Coaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-TraceableCoaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-Traceable
  • Coaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-Traceable
  • Coaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-Traceable
  • 1/2
  • Coaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-Traceable
  • Coaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-Traceable

Coaxwave BNC Male PCB Connector 50Ω/75Ω DC-4GHz Bayonet | SN-Traceable

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave BNC male PCB-mount connectors feature a dual-bayonet lock, dual 50Ω/75Ω impedance per IEC 61169-8, MIL-PRF-39012, CECC 22120. 50Ω: DC–4GHz (std) / DC–10GHz (precision). 75Ω: DC–1GHz (std) / DC–4GHz (broadcast SDI). Through-hole, RA, panel, 4-hole flange. Brass nickel, BeCu/phosphor bronze gold (≥1.27μm), PTFE. SN-laser-marked; VNA data at s2p.coax-rf.cn. Built to "German precision, French engineering logic."
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave BNC male PCB-mount connectors are the definitive dual-bayonet 50Ω/75Ω RF and video interfaces, engineered for oscilloscopes, signal generators, security DVRs, SDI broadcast equipment, and medical test instruments. The platform supports 50Ω RF versions (DC–4GHz standard / DC–10GHz precision) and 75Ω video versions (DC–1GHz standard / DC–4GHz broadcast-grade SDI/HD-SDI), all in a single, mechanically interchangeable bayonet form factor. Four board-mount configurations — through-hole straight, right-angle, panel mount, and 4-hole flange — provide complete layout flexibility for front-panel I/O and internal PCB interconnects.

The product line covers 15 standard models across PCB-mount male plugs, same-series adapters, and cross-series transitions:

No.

Model Family

Configuration

Frequency

Notes

1

CW-BNC-M-TH

BNC Plug, Through-Hole

DC–4GHz (50Ω) / DC–10GHz (50Ω Precision)

PCB vertical mount

2

CW-BNC-M-RA

BNC Plug, Right-Angle

DC–4GHz (50Ω) / DC–10GHz (50Ω Precision)

90° low-profile routing

3

CW-BNC-M-PNL

BNC Plug, Panel Mount

DC–4GHz (50Ω) / DC–10GHz (50Ω Precision)

Chassis front panel

4

CW-BNC-M-4HF

BNC Plug, 4-Hole Flange

DC–4GHz (50Ω) / DC–10GHz (50Ω Precision)

High-stability panel

5

CW-BNC-MM

BNC M ↔ M Barrel

DC–4GHz (50Ω) / DC–1GHz (75Ω)

In-line gender bridge

6

CW-BNC-FF

BNC F ↔ F Barrel

DC–4GHz (50Ω) / DC–1GHz (75Ω)

In-line coupler

7

CW-BNC-MF

BNC M ↔ F Adapter

DC–4GHz (50Ω) / DC–1GHz (75Ω)

Gender adapter

8

CW-BNC-SMA-MF

BNC to SMA M-F

DC–4GHz*

50Ω test bridge

9

CW-BNC-TNC-MF

BNC to TNC M-F

DC–4GHz*

Vibration-proof bridge

10

CW-BNC-N-MF

BNC to N-Type M-F

DC–4GHz*

High-power bridge

11

CW-BNC-UHF-MF

BNC to UHF M-F

DC–300MHz**

Legacy radio bridge

12

CW-BNC-SMB-MF

BNC to SMB M-F

DC–4GHz*

Sub-miniature bridge

13

CW-BNC-HDBNC-MF

BNC to HD BNC M-F

DC–4GHz*

High-density bridge

14

CW-BNC-FTYPE-MF

BNC to F-Type M-F

DC–1GHz***

75Ω CATV bridge

15

CW-BNC-RCA-MF

BNC to RCA M-F

DC–1GHz***

Analog video bridge

* Bandwidth limited to 4GHz by BNC side.    ** Bandwidth limited to 300MHz by UHF side.    *** Bandwidth depends on 75Ω version (DC–1GHz standard / DC–4GHz broadcast).

💡 Every model is 100% VNA-tested from 10 MHz to its rated upper frequency, laser-marked with a unique serial number. Login to s2p.coax-rf.cn with SN + 8-digit code to download the factory Touchstone (.s2p) file.

