Coaxwave HN Adapters are precision-engineered high-voltage, high-power RF interconnects for applications where standard N-Type or SMA interfaces cannot safely handle the voltage and power levels. The HN interface was originally developed for military airborne radar and high-power broadcast transmitters — environments demanding 5000 V RMS dielectric withstanding voltage and 1200W continuous power at 1GHz. Coaxwave HN Adapters maintain full compliance with IEC 60169-2 and MIL-STD-348 interface dimensions while optimizing internal geometry for uniform electric field distribution. The captivated center contact design prevents accidental disengagement under high-vibration conditions. Every unit is 100% RF-tested and high-potential (hipot) verified before shipment.
Architecture — 5000V Dielectric Strength, 1200W Power Handling
Attribute | HN Adapter Specification |
|---|---|
Characteristic Impedance | 50Ω ±2Ω |
Frequency Range | DC–3GHz (standard); DC–4GHz (extended on select structures) |
Dielectric Withstanding Voltage | 5000 V RMS min. (at sea level, 60Hz, 1 minute) |
Continuous Working Voltage | 1500 V RMS (sea level, 25℃) |
Rated Power | 1200W @ 1GHz (sea level, 25℃); derates with altitude and temperature |
VSWR (Factory) | ≤ 1.20:1 (DC–2GHz); ≤ 1.30:1 (2–4GHz) |
Insertion Loss | ≤ 0.03 × √f(GHz) dB (typical, per mated pair) |
Body Material | Brass, nickel-plated or tri-metal plated |
Center Contact | Beryllium copper (C17510), gold-plated |
Dielectric | Virgin PTFE (Teflon®), low-loss |
Contact Design | Captivated center contact — prevents pull-out under vibration |
Coupling | Threaded 3/4-20 UNEF, 5/8-24 UNEF variants |
All Transfer Models (every combination across all gender sets and cross-series interfaces):
No. | Model Family | End A | End B | Max Freq | Notes |
|---|---|---|---|---|---|
1 | CW-HN-HN-MM | HN Male | HN Male | DC–4GHz | In-line barrel, high-voltage |
2 | CW-HN-HN-MF | HN Male | HN Female | DC–4GHz | Standard jumper |
3 | CW-HN-HN-FF | HN Female | HN Female | DC–4GHz | Panel feedthrough |
4 | CW-HN-HN-FM | HN Female | HN Male | DC–4GHz | Reverse-gender jumper |
5 | CW-HN-N-MM | HN Male | N-Type Male | DC–3GHz | HN-to-N high-power bridge |
6 | CW-HN-N-MF | HN Male | N-Type Female | DC–3GHz | N-Type antenna feed |
7 | CW-HN-N-FF | HN Female | N-Type Female | DC–3GHz | N-Type panel |
8 | CW-HN-N-FM | HN Female | N-Type Male | DC–3GHz | Reverse N-bridge |
9 | CW-HN-SMA-MM | HN Male | SMA Male | DC–3GHz | HN-to-SMA transition |
10 | CW-HN-SMA-MF | HN Male | SMA Female | DC–3GHz | SMA test port |
11 | CW-HN-SMA-FF | HN Female | SMA Female | DC–3GHz | SMA panel |
12 | CW-HN-SMA-FM | HN Female | SMA Male | DC–3GHz | Reverse SMA bridge |
💡 Every A-to-B combination across HN (M-M, M-F, F-F, F-M) and N-Type / SMA (all genders) is supported. Straight, 90° right-angle, flange-mount, bulkhead, and T-adapter configurations available. Every adapter is 100% hipot-tested at 5000 V RMS and RF-verified before shipment.
Key Performance (Coaxwave HN specification):
Dielectric Withstanding Voltage: 5000 V RMS min. (MIL-STD-348 Method 301)
Rated Power: 1200W @ 1GHz — derates to 600W @ 2GHz, 300W @ 3GHz
Captivated Contact: Center conductor mechanically retained — cannot be pulled out during mating/unmating
Compliance: IEC 60169-2 interface dimensions, MIL-STD-348 compatibility
Standard N-Type connectors are rated for 1000 V RMS dielectric withstanding and ~500W at 1GHz. SMA connectors are limited to 500 V RMS and ~100W. When your application involves high-voltage RF test benches, airborne radar transmitters, or radiation detection systems operating above these thresholds, the HN interface is the only safe choice. Coaxwave HN Adapters feature extended air gaps in the dielectric path, reinforced PTFE standoffs, and captivated center contacts that maintain precise 50Ω geometry while withstanding 5000 V RMS without flashover. The larger shell diameter (compared to N-Type) provides superior corona suppression at altitude.
