Coaxwave IP67 NEX10 Adapter is the compact core product of the waterproof industrial series, 50Ω characteristic impedance, DC–6GHz (interface system extendable to 20GHz per structure). Screw-on and push-pull dual coupling versions. Silicone rubber gasket for mated IP67 protection. Operating temperature -55℃ to +125℃. Factory PIM ≤ -160 dBc @ 2×20W. Brass body tri-metal plated, beryllium copper center contact silver-plated, PTFE dielectric. 100% PIM and IP67 spray tested. Covers M-M / M-F / F-F and NEX10 ↔ 4.3-10 / 7/16 DIN / N-Type / SMA cross-series full matrix, straight / 90° / square flange (12.7mm) / bulkhead. Ideal for 5G Small Cell, DAS, outdoor wireless, and industrial RF.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Architecture — Smallest Low-PIM Interface, Now Weatherproof

Attribute

IP67 NEX10 Adapter Specification

Characteristic Impedance

50Ω ±1Ω

Frequency Range

DC–6GHz (interface system extendable to 20GHz per structure)

Coupling Versions

Screw-on (hand-tight threaded) / Push-pull (quick-lock)

Factory PIM (2×20W)

≤ -160 dBc (100% tested)

VSWR (Factory)

≤ 1.25:1

IP Rating

IP67 (mated, silicone rubber gasket)

Operating Temperature

-55℃ ~ +125℃

Power @ 2.6GHz

~80W (sea level, +40℃)

Body Material

Brass, tri-metal plated (standard)

Center Contact

Beryllium copper, silver-plated

Dielectric

PTFE (Teflon®)

Flange Option

Square flange, 12.7 mm flange height

All Transfer Models (every combination across all gender sets and cross-series interfaces):

No.

Model Family

End A

End B

Max Freq

Notes

1

CW-IP67-NEX10-NEX10-MM

NEX10 Male

NEX10 Male

DC–6GHz

In-line barrel

2

CW-IP67-NEX10-NEX10-MF

NEX10 Male

NEX10 Female

DC–6GHz

Standard jumper

3

CW-IP67-NEX10-NEX10-FF

NEX10 Female

NEX10 Female

DC–6GHz

Panel feedthrough

4

CW-IP67-NEX10-4310-MF

NEX10 Male

4.3-10 Female

DC–6GHz

Small Cell to AAS

5

CW-IP67-NEX10-4310-MM

NEX10 Male

4.3-10 Male

DC–6GHz

4.3-10 bridge

6

CW-IP67-NEX10-4310-FF

NEX10 Female

4.3-10 Female

DC–6GHz

Dual-female transition

7

CW-IP67-NEX10-716-MF

NEX10 Male

7/16 DIN Female

DC–6GHz

Small Cell to macro

8

CW-IP67-NEX10-716-MM

NEX10 Male

7/16 DIN Male

DC–6GHz

7/16 barrel bridge

9

CW-IP67-NEX10-716-FF

NEX10 Female

7/16 DIN Female

DC–6GHz

Dual-female 7/16

10

CW-IP67-NEX10-N-MF

NEX10 Male

N-Type Female

DC–6GHz

Compact to standard

11

CW-IP67-NEX10-N-MM

NEX10 Male

N-Type Male

DC–6GHz

N-Type bridge

12

CW-IP67-NEX10-N-FF

NEX10 Female

N-Type Female

DC–6GHz

Panel to N-Type

13

CW-IP67-NEX10-SMA-MF

NEX10 Male

SMA Female

DC–6GHz

Small Cell to test

14

CW-IP67-NEX10-SMA-MM

NEX10 Male

SMA Male

DC–6GHz

SMA barrel bridge

15

CW-IP67-NEX10-SMA-FF

NEX10 Female

SMA Female

DC–6GHz

Test port feedthrough

💡 Every A-to-B combination across NEX10, 4.3-10, 7/16 DIN, N-Type, and SMA is supported. All genders (M/M, M/F, F/F), straight, 90° right-angle, square flange (12.7mm height), and bulkhead configurations available. Every adapter is 100% PIM-tested (2×20W) and IP67 spray-verified before shipment.

Key Performance (Coaxwave IP67 NEX10 specification):

  • PIM (2×20W): ≤ -160 dBc (100% tested, every unit)

  • VSWR: ≤ 1.25:1 across DC–6GHz

  • IP67: Confirmed when properly mated with Coaxwave silicone gaskets

  • Temperature Range: -55℃ ~ +125℃ — widest in the NEX10 portfolio

  • Coupling: Screw-on (hand-tight) or push-pull (tool-free)

Inspection: 100% PIM test (2×20W) + IP67 water spray verification + full-band VSWR test. Each adapter ships with individual serialized labeling and test data.

