oaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstoneoaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstone
  • oaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstone
  • oaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstone
  • 1/2
  • oaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstone
  • oaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstone

oaxwave 2.92mm to 3.5mm Adapter DC-34GHz VSWR≤1.15 | Precision Cross-Series K-to-3.5mm | 12 Models Straight/NMD/Right-Angle/Flange | SN-Traceable Touchstone

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 2.92mm-to-3.5mm Cross-Series Adapters are 50Ω air-dielectric precision bridges between K-band (2.92mm) and 3.5mm interfaces. Both share 1/4-36 UNS threads and are mechanically intermateable. Standard grade: DC–26.5GHz, VSWR ≤1.20. Precision grade: DC–34GHz, VSWR ≤1.15. 12+ models: straight (4 genders), NMD protective head, 90° right-angle, 4-hole flange, bulkhead. SUS303 passivated body, BeCu gold-plated center, PEI/PTFE dielectric. 100% laser-marked SN + 8-digit code; factory Touchstone (.s2p) downloadable. Built to "German precision, French engineering logic."
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave 2.92mm-to-3.5mm Cross-Series Adapters are precision 50Ω air-dielectric bridges purpose-built for laboratories and ATE facilities operating across the K-band (2.92mm) and 3.5mm precision interface boundary. The fundamental advantage of this pairing is that 2.92mm and 3.5mm share the same 1/4-36 UNS thread pitch and are mechanically intermateable — but the electrical bandwidth is governed by the 3.5mm side. Coaxwave offers two performance tiers: Standard Grade (DC–26.5GHz, VSWR ≤ 1.20) for general-purpose lab use, and Precision Grade (DC–34GHz, VSWR ≤ 1.15) for metrology and aerospace calibration where every 0.01 of VSWR counts.

The product line covers 12 standard models across five mechanical families:

No.

Model Family

2.92mm End

3.5mm End

Configuration

Max Freq

Notes

1

CW-292-35-MM-STR

2.92mm Male

3.5mm Male

Straight

DC–34GHz*

In-line K-to-3.5mm barrel

2

CW-292-35-MF-STR

2.92mm Male

3.5mm Female

Straight

DC–34GHz*

Most common test bridge

3

CW-292-35-FM-STR

2.92mm Female

3.5mm Male

Straight

DC–34GHz*

Reverse-gender bridge

4

CW-292-35-FF-STR

2.92mm Female

3.5mm Female

Straight

DC–34GHz*

In-line F-F coupler

5

CW-292-35-MF-NMD

2.92mm Male

3.5mm Female

NMD Protective Head

DC–34GHz*

VNA port saver + 3.5mm

6

CW-292-35-FF-NMD

2.92mm Female

3.5mm Female

NMD Protective Head

DC–34GHz*

NMD F-F bridge

7

CW-292-35-MM-RA

2.92mm Male

3.5mm Male

90° Right-Angle

DC–34GHz*

Space-constrained routing

8

CW-292-35-MF-RA

2.92mm Male

3.5mm Female

90° Right-Angle

DC–34GHz*

Right-angle test port

9

CW-292-35-FM-RA

2.92mm Female

3.5mm Male

90° Right-Angle

DC–34GHz*

Reverse-gender right-angle

10

CW-292-35-FF-RA

2.92mm Female

3.5mm Female

90° Right-Angle

DC–34GHz*

Right-angle coupler

11

CW-292-35-MF-4HF

2.92mm Male

3.5mm Female

4-Hole Flange

DC–34GHz*

Panel-mount K-to-3.5mm

12

CW-292-35-MF-BH

2.92mm Male

3.5mm Female

Bulkhead

DC–34GHz*

Wall penetration

* Precision Grade: DC–34GHz, VSWR ≤1.15. Standard Grade: DC–26.5GHz, VSWR ≤1.20. Both tiers available across all 12 models — specify grade at order.

💡 Every model is 100% VNA-tested to its rated upper frequency, laser-marked with a unique serial number, and linked to a downloadable factory Touchstone (.s2p) file.

