SMA limited

14

CW-24-SMA-M-F

2.4mm ↔ SMA

Male-Female

DC-26.5GHz

Cross-series, SMA limited

15

CW-24-SMA-F-F

2.4mm ↔ SMA

Female-Female

DC-26.5GHz

Cross-series, SMA limited

16

CW-24-N-M-M

2.4mm ↔ N-Type

Male-Male

DC-18GHz

Cross-series, N-Type limited

17

CW-24-N-M-F

2.4mm ↔ N-Type

Male-Female

DC-18GHz

Cross-series, N-Type limited

18

CW-24-N-F-F

2.4mm ↔ N-Type

Female-Female

DC-18GHz

Cross-series, N-Type limited

💡 All 18 models share the same Coaxwave metrology-grade 2.4mm interface on the 2.4mm side. Cross-series models are bounded by the lower-grade interface frequency limit. The 2.4mm ↔ 1.85mm combination is unique: both interfaces share the M7×0.75 thread and 0.45 N·m torque, making them mechanically and electrically seamless up to 50GHz. All adapters ship with the Coaxwave metrology torque wrench and individual calibration data sheet.

Key Performance (Coaxwave metrology-grade process):

  • VSWR: ≤ 1.08:1 (DC–50GHz, same-series)

  • Insertion Loss: ≤ 0.04√f(GHz) dB (typical, same-series)

  • Repeatability: Better than -48 dB (connection-to-connection S21 variation)

  • Mating Cycles: ≥ 500 (mechanical durability verified)

Inspection: 100% VNA full-band S11/S21 sweep (DC–50GHz) + CMM interface dimensional verification + repeatability verification per unit. Each adapter ships with an individual calibration data sheet — your adapter's actual S-parameters and repeatability data. Laser-marked serial numbers guarantee full traceability.

🎯 Core Positioning: The VNA Calibration Reference

Coaxwave 2.4mm Metrology-Grade Adapters are purpose-built for vector network analyzer calibration, metrology traceability, and precision test applications where the adapter must not introduce measurable error. Every manufacturing step — from stainless steel passivation to BeCu center contact gold plating to PEI/PTFE dielectric support molding — is controlled to metrology standards. The assembly process uses calibrated torque tools and cleanroom-grade handling to ensure repeatability better than -48dB.

⚡ Complete Adapter Matrix

Same-Series 2.4mm ↔ 2.4mm (Models 1–3):

  • Male-Male (CW-24-24-M-M): In-line barrel for VNA port extension or joining two 2.4mm female cables. Primary choice for national metrology labs.

  • Male-Female (CW-24-24-M-F): Bullet / gender-changer with minimal length. Lowest reflection configuration for direct DUT-to-cable connection.

  • Female-Female (CW-24-24-F-F): In-line barrel for joining two 2.4mm male cables. Used in ATE fixture routing.

Cross-Series 2.4mm ↔ 1.85mm (Models 4–6):

  • Electrically DC–50GHz on both sides. Both interfaces share M7×0.75 thread and 0.45 N·m torque. Mechanically and electrically seamless — the only difference is the interface standard designation. Ideal for bridging 2.4mm VNA ports to 1.85mm calibration standards.

Cross-Series 2.4mm ↔ 2.92mm (Models 7–9):

  • Electrically bounded to 40GHz (2.92mm limit). 2.92mm uses 1/4-36 UNS thread. The adapter provides a controlled impedance transition between M7×0.75 and 1/4-36 UNS thread standards.

Cross-Series 2.4mm ↔ 3.5mm (Models 10–12):

  • Electrically bounded to 26.5GHz (3.5mm limit). 3.5mm uses 1/4-36 UNS thread. Enables connection from 2.4mm instrumentation to 3.5mm DUTs.

Cross-Series 2.4mm ↔ SMA (Models 13–15):

  • Electrically bounded to 26.5GHz (SMA limit). SMA uses 1/4-36 UNS thread. The most common cross-series need for legacy test equipment integration.