🎯 Core Positioning: NEX10 Footprint, IP67 Protection, Industrial Temperature Range

The standard NEX10 adapter is specified to +85℃. The IP67 version extends that to +125℃ — a 40℃ margin that matters for enclosed Small Cell radios, industrial RF heaters, and passive DAS nodes mounted inside sealed outdoor cabinets. Combined with the -55℃ cold rating, this adapter covers alpine tower sites and desert deployments alike. The addition of a silicone rubber gasket at the mating plane achieves IP67 when properly coupled — protecting against driving rain, hose-down, and condensation inside weathered enclosures. Two coupling styles give installers the choice between permanent screw-on security and push-pull serviceability.

⚡ Complete Interface Matrix

Same-Series Gender Sets:

  • NEX10 Male to NEX10 Male (CW-IP67-NEX10-NEX10-MM): In-line barrel for extending Small Cell jumper runs without additional cable assemblies.

  • NEX10 Male to NEX10 Female (CW-IP67-NEX10-NEX10-MF): Standard cable-end adapter for radio and antenna interfaces.

  • NEX10 Female to NEX10 Female (CW-IP67-NEX10-NEX10-FF): Panel-mount feedthrough for equipment enclosures and DAS node front panels.

Cross-Series Adapters:

  • NEX10 ↔ 4.3-10: Bridge Small Cell outputs to AAS infrastructure. Both sides hand-tight / push-pull.

  • NEX10 ↔ 7/16 DIN: Interface compact Small Cell to legacy macro antenna. 7/16 DIN side requires 15 N·m torque wrench.

  • NEX10 ↔ N-Type: Connect Small Cell to standard N-Type antenna ports. N-Type side requires 1.1 N·m torque wrench.

  • NEX10 ↔ SMA: Adapt Small Cell test ports to laboratory VNA and signal analyzers. SMA side requires 0.9 N·m torque wrench.

Mounting Configurations:

  • Straight: Standard inline and cable-mount.

  • 90° Right-Angle: For enclosures where panel clearance is under 10 mm.

  • Square Flange: 12.7 mm flange height, 4-hole mount for secure panel penetration in industrial enclosures.

  • Bulkhead: Rear-mount for weather-sealed enclosure entry.

🛡️ Coaxwave Quality Barrier

Every IP67 NEX10 Adapter undergoes three mandatory 100% controls:

  1. 100% PIM Test (2×20W Dual-Carrier): Per IEC 62037. Both carriers at +43 dBm (20W each). PIM ≤ -160 dBc recorded for each unit.

  2. 100% IP67 Spray Verification: Each adapter fitted with silicone gasket is spray-tested per IEC 60529 IP67 requirements when mated with a qualified counterpart.

  3. 100% Full-Band VSWR Test: Swept from DC to 6GHz. VSWR ≤ 1.25:1 verified.


Electrical Performance

  • Characteristic Impedance: 50Ω ±1Ω

  • Frequency Range: DC–6GHz (interface system extendable to 20GHz per structure)

  • VSWR: ≤ 1.25:1

  • PIM (2×20W): ≤ -160 dBc (100% tested)

  • Dielectric Withstanding Voltage: ≥ 1000V RMS

  • Insulation Resistance: ≥ 5000 MΩ

  • Contact Resistance: Center ≤ 1.5 mΩ; Outer ≤ 1.0 mΩ

  • Power Handling: ~80W @ 2.6GHz (sea level, +40℃)

Mechanical Performance

  • Coupling Versions: Screw-on (hand-tight threaded) / Push-pull (quick-lock, tool-free)

  • Mating Cycles: ≥ 500 (proper engagement)

  • Retention Force: Axial pull-off ≥ 180 N (mated)

  • Flange Option: Square flange, 12.7 mm height, 4-hole

  • Mounting Options: Straight, 90° right-angle, square flange, bulkhead

Materials & Structure

  • Body / Shell: Brass, tri-metal plated (standard); stainless steel (marine/industrial, on request)

  • Center Contact: Beryllium copper, silver-plated

  • Dielectric Support: PTFE (Teflon®), precision-machined

  • Gasket / O-Ring: Silicone rubber, weather-resistant (IP67)

  • Lock Nut (Screw-On): Brass, tri-metal plated

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃ (widest range in the NEX10 portfolio)

  • Storage Temperature: -65℃ ~ +135℃

  • Water Ingress: IP67 when properly mated with Coaxwave silicone gaskets

  • Salt-Spray Resistance: ≥ 96 hours (tri-metal); ≥ 200 hours (stainless steel)

  • UV Resistance: Excellent — materials selected for >20-year outdoor exposure

  • RoHS / REACH: Compliant (silver plating exemption per Annex III, 6(c))

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • Screw-On — Hand-Tight Only: Finger-tight until snug. No torque wrench required. Over-tightening risks cracking the PTFE dielectric.