Key Performance (Coaxwave 2.92mm ↔ 3.5mm specification):

  • Frequency Range: DC–26.5GHz (Standard); DC–34GHz (Precision)

  • VSWR: ≤ 1.20:1 (Standard); ≤ 1.15:1 (Precision)

  • Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)

  • Durability: ≥ 500 mating cycles (Standard); ≥ 1000 cycles (Precision, NMD models)

  • Thread Compatibility: Both ends 1/4-36 UNS — mechanically intermateable with each other's cables and standards

🎯 Core Positioning: The K-to-3.5mm Bridge — Where 34GHz Precision Meets Mechanical Compatibility

The 2.92mm and 3.5mm connectors are the only two standardized RF interfaces that share the same 1/4-36 UNS thread pitch, same outer conductor diameter, and same center contact geometry — they are mechanically intermateable in both directions. This makes the 2.92mm ↔ 3.5mm transition unique: it is not a forced adaptation but a natural extension of the same precision air-dielectric architecture. Coaxwave exploits this by engineering the transition zone as a continuous 50Ω air line with a minimal PEI support bead — delivering VSWR ≤ 1.15 at 34GHz (Precision Grade) with insertion loss as low as 0.05√f(GHz) dB.

⚡ Complete 12-Model Interface Matrix

① Straight (4 Genders)

  • 2.92mm M ↔ 3.5mm M / M ↔ F / F ↔ M / F ↔ F: In-line bridges for daily calibration, cable extension, and equipment interfacing. The M-F configuration is the lab standard: 2.92mm VNA port → 3.5mm calibration kit or cable.

② NMD Protective Head (2 Models)

  • 2.92mm M ↔ 3.5mm F / 2.92mm F ↔ 3.5mm F: NMD collar on the 2.92mm side shields the VNA port from mechanical wear while presenting a standard 3.5mm female to the test setup. Ideal for labs where the VNA has 2.92mm NMD ports but the calibration ecosystem is 3.5mm.

③ 90° Right-Angle (4 Genders)

  • All 4 gender combinations: Route RF lines in space-constrained enclosures — ATE fixtures, portable analyzers, and rack-mounted equipment where a straight adapter would place stress on the cable or panel.

④ Panel-Mount (4-Hole Flange + Bulkhead)

  • 2.92mm M ↔ 3.5mm F: Secure panel penetration. 2.92mm side faces inward (chamber/DUT); 3.5mm side faces outward (cable/instrument). For environmental chambers and production test racks.

🛡️ Coaxwave Quality Barrier — SN Traceability & Touchstone Delivery

Every 2.92mm-to-3.5mm Adapter undergoes four mandatory 100% controls:

  1. 100% VNA Full-Band S-Parameter Test: Swept from 10 MHz to 26.5GHz (Standard) or 34GHz (Precision). S11, S21 recorded. VSWR and insertion loss verified.

  2. Touchstone File Generation: Measured S-parameters saved as a .s2p file — compatible with Keysight, Rohde & Schwarz, Anritsu, Copper Mountain VNA software.

  3. Laser Marking & Anti-Counterfeit Code: Each adapter body laser-etched with unique serial number + 8-digit anti-counterfeit code. Etched into SUS303 — survives 1000+ cycles.

  4. SN-Traceability Portal: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability to download the factory Touchstone file, test configuration, and material certification.


Electrical Performance

  • Characteristic Impedance: 50Ω ±0.5Ω

  • Frequency Range: DC–26.5GHz (Standard); DC–34GHz (Precision)

  • VSWR: ≤ 1.20:1 (Standard); ≤ 1.15:1 (Precision)

  • Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)

  • Dielectric Withstanding Voltage: 500 V RMS (at sea level, 60Hz)

  • Insulation Resistance: ≥ 5000 MΩ (at 500 V DC)

  • RF Leakage: ≥ 100 dB isolation

Mechanical Performance

  • Coupling Mechanism: 1/4-36 UNS threaded (both ends); NMD collar on NMD models (mechanical only)