Cross-Series 2.4mm ↔ N-Type (Models 16–18):

  • Electrically bounded to 18GHz (N-Type limit). N-Type uses 1/4-28 UNS thread. Provides a robust, low-cost bridge from precision 2.4mm instrumentation to general-purpose N-Type test equipment.

🛡️ Coaxwave Metrology Barrier

Every 2.4mm Metrology-Grade Adapter undergoes four mandatory 100% controls:

  1. 100% VNA Full-Band S-Parameter Sweep: S11 and S21 measured from DC to 50GHz. VSWR ≤1.08:1 verified per unit on same-series models.

  2. CMM Interface Dimensional Inspection: Outer conductor inner diameter, center conductor outer diameter, and position tolerance checked against IEEE Std 287™-2007 Class A.

  3. Repeatability Verification: Connection-disconnection cycle test confirms S21 variation better than -48dB at 50GHz.

  4. Mechanical Durability Validation: Mating cycle test confirms ≥500 cycles without performance degradation.

Each unit ships with an individual calibration data sheet — your adapter's actual S-parameters and repeatability data. Laser-marked serial numbers on every adapter guarantee full traceability. The Coaxwave metrology torque wrench (M7×0.75, 0.45 N·m) is included with every adapter.


Electrical Performance

  • Frequency Range: DC – 50 GHz (same-series); cross-series limited by lower-grade interface

  • Impedance: 50Ω ±0.5%

  • VSWR: ≤ 1.08:1 (same-series, DC–50GHz)

  • Insertion Loss: ≤ 0.04√f(GHz) dB (typical, same-series)

  • Repeatability: Better than -48 dB (connection-to-connection S21 variation at 50GHz)

  • Isolation: ≥ 100 dB (connector port to outer conductor)

Mechanical Performance

  • Interface Standard: IEEE Std 287™-2007 (2.4mm)

  • Coupling Thread: M7 × 0.75 mm (metric)

  • Coupling Nut Torque: 0.45 N·m (4 in-lbs) — use included Coaxwave 2.4mm torque wrench

  • Mating Cycles: ≥ 500 (mechanical durability verified)

  • Engagement: Minimum 5-thread full engagement before torque application

Materials & Structure

  • Outer Conductor: Passivated stainless steel (SUS303)

  • Center Contact: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PEI (Polyetherimide) / PTFE composite support

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

  • Dimensional Control: Per IEEE Std 287™-2007 Class A (outer ID, center OD, position tolerance)

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • Thread Engagement:

    • Always ensure minimum 5-thread engagement before applying torque

    • Hand-start the M7×0.75 thread — never force

    • If resistance is felt before 5 threads, stop and inspect for cross-threading


  • Torque Application:

    • Use ONLY the included Coaxwave 2.4mm torque wrench (0.45 N·m / 4 in-lbs)

    • ⚠️ CRITICAL: M7×0.75 is NOT compatible with SMA/3.5mm/2.92mm wrenches (1/4-36 UNS). A SMA wrench will cross-thread or crack the 2.4mm coupling nut instantly.

    • 1.85mm shares the same M7×0.75 thread — mechanically compatible, but always use the Coaxwave-supplied wrench for calibration traceability.


  • Mating Hygiene:

    • Inspect center contact and dielectric for debris before every connection

    • Use compressed air or lint-free swab if contamination is visible

    • Cap both ends when not in use



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

VNA Calibration Kit

CW-24-24-M-F

Male-female bullet, VSWR ≤1.08

Calibration standards interconnection

National Metrology Lab

CW-24-24-M-M

Male-male, repeatability <-48dB

VNA port extension, primary standard

5G/6G mmWave Test

CW-24-24-F-F

Female-female, low loss

DUT-to-cable, DC-50GHz

Phased-Array T/R Test

CW-24-185-M-F

2.4mm-to-1.85mm, shared thread

T/R module to 1.85mm test set

SatCom Transceiver

CW-24-292-F-F

2.4mm-to-2.92mm

Legacy 2.92mm equipment bridge

Defense EW Receiver

CW-24-35-M-M

2.4mm-to-3.5mm

Signal intelligence, 26.5GHz

Semiconductor ATE

CW-24-SMA-M-F

2.4mm-to-SMA

Probe station to SMA test set

Production HPA Test

CW-24-N-M-M

2.4mm-to-N-Type

Amplifier ATE, 18GHz

University Research

CW-24-SMA-F-F

2.4mm-to-SMA

Educational, DC-26.5GHz

Field Service Kit

CW-24-24-M-F

Male-female bullet

Portable mmWave test set

Standard Matrix & Extensions

  • 18 Standard Models: 2.4mm same-series (M-M, M-F, F-F) + cross-series to 1.85mm, 2.92mm, 3.5mm, SMA, N-Type (each in M-M, M-F, F-F)

  • Full Kit: Adapter + protective caps + Coaxwave metrology torque wrench (M7×0.75, 0.45 N·m) + individual calibration data sheet

⚡ Electrical Performance Customization

  • Ultra-Low VSWR Version: VSWR ≤ 1.05:1 (extended selection + individual optimization, for national metrology use)

  • Phase-Matched Pairs: Two adapters matched to ±1° at 50GHz for differential phased-array systems

Structural Customization

  • Panel-Mount Version: Fixed bulkhead with panel nut for permanent installation

  • Keyed Coupling Nut: Prevents mis-mating in multi-port arrays

  • Extended Length Barrel: For applications requiring specific spacing between mating faces

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum mmWave test

  • Hermetically Sealed: For pressurized systems

  • Extended Temperature: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every adapter measured DC–50GHz (same-series)

  • Individual Calibration Data Sheet: Actual S-parameters and repeatability data per unit

  • SN Traceability: Laser-marked unique serial numbers on every adapter

  • Rapid Prototyping: Standard models 2-3 week shipment; custom 4-6 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • 2.4mm torque and repeatability best practices

    • Cross-series frequency boundary guidance

    • VNA calibration plane management

    • Multi-port phased-array test layout


Tip

"There is no perfect standard part, only the most suitable solution."


VNA Calibration — National Metrology (DC–50GHz)

  • Setup: Mount CW-24-24-M-F between VNA test port (2.4mm female) and calibration kit or DUT cable.

  • Workflow: Hand-start M7×0.75 thread both ends. Torque each to 0.45 N·m with included Coaxwave wrench. Run VNA sweep DC–50GHz.

  • Why This Adapter: VSWR ≤1.08:1 and repeatability better than -48dB ensure the adapter contributes <0.05dB measurement uncertainty. At 50GHz, this is the difference between a valid calibration and a calibration error.

Phased-Array T/R Component Test — 2.4mm to 1.85mm

  • Setup: VNA has 2.4mm ports. T/R module test fixture uses 1.85mm connectors. Use CW-24-185-M-F (2.4mm male → 1.85mm female).

  • Workflow: Connect 2.4mm side to VNA. 1.85mm side mates with fixture. Both use M7×0.75 thread — same torque wrench for both ends.

  • Why This Adapter: Seamless mechanical and electrical transition. Shared thread eliminates cross-threading risk. Repeatability <-48dB ensures consistent T/R component characterization.

️ Production ATE — 2.4mm to N-Type Legacy Bridge

  • Setup: New VNA has 2.4mm ports. Production test rack uses N-Type cables (18GHz sufficient). Use CW-24-N-M-M (2.4mm male → N-Type male).

  • Workflow: 2.4mm side torqued to 0.45 N·m with Coaxwave wrench. N-Type side torqued to 1.1 N·m with N-Type wrench. Quick connect/disconnect for production line.

  • Why This Adapter: Bridges precision 2.4mm instrumentation to rugged N-Type infrastructure. Electrically limited to 18GHz — sufficient for many production test applications.