Key Performance (Coaxwave BNC Male PCB Series specification):

  • Impedance: 50Ω ±2Ω (RF) / 75Ω ±2Ω (video)

  • Frequency Range: 50Ω: DC–4GHz (std) / DC–10GHz (precision); 75Ω: DC–1GHz (std) / DC–4GHz (broadcast)

  • Return Loss: ≥ 20dB (typical, 50Ω std @ ≤2GHz)

  • Insertion Loss: ≤ 0.1 × √f(GHz) dB (50Ω std)

  • Durability: ≥ 500 mating cycles

🎯 Core Positioning: The Dual-Impedance Bayonet Standard for Test & Broadcast

The BNC connector is the most recognized and widely deployed RF interface in electronic test and broadcast, offering a push-and-1/4-turn dual-bayonet coupling that provides positive mechanical confirmation without tools. Coaxwave BNC male PCB-mount series brings German precision manufacturing to this timeless interface. The platform supports dual impedance systems — 50Ω for RF instrumentation (with an optional DC–10GHz precision version) and 75Ω for SDI/HD-SDI broadcast video — in identical mechanical envelopes. This allows designers to standardize on a single panel cutout while supporting both impedance domains.

⚡ Complete 15-Model Interface Matrix

① PCB-Mount Male Plugs — 4 Board Integration Variants

  • Through-Hole Straight (DC–4GHz / DC–10GHz): Vertical PCB insertion with robust mechanical retention. Preferred for serviceable test equipment front panels and security DVR motherboards subjected to frequent patching.

  • Right-Angle (DC–4GHz / DC–10GHz): 90° exit routes the coaxial path parallel to the PCB surface. Critical for slim-profile medical instruments and space-constrained signal generator backplanes.

  • Panel Mount (DC–4GHz / DC–10GHz): Chassis front-panel receptacle with hex nut. Enables direct connection of BNC-jack-terminated cables to the equipment face.

  • 4-Hole Flange (DC–4GHz / DC–10GHz): Maximum vibration resistance for airborne, vehicular, and high-G environments. Secured with four M2.5 or #4-40 screws.

② Same-Series Adapters (3 Models)

  • BNC M ↔ M Barrel (DC–4GHz): In-line gender bridge for joining two BNC-jack-terminated cables. Common in mobile test harness extensions.

  • BNC F ↔ F Barrel (DC–4GHz): In-line coupler for extending two BNC-plug-terminated cables. Essential for long video cable runs in studio installations.

  • BNC M ↔ F Adapter (DC–4GHz): Converts a jack port to accept a plug — or vice versa. Used for port gender correction on patch panels.

③ Cross-Series Adapters (8 Models)

  • BNC to SMA M-F (DC–4GHz*): Bridges BNC equipment to SMA-portable test gear (VNA, spectrum analyzer). The most common lab adapter.

  • BNC to TNC M-F (DC–4GHz*): Threaded alternative for vibration-prone mobile test setups where BNC bayonet may loosen.

  • BNC to N-Type M-F (DC–4GHz*): Links BNC test setups to N-Type high-power amplifiers.

  • BNC to UHF M-F (DC–300MHz**): Connects BNC test gear to legacy UHF/PL-259 field radios (bandwidth limited to 300MHz).

  • BNC to SMB M-F (DC–4GHz*): Sub-miniature bridge for connecting BNC infrastructure to SMB-port modules.

  • BNC to HD BNC M-F (DC–4GHz*): Adapts standard BNC ports to HD BNC high-density interfaces for hybrid bay installations.

  • BNC to F-Type M-F (DC–1GHz***): 75Ω CATV bridge for connecting BNC video equipment to F-Type consumer video distribution.

  • BNC to RCA M-F (DC–1GHz***): Analog composite video bridge for interfacing BNC professional monitors to RCA consumer sources.

🛡️ Coaxwave Quality Barrier — SN Traceability & Touchstone Delivery

Every BNC connector and adapter undergoes four mandatory 100% controls:

  1. 100% VNA Full-Band S-Parameter Test: Swept from 10 MHz to 4GHz (50Ω) or 10GHz (precision). S11, S21 recorded. Return loss and VSWR verified.

  2. Touchstone File Generation: Measured S-parameters saved as a .s2p file — compatible with Keysight, Rohde & Schwarz, Anritsu VNA software.

  3. Laser Marking & Anti-Counterfeit Code: Each connector body laser-etched with unique serial number + 8-digit anti-counterfeit code.

  4. SN Traceability: Login to s2p.coax-rf.cn with SN + 8-digit code to download the factory Touchstone file, test configuration, and material certification.