  • Recommended Torque: 2.92mm side 1.1–1.3 N·m; 3.5mm side 1.1–1.3 N·m (calibrated torque wrench for both)

  • Mating Cycles: ≥ 500 (Standard); ≥ 1000 (Precision, NMD models)

  • Center Contact Retention: ≥ 30 N (captivated)

  • Mounting Options: Straight, 90° right-angle, NMD protective head, 4-hole flange, bulkhead

Materials & Structure

  • Body / Shell: SUS303 stainless steel, passivated — dimensional stability and corrosion resistance

  • Center Contact: Beryllium copper, gold-plated per MIL-G-45204

  • Dielectric: Air + PEI support bead (2.92mm side); PTFE or PEI (3.5mm side)

  • Plating: Gold per MIL-G-45204; passivation per AMS 2700

  • Laser Marking: Unique SN + 8-digit code, etched into SUS303 body

Environment & Compliance

  • Operating Temperature: -65℃ ~ +165℃

  • RF Interface Compliance: 2.92mm per IEEE 287 / MIL-STD-348; 3.5mm per IEEE 287 / MIL-STD-348

  • RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))

  • Quality System: ISO 9001:2015 / AS9100D

  • Traceability: 100% SN-marked; Touchstone file downloadable via SN + 8-digit code

Adaptation & Installation

  • ⚠️ Precision Grade Reaches 34GHz — Standard Grade Stops at 26.5GHz: The 3.5mm interface theoretically supports 34GHz. Coaxwave Precision Grade achieves this; Standard Grade is validated to 26.5GHz. Specify Precision Grade when your application requires >26.5GHz to 34GHz.

  • Torque Both Ends to 1.1–1.3 N·m: Both interfaces use the same thread. Use a calibrated torque wrench. Over-torquing either side deforms the air-dielectric gap → VSWR spike at 26.5GHz+.

  • ⚠️ NMD Collar — Hand-Tight Only: On NMD models, the outer collar is a mechanical shield. Never apply wrench torque to the collar. Torque only the inner 2.92mm thread.

  • Right-Angle Orientation: Note the bend direction relative to panel clearance. Custom bend angles available on request.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

34GHz VNA Calibration Lab

CW-292-35-MF-STR (Precision)

VSWR≤1.15, 34GHz

National metrology SOLT

ATE Production (Ka/Ka过渡)

CW-292-35-MF-4HF (Precision)

4-hole flange, panel mount

Satellite module test rack

VNA Port Protection

CW-292-35-MF-NMD (Precision)

NMD collar, >1000 cycles

Daily calibration port saver

Portable Test Equipment

CW-292-35-MF-RA (Standard)

Right-angle, compact

Handheld analyzer routing

Environmental Chamber

CW-292-35-MF-BH (Precision)

Bulkhead, sealed, 34GHz

Temperature-cycling DUT

Mixed-Interface Lab

CW-292-35-FM-STR (Standard)

Reverse-gender, F-M

3.5mm source to 2.92mm input

Field Service Kit

CW-292-35-FF-STR (Standard)

F-F coupler, inline

Quick gender adaptation

Standard Matrix & Extensions

  • 12 Standard Models: 4 straight + 4 right-angle + 2 NMD + 2 panel-mount (flange/bulkhead)

  • Two Performance Tiers: Standard (DC–26.5GHz, VSWR≤1.20) / Precision (DC–34GHz, VSWR≤1.15)

  • Full Kit: Adapter + SN card + anti-counterfeit code + Touchstone download instruction + torque chart

⚡ Electrical Performance Customization

  • Ultra-Precision Grade: VSWR ≤ 1.10 for national metrology institute applications

  • Phase-Matched Sets: Multiple adapters matched for TRL calibration at K/Ka-band

Structural Customization

  • Custom Right-Angle Orientation: 45°, 135°, or custom bend planes

  • Custom Flange Patterns: Non-standard hole spacing for legacy ATE fixtures

️ Material & Environmental Customization

  • Titanium Body: Non-magnetic for quantum/cryogenic applications

  • Heavy Gold Plating: Thick gold for >2000-cycle ATE environments

  • All-PEI Dielectric: For low-outgassing space-flight applications

SN Traceability & Service

  • 100% Unique Serial Number: Laser-etched on every SUS303 body

  • Touchstone File Download: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability

  • Test Report Includes: VNA model, calibration method, sweep range, S11/S21 data

  • Rapid Prototyping: Standard 2–3 weeks; custom 4–5 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • Standard vs. Precision grade selection guidance

    • Torque procedure for both 1/4-36 UNS interfaces

    • Right-angle orientation for panel layout

    • Touchstone file interpretation for fixture de-embedding


Tip

"There is no perfect standard part, only the most suitable solution."

34GHz Metrology Lab — Precision Straight M-F

  • Setup: National metrology institute, 34GHz VNA with 2.92mm modules. Calibration kit is 3.5mm. Use CW-292-35-MF-STR (Precision Grade).

  • Workflow: Adapter torqued to VNA (1.2 N·m) and calibration kit (1.2 N·m). SOLT performed. S2P imported. Calibration residual ≤ 0.02 dB at 30GHz.

  • Why This Adapter: VSWR ≤1.15 at 34GHz minimizes calibration residual. Precision-grade air-dielectric transition preserves measurement integrity. SN traceability supports ISO 17025.

ATE Production — 4-Hole Flange Panel Mount

  • Setup: Ka-band transponder production, 200 units/day. Test fixture requires panel-mounted 34GHz reference. Use CW-292-35-MF-4HF (Precision Grade).

  • Workflow: Adapter flange-mounted on fixture. 2.92mm male faces DUT board. 3.5mm female faces operator SMA/3.5mm cable. 200 DUTs/day. S21 repeatability ≤ 0.04 dB over 6 months.

  • Why This Adapter: 4-hole flange provides secure mounting. 34GHz bandwidth covers full Ka-band. SUS303 body survives production floor.

VNA Port Protection — NMD Precision

  • Setup: Aerospace lab, daily 34GHz calibration. VNA has 2.92mm NMD ports. Use CW-292-35-MF-NMD (Precision Grade).

  • Workflow: NMD collar engaged with VNA port. Inner thread torqued to 1.2 N·m. Connected to 3.5mm cable. After 1000 cycles, VNA port pristine, adapter VSWR drift < 0.02.

  • Why This Adapter: NMD collar absorbs all mechanical wear. Precision grade delivers VSWR≤1.15. Touchstone file enables exact de-embedding.

⚠️ Usage Red Lines

  • ⚠️ PRECISION GRADE = 34GHz / STANDARD GRADE = 26.5GHz:

    • Specify Precision Grade when your application requires >26.5GHz. Standard Grade is validated only to 26.5GHz.


  • ⚠️ BOTH ENDS 1.1–1.3 N·m — USE CALIBRATED WRENCH:

    • Both interfaces share the same thread. Over-torquing either side → air-gap deformation → VSWR spike.


  • ⚠️ NMD COLLAR — HAND-TIGHT ONLY:

    • Never wrench-tighten the NMD collar. Torque only the inner 2.92mm thread.


  • ⚠️ SN + 8-DIGIT CODE REQUIRED FOR TOUCHSTONE:

    • Both SN and 8-digit code must be entered at www.coaxial-rf.com/sn-traceability. Lost codes cannot be recovered.



Tip: "There is no perfect standard part, only the most suitable solution."

Coaxwave 2.92mm-to-3.5mm Cross-Series Adapters are engineered as precision air-dielectric bridges between K-band and 3.5mm interfaces — SUS303 bodies, BeCu gold-plated centers, and PEI/PTFE dielectrics deliver VSWR ≤1.15 to 34GHz (Precision Grade) with full SN traceability. Every adapter is VNA-verified, laser-marked, and ships with a downloadable Touchstone file embodying "German precision, French engineering logic." With 12 standard models spanning straight, right-angle, NMD, and panel-mount configurations in two performance tiers, Coaxwave delivers the most suitable 2.92mm-to-3.5mm solution for your exact cross-series requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com