⚠️ Usage Red Lines

  • ⚠️ 2.4mm Torque: 0.45 N·m (4 in-lbs) — Use ONLY the Included Coaxwave Wrench:

    • M7×0.75 metric thread is NOT compatible with SMA/3.5mm/2.92mm wrenches (1/4-36 UNS)

    • A SMA wrench will cross-thread or crack the 2.4mm coupling nut instantly — irreparable damage

    • 1.85mm shares the same M7×0.75 thread — technically compatible, but always use the included Coaxwave wrench for calibration traceability


  • ⚠️ Cross-Series Frequency Is Bounded by the Lower-Grade Interface:

    • 2.4mm ↔ 1.85mm: DC–50GHz (both sides rated to 50GHz)

    • 2.4mm ↔ 2.92mm: limited to 40GHz (2.92mm rating)

    • 2.4mm ↔ 3.5mm / SMA: limited to 26.5GHz

    • 2.4mm ↔ N-Type: limited to 18GHz

    • Know your frequency boundary before selecting the cross-series model


  • ⚠️ Repeatability Requires Proper Torque Every Time:

    • The <-48dB repeatability specification assumes 0.45 N·m torque on every connection

    • Hand-tightening or inconsistent torque will degrade repeatability

    • Always use the included torque wrench — no exceptions


  • ⚠️ Minimum 5-Thread Engagement Required:

    • The M7×0.75 thread requires at least 5 full threads engaged before torque application

    • Hand-start and verify full engagement — never force



Coaxwave 2.4mm Metrology-Grade Adapter · Delivery Commitment

  • Frequency: DC – 50 GHz (same-series)

  • Impedance: 50Ω ±0.5%

  • VSWR: ≤ 1.08:1 (factory, per unit)

  • Insertion Loss: ≤ 0.04√f(GHz) dB (typical, same-series)

  • Repeatability: Better than -48 dB (connection-to-connection at 50GHz)

  • Mating Cycles: ≥ 500

  • Adapter Matrix: 2.4mm same-series + cross-series to 1.85mm/2.92mm/3.5mm/SMA/N-Type = 18 standard models (all M-M/M-F/F-F)

  • Interface: IEEE Std 287™-2007, M7×0.75 thread

  • Materials: Stainless-steel passivated body + BeCu gold-plated center contact + PEI/PTFE dielectric

  • 100% VNA Full-Band S-Parameter Test + CMM Dimensional Verification + Repeatability Verification + Individual Calibration Data Sheet + SN Traceability

  • Included: Coaxwave metrology torque wrench (M7×0.75, 0.45 N·m)

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for 2.4mm Metrology-Grade Selection:

  1. VSWR ≤1.08:1 and Repeatability <-48dB Are Measured Per Unit: Every adapter ships with its own calibration data sheet showing actual S-parameters and repeatability. Your adapter's performance is documented — not estimated from a batch average.

  2. The Included Torque Wrench Is Part of the Specification: The <-48dB repeatability claim assumes 0.45 N·m torque on every connection. Using any other wrench voids the repeatability guarantee. Always use the included Coaxwave torque wrench.

  3. 2.4mm ↔ 1.85mm Is the Only Cross-Series Combination That Reaches 50GHz: All other cross-series options are bounded by the lower-grade interface. For full 50GHz measurements, use same-series 2.4mm ↔ 2.4mm or 2.4mm ↔ 1.85mm adapters.


There is no perfect standard part, only the most suitable solution.

Coaxwave 2.4mm Metrology-Grade Adapters are not merely interconnects; they are the engineered assurance that your VNA calibration reflects the DUT — not the adapter. We control every micron of dimensional variation, verify every S-parameter and repeatability data point with "German precision" and "French engineering logic", and deliver with full SN traceability and a calibrated torque wrench. With eighteen standard models covering every same-series and cross-series need, 100% VNA certification, and a commitment to metrology-grade performance, Coaxwave delivers the most suitable 2.4mm adapter for your exact VNA calibration, 5G/6G, aerospace, and defense requirement.