Electrical Performance

  • Characteristic Impedance: 50Ω ±2Ω (RF version) / 75Ω ±2Ω (video version)

  • Frequency Range: 50Ω: DC–4GHz (standard) / DC–10GHz (precision); 75Ω: DC–1GHz (standard) / DC–4GHz (broadcast)

  • Return Loss: ≥ 20dB (typical, 50Ω standard @ ≤2GHz)

  • Insertion Loss: ≤ 0.1 × √f(GHz) dB (50Ω standard)

  • Dielectric Withstanding Voltage: 500 V RMS (at sea level, 60Hz)

  • Working Voltage: 170 V RMS (50Ω) / 250 V RMS (75Ω)

  • Insulation Resistance: ≥ 1000 MΩ (at 100 V DC)

  • Center Contact Resistance: ≤ 5 mΩ

  • Outer Contact Resistance: ≤ 3 mΩ

  • RF Leakage: ≥ 50 dB isolation (DC–4GHz)

Mechanical Performance

  • Coupling Mechanism: Push-and-1/4-turn dual-bayonet lock

  • Mating Cycles: ≥ 500

  • Center Contact Retention: ≥ 10 N (captivated)

  • Mounting Options: Through-hole straight, right-angle, panel mount, 4-hole flange

Materials & Structure

  • Body / Shell: Brass, nickel-plated

  • Center Contact: Beryllium copper or phosphor bronze, gold-plated ≥ 1.27μm per MIL-G-45204

  • Dielectric: PTFE (Teflon)

  • Plating: Nickel per QQ-N-290; Gold per MIL-G-45204

  • Laser Marking: Unique SN + 8-digit code, etched into body

Environment & Compliance

  • Operating Temperature: -65℃ ~ +165℃

  • RF Interface Compliance: IEC 61169-8 / MIL-PRF-39012 / CECC 22120

  • RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))

  • Quality System: ISO 9001:2015

  • Traceability: 100% SN-marked; Touchstone file downloadable via s2p.coax-rf.cn

Adaptation & Installation

  • ⚠️ Bayonet Coupling — Push and 1/4-Turn Only: BNC uses a dual-spring bayonet mechanism. Push the plug in fully, then rotate 1/4 turn clockwise until the bayonet locks. Never force beyond the mechanical stop.

  • ⚠️ Do NOT Over-Tighten: Unlike threaded connectors, BNC requires no torque wrench. Over-rotation or using pliers will damage the bayonet springs.

  • ⚠️ 50Ω vs 75Ω — Verify Impedance Before Connecting: Using a 50Ω BNC in a 75Ω system (or vice versa) will cause a severe impedance mismatch (VSWR > 1.5). Always verify the impedance rating marked on the connector body.

  • ⚠️ 4-Hole Flange — Torque Sequence: For the 4-hole flange version, tighten screws in a cross pattern to 2.0–2.5 in-lbs (0.23–0.28 N·m) to prevent dielectric misalignment.

  • ⚠️ SN + 8-Digit Code Required for Touchstone: Both SN and 8-digit code must be available to download the factory Touchstone file from s2p.coax-rf.cn. Lost codes cannot be recovered.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

Oscilloscope Front Panel

CW-BNC-M-TH (Through-Hole)

Robust, serviceable

Test equipment I/O

Signal Generator Backplane

CW-BNC-M-RA (Right-Angle)

Low-profile 90° exit

Rack-mount instrument

Security DVR Motherboard

CW-BNC-M-PNL (Panel Mount)

Front-panel access

CCTV video input

Vehicular Radio Enclosure

CW-BNC-M-4HF (4-Hole Flange)

Max vibration resistance

Mobile test system

Lab Test Adapter Kit

CW-BNC-SMA-MF (to SMA)

Bridge to VNA

Production test

Broadcast Video Router

CW-BNC-HDBNC-MF (to HD BNC)

Hybrid high-density

Studio patch bay


Standard Matrix & Extensions

  • 15 Standard Models: 4 PCB-mount male + 3 same-series + 8 cross-series

  • Dual Impedance: 50Ω RF (DC–4GHz std / DC–10GHz precision) / 75Ω Video (DC–1GHz std / DC–4GHz broadcast)

  • Full Kit: Connector + SN card + anti-counterfeit code + Touchstone download instruction (s2p.coax-rf.cn) + bayonet coupling guide

⚡ Electrical Performance Customization

  • Precision 10GHz Version: Extended-frequency 50Ω for metrology-grade applications (VSWR ≤1.15 @ DC–4GHz)

  • Low-PIM Option: For multi-carrier test systems requiring PIM < -140dBc

Structural Customization

  • Custom Flange Patterns: Non-standard hole spacing for legacy equipment panels

  • Custom Barrel Lengths: Extended M-M or F-F adapters for unique patch-bay spacing

️ Material & Environmental Customization

  • All-Gold Construction: Gold flash over nickel for maximum corrosion resistance in humid environments

  • Enhanced Gold Thickness: 1.27μm minimum gold on center contact for >1000 cycle life in ATE