  • Push-Pull Operation: Align bayonet grooves, push to engage until click, pull sleeve to disengage. No rotation needed — ideal for blind-mate in dense enclosures.

  • Cross-Series Torque Requirements:

    • 7/16 DIN side: 15 N·m — dedicated 7/16 DIN torque wrench required

    • N-Type side: 1.1 N·m — N-Type torque wrench required

    • SMA side: 0.9 N·m — SMA torque wrench required


  • Weather Sealing: For outdoor installations, use Coaxwave self-amalgamating tape + weather boots at the mated junction. The silicone gasket provides IP67 at the interface plane.

  • ⚠️ Temperature Derating Above +85℃: At +125℃, power handling derates to approximately 40W @ 2.6GHz due to thermal limits of the PTFE dielectric. Consult Coaxwave for high-temperature power budgets.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

5G Small Cell

CW-IP67-NEX10-NEX10-MF

IP67, hand-tight

Radio to antenna

DAS Remote Node

CW-IP67-NEX10-4310-MF

Push-pull serviceable

Node to distributed antenna

Industrial RF Enclosure

CW-IP67-NEX10-NEX10-FF (Flange)

Square flange 12.7mm, +125℃

Factory floor radio

Macro BTS Retrofit

CW-IP67-NEX10-716-MF

Compact to 7/16 DIN

Legacy tower upgrade

Standard Antenna Feed

CW-IP67-NEX10-N-MF

NEX10 to N-Type

Small Cell to existing antenna

Production Test

CW-IP67-NEX10-SMA-MF

Small Cell to VNA

End-of-line verification

Dense Enclosure

CW-IP67-NEX10-NEX10-MF (RA)

90° right-angle

< 10mm clearance

Sealed Cabinet

CW-IP67-NEX10-NEX10-MF (PP)

Push-pull, IP67

Enclosed DAS node

Alpine Tower

CW-IP67-NEX10-NEX10-MM

-55℃ rated

High-altitude site

Desert Deployment

CW-IP67-NEX10-4310-MF

+125℃ rated

Extreme heat environment

Standard Matrix & Extensions

  • Gender Sets: M-M, M-F, F-F in NEX10 (IP67 gasket on all mated faces)

  • Cross-Series Adapters: NEX10 ↔ 4.3-10 / 7/16 DIN / N-Type / SMA (all genders)

  • Coupling Versions: Screw-on (hand-tight) / Push-pull (quick-lock)

  • Mounting Styles: Straight, 90° right-angle, square flange (12.7mm), bulkhead

  • Full Kit: Adapter + silicone gaskets + weather boots + protective caps + serialized PIM test data

⚡ Electrical Performance Customization

  • Ultra-Low PIM Option: ≤ -166 dBc (special order, extended test time, individual certification)

  • Phase-Matched Sets: Multiple adapters matched for MIMO diversity arrays

  • Extended Frequency: Interface system extendable to 20GHz per structural configuration — consult Coaxwave for 12–20GHz builds

Structural Customization

  • Right-Angle Variants: 90° for enclosures with < 10mm panel clearance

  • Square Flange: 12.7mm flange height, 4-hole for industrial panel penetration

  • Push-Pull Quick-Lock: Tool-free blind-mate for high-density DAS remote nodes

️ Material & Environmental Customization

  • Stainless Steel Body: Passivated for coastal and industrial chemical environments (≥ 200 hr salt-spray)

  • Non-Magnetic Version: Beryllium copper body with gold plating for EMC chambers (special order)

  • High-Temp Gasket: Fluorosilicone for continuous operation above +125℃ (consult Coaxwave)

Service & Support

  • 100% PIM + IP67 + VSWR Test: Every adapter verified before shipment

  • Serialized Traceability: Laser-marked serial numbers on adapter bodies

  • Rapid Prototyping: Standard 3–5 days; custom 1–2 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • Coupling version selection (screw-on vs. push-pull) based on service frequency and security needs

    • PIM budget analysis for multi-carrier Small Cell deployments

    • Thermal derating guidance for +85℃ to +125℃ operating range

    • Link-budget and power-handling calculations


Tip

"There is no perfect standard part, only the most suitable solution."

5G Small Cell — IP67 NEX10 Screw-On, Straight

  • Setup: Urban Small Cell, 4×4 MIMO, 8W per carrier. NEX10 interfaces on both radio and antenna. Use CW-IP67-NEX10-NEX10-MF (screw-on, tri-metal, straight).

  • Workflow: NEX10 male hand-tightened to radio output. Female to antenna port. Silicone gasket compresses for IP67 seal. Self-amalgamating tape + weather boot over junction. No torque wrench needed.