Same-Series Gender Sets:
HN Male to HN Male (CW-HN-HN-MM): In-line barrel for extending high-voltage RF lines in test benches and transmitter chains.
HN Male to HN Female (CW-HN-HN-MF): Standard cable-end adapter for high-power amplifier outputs and antenna feeds.
HN Female to HN Female (CW-HN-HN-FF): Panel-mount feedthrough for sealed enclosures and high-voltage equipment racks.
HN Female to HN Male (CW-HN-HN-FM): Reverse-gender jumper for legacy equipment with non-standard port orientations.
Cross-Series Adapters:
HN ↔ N-Type: Most common bridge — connect HN high-voltage infrastructure to standard N-Type 11GHz test equipment. N-Type side limited to 1000 V RMS (use caution when stepping up voltage).
HN ↔ SMA: Adapt HN high-power lines to SMA ground-test ports. SMA side limited to 500 V RMS — for low-voltage test access only.
Mounting Configurations:
Straight Cable: Standard solder termination for RG-213, LMR-400, and other large-diameter coaxial cables.
90° Right-Angle: For enclosures where cable exit direction must be controlled in dense rack installations.
Flange Mount: 4-hole panel penetration for secure mounting in high-vibration environments (airborne, shipboard).
Bulkhead: Front/rear panel feedthrough for weather-sealed outdoor enclosures.
T-Adapter: 3-port HN splitter for power divider applications in radar and broadcast transmitters.
Every HN Adapter undergoes four mandatory 100% controls:
5000 V RMS Hipot Test: Per-unit dielectric withstanding verification at 60Hz, 1 minute. No breakdown or corona.
100% VNA RF Test: Swept from 10 MHz to 3GHz (or 4GHz extended). S11, S21 recorded. VSWR and insertion loss verified.
Contact Retention Test: Axial pull-off force verified on captivated center contact — minimum 100 N.
Plating Thickness Verification: XRF measurement of nickel (≥ 2.5 μm) and gold (≥ 0.5 μm) plating layers.
Characteristic Impedance: 50Ω ±2Ω
Frequency Range: DC–3GHz (standard); DC–4GHz (extended select structures)
VSWR: ≤ 1.20:1 (DC–2GHz); ≤ 1.30:1 (2–4GHz)
Insertion Loss: ≤ 0.03 × √f(GHz) dB (typical, per mated pair)
Dielectric Withstanding Voltage: 5000 V RMS min. (60Hz, 1 min, sea level)
Continuous Working Voltage: 1500 V RMS (sea level, 25℃)
Rated Power: 1200W @ 1GHz; 600W @ 2GHz; 300W @ 3GHz (sea level, 25℃)
Insulation Resistance: ≥ 5000 MΩ (at 500 V DC)
Coupling Mechanism: Threaded 3/4-20 UNEF (standard HN); 5/8-24 UNEF (variant)
Recommended Torque: 3.4–4.5 N·m (25–40 in-lb) for 3/4-20 UNEF
Mating Cycles: ≥ 500 (clean environment, proper torque)
Center Contact Retention: Captivated design — axial pull-off ≥ 100 N
Cable Retention: ≥ 200 N axial (properly crimped/soldered)
Mounting Options: Straight cable, 90° right-angle, 4-hole flange, bulkhead, T-adapter
Body / Shell: Brass, nickel-plated (≥ 2.5 μm) or tri-metal plated (Sn-Ni-Cu)
Center Contact: Beryllium copper (C17510), gold-plated (≥ 0.5 μm)
Dielectric: Virgin PTFE (Teflon®), precision-machined standoffs
Captivated Mechanism: Spring-loaded ball-lock or crimp-retained center contact — prevents accidental disengagement
Operating Temperature: -55℃ ~ +85℃ (standard); up to +125℃ with derated power
Altitude: Sea level to 15,000 m (corona suppression design for high-altitude operation)
Humidity: 95% RH non-condensing (with proper sealing gaskets)
Vibration: MIL-STD-202 Method 204, Condition D (20G, 5–2000 Hz)
Shock: MIL-STD-202 Method 213, Condition I (100G, 6 ms)
Compliance: IEC 60169-2 interface dimensions, MIL-STD-348 compatibility
RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))
3/4-20 UNEF Thread — 3.4–4.5 N·m: Use a properly calibrated torque wrench. Under-tightening causes intermittent contact and arcing at high voltage. Over-tightening galls threads.