SN Traceability & Service

  • 100% Unique Serial Number: Laser-etched on every body

  • Touchstone File Download: Login to s2p.coax-rf.cn with SN + 8-digit code to access factory S2P file

  • Test Report Includes: VNA model, calibration method, sweep range (10MHz–4GHz or 10GHz), S11/S21 data

  • Rapid Prototyping: Standard 2–3 weeks; custom cable assemblies 3–4 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • BNC bayonet coupling procedure (push-and-1/4-turn verification)

    • 50Ω vs 75Ω identification guide to prevent field mismatches

    • 4-hole flange torque sequence for vibration-proof mounting

    • Cross-series adapter bandwidth limits (SMA, TNC, N-Type, UHF, SMB, HD BNC, F-Type, RCA)

    • Touchstone file interpretation for 4GHz/10GHz de-embedding


Tip

"There is no perfect standard part, only the most suitable solution."


Oscilloscope Front Panel — Through-Hole Straight Plug

  • Setup: Test equipment manufacturer building a 4-channel oscilloscope. Front-panel BNC outputs require robust, serviceable connectors. Use CW-BNC-M-TH (50Ω).

  • Workflow: 4 through-hole plugs hand-soldered to mainboard. Front panel cutouts align with plugs. External BNC cables connect with standard push-and-1/4-turn. System return loss ≥20dB @ 1GHz. 500+ mating cycles over 10 years of lab use.

  • Why This Connector: Through-hole provides mechanical strength for frequent cable connection. 50Ω precision ensures signal integrity. Familiar bayonet coupling reduces operator training. Touchstone file confirms compliance.

Broadcast SDI Router — 4-Hole Flange Plug

  • Setup: TV studio installing a 64×64 3G-SDI video router. High-vibration environment from cooling fans. Use CW-BNC-M-4HF (75Ω broadcast version, DC–4GHz).

  • Workflow: 64 flange-mount plugs secured with M2.5 screws in cross-torque pattern. BNC-jack-terminated Belden 1694A cables connect. System return loss ≥20dB @ 100MHz. Uncompressed HD-SDI transmitted without bit errors.

  • Why This Connector: 4-hole flange provides maximum vibration resistance. 75Ω broadcast version optimized for SDI return-loss mask. PTFE dielectric stable across full temperature range.

Medical Test Instrument — Right-Angle Plug

  • Setup: Portable medical diagnostic device. Internal PCB connects to front-panel BNC. Space-constrained. Use CW-BNC-M-RA (50Ω).

  • Workflow: Right-angle plug surface-mounted to PCB. Front-panel cutout aligns. External BNC cable connects. 90° exit routes cable parallel to enclosure wall, saving 8mm depth. System return loss ≥20dB @ 500MHz.

  • Why This Connector: Right-angle exit reduces chassis depth. 50Ω precision for RF measurement signals. PTFE dielectric stable from -65℃ to +165℃ for medical environments.

⚠️ Usage Red Lines

  • ⚠️ BAYONET COUPLING — PUSH FULLY BEFORE ROTATING:

    • Never rotate without pushing in first. Incomplete engagement causes high VSWR and intermittent connection.


  • ⚠️ 50Ω vs 75Ω — SEVERE MISMATCH IF CROSSED:

    • Connecting a 50Ω plug to a 75Ω jack (or vice versa) causes VSWR > 1.5. Always verify impedance before mating.


  • ⚠️ NO TORQUE WRENCH — HAND ONLY:

    • BNC bayonet requires no tools. Over-tightening with pliers will permanently damage the spring fingers.


  • ⚠️ 4-HOLE FLANGE — CROSS-TORQUE PATTERN:

    • Always tighten screws in a cross pattern to 2.0–2.5 in-lbs. Uneven torque will warp the flange and misalign the dielectric.


  • ⚠️ SN + 8-DIGIT CODE REQUIRED FOR TOUCHSTONE:

    • Both SN and 8-digit code must be available to download the factory Touchstone file from s2p.coax-rf.cn. Lost codes cannot be recovered.



Tip: "There is no perfect standard part, only the most suitable solution."

Coaxwave BNC male PCB-mount connectors are engineered as the definitive 50Ω/75Ω bayonet interconnect for test, video, and medical applications — brass nickel bodies, BeCu/phosphor bronze gold-plated centers (≥1.27μm), and PTFE dielectrics deliver DC–4GHz/10GHz performance with full SN traceability. Every connector is VNA-verified, laser-marked, and ships with a downloadable Touchstone file embodying "German precision, French engineering logic." With 15 standard models spanning PCB-mount plugs, same-series adapters, and cross-series transitions, Coaxwave delivers the most suitable BNC solution for your exact requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com