  • Why This Adapter: IP67 protection for outdoor Small Cell. PIM ≤ -160 dBc ensures clean multi-carrier operation. Hand-tight screw-on coupling. Operating range -55℃ to +125℃ covers extreme climates.

DAS Remote Node — IP67 NEX10 Push-Pull to 4.3-10

  • Setup: Office building DAS, remote node in ceiling-mounted sealed enclosure. Node output feeds 4.3-10 distributed antenna. Use CW-IP67-NEX10-4310-MF (push-pull on NEX10 side).

  • Workflow: NEX10 push-pull engaged on remote node (align, push, click). 4.3-10 female hand-tight on antenna. IP67 gasket seals node side.

  • Why This Adapter: Push-pull enables tool-free servicing without opening the sealed enclosure. 4.3-10 side interfaces to existing AAS antenna infrastructure. IP67 protects against ceiling condensation and dust.

Industrial RF Cabinet — Square Flange, +125℃

  • Setup: Factory floor, sealed RF cabinet with internal temperature reaching +110℃. Use CW-IP67-NEX10-NEX10-FF (square flange, 12.7mm height, screw-on).

  • Workflow: Adapter mounted to cabinet wall via 4-hole square flange. NEX10 male on internal radio hand-tight to flange female. External antenna cable hand-tight to flange male outside. Silicone gasket seals panel penetration.

  • Why This Adapter: Square flange provides secure 12.7mm panel penetration. +125℃ rating handles cabinet heat. IP67 prevents dust and moisture ingress into sealed cabinet. PIM ≤ -160 dBc for clean industrial RF transmission.

⚠️ Usage Red Lines

  • ⚠️ Screw-On Is Hand-Tight — Do Not Use a Wrench:

    • Threaded coupling is designed for finger-tight only. A wrench can crack the PTFE dielectric or strip the brass threads

    • Hand-tight delivers the specified PIM and IP67 seal. A wrench adds risk with no benefit


  • ⚠️ Push-Pull Requires Visual Alignment:

    • Push-pull bayonet grooves must be aligned before engagement. Forcing a misaligned push-pull causes permanent mechanical damage

    • Listen for the click. If there is no click, the adapter is not locked


  • ⚠️ Cross-Series Torque Still Applies:

    • The NEX10 side is hand-tight. The 7/16 DIN, N-Type, or SMA side still requires proper torque

    • 7/16 DIN: 15 N·m. N-Type: 1.1 N·m. SMA: 0.9 N·m


  • ⚠️ Power Derating Above +85℃:

    • At +125℃, power handling drops to ~40W @ 2.6GHz. For high-power applications in hot enclosures, consult Coaxwave for thermal analysis

    • Do not assume room-temperature power ratings apply at +125℃



Coaxwave IP67 NEX10 Adapter · Delivery Commitment

  • Impedance: 50Ω ±1Ω

  • Frequency Range: DC–6GHz (extendable to 20GHz per structure)

  • PIM (2×20W): ≤ -160 dBc (100% tested)

  • VSWR: ≤ 1.25:1

  • IP Rating: IP67 (mated, silicone gasket)

  • Temperature Range: -55℃ ~ +125℃ (widest in NEX10 portfolio)

  • Coupling: Screw-on (hand-tight) / Push-pull (tool-free)

  • Flange Option: Square flange, 12.7 mm height

  • Adapter Matrix: NEX10 ↔ NEX10 / 4.3-10 / 7/16 DIN / N-Type / SMA — any A-to-B, all genders

  • 100% PIM + IP67 Spray Test + VSWR Test + Serialized Traceability

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for IP67 NEX10 Selection:

  1. -55℃ to +125℃ — The Widest Temperature Range in the Portfolio: When your deployment spans alpine to desert, or sealed industrial cabinets, this is the only NEX10 adapter rated for the full extreme.

  2. Screw-On vs Push-Pull — Choose by Service Model: Screw-on for permanent outdoor installations. Push-pull for DAS nodes that field technicians access regularly.

  3. IP67 Requires the Gasket: The silicone gasket is what makes this adapter IP67. If the gasket is damaged or missing, the IP67 rating is void. Always inspect the gasket before installation.


There is no perfect standard part, only the most suitable solution.

Coaxwave IP67 NEX10 Adapters are engineered interconnects where tri-metal durability, beryllium-copper-silver signal integrity, and silicone-gasket IP67 protection deliver the most compact, weatherproof, low-PIM 50Ω interface for 5G Small Cell, DAS, and industrial RF. Every adapter is PIM-tested with 2×20W dual-carrier, IP67 spray-verified, and VSWR-certified with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning 4.3-10, 7/16 DIN, N-Type, and SMA, Coaxwave delivers the most suitable IP67 NEX10 solution for your exact Small Cell, DAS, and outdoor wireless requirement.