Corona Suppression at Altitude: The HN shell diameter is intentionally larger than N-Type to suppress corona discharge at reduced atmospheric pressure. Do not substitute with N-Type in unpressurized airborne or space-simulated environments.
Power Derating Is Mandatory: 1200W @ 1GHz is specified at sea level, 25℃. At 3000 m altitude, derate to 70%. At 15,000 m, derate to 40%. Above 3GHz, power rating drops proportionally with frequency.
⚠️ Cross-Series Voltage Limit: When using HN↔N or HN↔SMA adapters, the lower-voltage interface (N: 1000V, SMA: 500V) becomes the system limit. Never apply 1500V RMS to the N or SMA side.
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
High-Voltage RF Test Bench | CW-HN-HN-MF (Ni) | 5000V hipot verified | 3000V RF burn-in test |
Airborne Radar Transmitter | CW-HN-HN-FL (Tri-metal) | 1200W, 4.5 N·m torque | Fighter jet fire-control radar |
Radiation Detection System | CW-HN-HN-FF (Bulkhead) | Hermetic option, HV feedthrough | Gamma-ray detector bias |
Outdoor Base Station | CW-HN-N-MF (Tri-metal) | Weather-sealed, 1500V | High-power macro cell TX |
Broadcast Transmitter | CW-HN-HN-T (Flange) | T-adapter, 1200W split | UHF TV transmitter combiner |
Shipboard Radar | CW-HN-SMA-MF (Ni) | Salt-spray resistant | Naval surface-search radar |
Particle Accelerator RF | CW-HN-HN-MM (Ni) | 5000V, low PIM | Klystron driver line |
Medical MRI Gradient | CW-HN-HN-MF (Tri-metal) | High-voltage, low EMI | Gradient coil drive |
Gender Sets: M-M, M-F, F-F, F-M in HN (all high-voltage rated)
Cross-Series Adapters: HN ↔ N-Type / SMA (all genders, F-M reverse included)
Mounting Styles: Straight, 90° right-angle, 4-hole flange, bulkhead, T-adapter
Full Kit: Adapter + torque wrench + protective caps + serialized test report
Extended Frequency (DC–4GHz): Select structures validated to 4GHz for S-band radar applications
High-Voltage Screening: Optional 7500 V RMS hipot test (150% of standard) for critical aerospace programs
Low-PIM Option: Optimized contact geometry for PIM ≤ -160 dBc (passive intermodulation sensitive systems)
Hermetic Version: Glass-sealed feedthrough for pressurized high-voltage enclosures (consult Coaxwave)
Captivated Contact Variants: Spring-ball lock (tool-free) or crimp-retained (permanent) — select based on serviceability requirements
Right-Angle Variants: 90° for constrained rack-mount or airborne equipment bays
Tri-Metal Plating: Sn-Ni-Cu stack for superior salt-spray and humidity resistance (naval/shipboard)
Heavy Gold Plating: Thick gold on center contact for maximum mating-cycle life in test laboratories
Stainless Steel Body: For corrosive environments (chemical plants, offshore platforms) — special order
100% Hipot Test Certificate: Every adapter ships with 5000 V RMS test data and operator sign-off
Serialized Traceability: Laser-marked serial numbers on adapter bodies
Rapid Prototyping: Standard 2–3 weeks; custom 4–6 weeks (hermetic or special plating)
Application Engineering: Coaxwave RF engineers provide:
Power derating calculations based on altitude, temperature, and duty cycle
Voltage step-up/step-down guidance for cross-series adapter installations
Corona inception voltage analysis for high-altitude and space-simulated environments
PIM budgeting for multi-channel high-power transmitter combiners
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: Automated RF burn-in chamber, 3000 V RMS test voltage, 1000W forward power at 1GHz. Use CW-HN-HN-MF (brass nickel, straight).
Workflow: HN female receptacles on test fixture. Male plug on RG-213 cable hand-tight (4.0 N·m torque wrench). 5000 V hipot pre-test passed. Chamber energized — 3000V, 1000W for 24 hours. No breakdown, no excessive heating.
Why This Adapter: 5000 V RMS dielectric rating provides 1.67× safety margin over 3000V operating. Captivated center contact prevents arc-flash from contact separation. Brass nickel plating withstands repeated thermal cycling.
Setup: Fighter jet radar transmitter, 1200W peak at 9.5 GHz. Extreme vibration (20G random) and altitude (15,000 m). Use CW-HN-HN-FL (tri-metal, 4-hole flange, extended 4GHz).
Workflow: Adapter flange-mounted on transmitter enclosure wall. HN male on internal high-power cable torqued to 4.5 N·m. Aircraft executes maneuvers — 20G vibration, no discontinuity. Altitude 15,000 m — no corona.
Why This Adapter: 1200W rated at 1GHz (derated to ~130W at 9.5GHz, within safe margin). Tri-metal plating resists salt-spray and humidity. 4-hole flange prevents torque loosening under vibration. Extended 4GHz structure supports S-band harmonics.
Setup: Macro cell base station, TX power 400W @ 2.1 GHz. Lightning surge protection requires 1500V continuous working voltage rating on RF feed. Use CW-HN-N-MF (tri-metal, weather-sealed bulkhead).
Workflow: HN male on surge protector output. N-Type female connects to antenna feedline. System installed on tower — exposed to rain, UV, temperature cycling (-30℃ to +60℃). Five years of continuous service.
Why This Adapter: 1500V continuous working voltage matches surge protector rating. Tri-metal plating prevents galvanic corrosion between dissimilar metals in outdoor environment. Weather-sealed bulkhead prevents moisture ingress.
⚠️ 5000 V RMS IS LETHAL — TRAINED PERSONNEL ONLY:
The dielectric withstanding voltage of 5000 V RMS can be fatal upon contact
Only qualified high-voltage technicians may handle energized HN connections. Always discharge capacitors and verify zero-energy state before mating/unmating
⚠️ Cross-Series Voltage Is Limited by the Lower-Rated Interface:
HN↔N adapter: N-Type side limited to 1000 V RMS maximum
HN↔SMA adapter: SMA side limited to 500 V RMS maximum
Never apply HN-rated voltage (1500V+) to the N or SMA side. System voltage must not exceed the lowest-rated interface in the chain
⚠️ Power Derating Is Not Optional:
1200W @ 1GHz is sea-level, 25℃ specification. At 3GHz, rating drops to 300W. At 15,000 m altitude, rating drops to 40%
Always calculate derated power for your specific altitude, temperature, and frequency. Over-power causes PTFE outgassing, carbon tracking, and catastrophic flashover
⚠️ Torque Specification Is Critical:
3/4-20 UNEF requires 3.4–4.5 N·m. Under-torque → intermittent contact → arcing → fire. Over-torque → thread galling → permanent damage
Use ONLY a calibrated torque wrench. Never finger-tighten high-voltage RF connections
Impedance: 50Ω ±2Ω
Frequency Range: DC–3GHz (standard); DC–4GHz (extended)
Dielectric Withstanding Voltage: 5000 V RMS min. (100% hipot tested per unit)
Continuous Working Voltage: 1500 V RMS (sea level, 25℃)
Rated Power: 1200W @ 1GHz (derates with frequency, altitude, temperature)
Body Options: Brass nickel-plated / Brass tri-metal plated
Center Contact: Beryllium copper, gold-plated
Adapter Matrix: HN ↔ HN / N-Type / SMA — any A-to-B, all genders (M-M, M-F, F-F, F-M)
100% 5000V Hipot Test + VNA S-Parameters + Serialized Traceability
Compliance: IEC 60169-2, MIL-STD-348 | sales@coaxial-rf.com
⚠️ Three Reminders for HN Adapter Selection:
HN Is the Only Safe Choice Above 1000 V RMS: If your system operates above N-Type voltage limits, do not "make do" with N-Type. The HN interface exists specifically for 1500V continuous / 5000V withstand. Use it.
Captivated Contact Prevents Arc-Flash: In high-vibration environments, a loose center contact at 1500V RMS will arc internally, destroying the adapter and potentially the connected equipment. The captivated design is not optional — it is a safety feature.
Power Derating Must Be Calculated Before Deployment: The 1200W rating is a sea-level, 25℃, 1GHz specification. Every real-world deployment requires derating. Coaxwave application engineers will calculate the exact safe power limit for your environment — request this service before finalizing your design.
There is no perfect standard part, only the most suitable solution.
Coaxwave HN Adapters are engineered interconnects where extended air-gap dielectric design, captivated center contacts, and precision-machined PTFE standoffs deliver the most trusted 5000V/1200W RF interface for high-voltage test benches, airborne radar, radiation detection, and outdoor base stations. Every adapter is hipot-tested, RF-verified, and built with "German precision" and "French engineering logic", and ships with full serialized traceability. With cross-series adapters spanning N-Type and SMA, Coaxwave delivers the most suitable high-voltage HN solution for your exact power and voltage requirement.
Sales Email: sales@coaxial-rf.com
Company Website: