Coaxwave 2.4mm NMD Test Port Adapter DC-50GHz VSWR≤1.25 | >2000 Cycles SUS303 | VNA Port Saver | SN-Traceable Touchstone | Metrology Grade
  • Coaxwave 2.4mm NMD Test Port Adapter DC-50GHz VSWR≤1.25 | >2000 Cycles SUS303 | VNA Port Saver | SN-Traceable Touchstone | Metrology Grade
  • 1/1
  • Coaxwave 2.4mm NMD Test Port Adapter DC-50GHz VSWR≤1.25 | >2000 Cycles SUS303 | VNA Port Saver | SN-Traceable Touchstone | Metrology Grade

Coaxwave 2.4mm NMD Test Port Adapter DC-50GHz VSWR≤1.25 | >2000 Cycles SUS303 | VNA Port Saver | SN-Traceable Touchstone | Metrology Grade

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 2.4mm NMD Test Port Adapter is a ruggedized 50Ω precision interconnect for VNA and NMD-style test ports, DC–50GHz, VSWR ≤1.25, insertion loss ≤0.05√f(GHz) dB, >2000 mating cycles. SUS303 passivated stainless steel body, BeCu gold-plated center. NMD outer thread absorbs mechanical wear, protecting expensive instrument ports. 12 standard models cover same-series (NMD 2.4 F to 2.4 M/F, NMD to NMD) and cross-series to 2.92mm, 3.5mm, 1.85mm, plus panel-mount. 100% SN-laser-marked; factory Touchstone downloadable via SN + 8-digit code.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Coaxwave 2.4mm NMD Test Port Adapters are purpose-engineered 50Ω precision interconnects designed as the definitive Test Port Saver for vector network analyzers and NMD-style instrument ports. Operating from DC to 50GHz, these adapters feature a VSWR ≤ 1.25 and insertion loss ≤ 0.05√f(GHz) dB — performance that preserves measurement integrity while shielding the VNA's internal connector from the physical abuse of daily calibration cycles.

The defining feature is the NMD (Non-Mating Device) architecture: an outer threaded collar mates with the VNA port's NMD profile, absorbing all torsional load, cable pull, and accidental impact. The inner 2.4mm precision interface handles the RF signal path with no mechanical stress transferred to the instrument. This two-stage design delivers > 2000 mating cycles with stable electrical performance — the VNA port itself remains pristine.

All 12 Standard Transfer Models:

No.

Model Family

End A

End B

Configuration

Max Freq

Notes

1

CW-24NMD-24-MF-STR

NMD 2.4mm Female

2.4mm Male

Straight

DC–50GHz

VNA port to cable

2

CW-24NMD-24-FF-STR

NMD 2.4mm Female

2.4mm Female

Straight

DC–50GHz

VNA port to F-F fixture

3

CW-24NMD-24NMD-M-STR

NMD 2.4mm Female

NMD 2.4mm Male

Straight (NMD-to-NMD)

DC–50GHz

NMD port extension

4

CW-24NMD-24-MF-BH

NMD 2.4mm Female

2.4mm Male

Bulkhead

DC–50GHz

Panel feedthrough

5

CW-24NMD-24-FF-BH

NMD 2.4mm Female

2.4mm Female

Bulkhead

DC–50GHz

Panel F-F feedthrough

6

CW-24NMD-292-MF-STR

NMD 2.4mm Female

2.92mm (K) Male

Straight

DC–40GHz*

V-to-K bridge

7

CW-24NMD-292-FF-STR

NMD 2.4mm Female

2.92mm (K) Female

Straight

DC–40GHz*

V-to-K F-F bridge

8

CW-24NMD-35-MF-STR

NMD 2.4mm Female

3.5mm Male

Straight

DC–26.5GHz*

V-to-3.5mm bridge

9

CW-24NMD-35-FF-STR

NMD 2.4mm Female

3.5mm Female

Straight

DC–26.5GHz*

V-to-3.5mm F-F bridge

10

CW-24NMD-185-M-STR

NMD 2.4mm Female

1.85mm (V) Male

Straight

DC–50GHz

V-to-V bridge (50GHz)

11

CW-24NMD-24-MF-2HF

NMD 2.4mm Female

2.4mm Male

2-Hole Flange

DC–50GHz

Compact panel mount

12

CW-24NMD-24-MF-4HF

NMD 2.4mm Female

2.4mm Male

4-Hole Flange

DC–50GHz

Secure panel mount

* System bandwidth governed by the lower-rated interface. The 2.4mm NMD side always maintains DC–50GHz.

💡 Every model is 100% VNA-tested from 10 MHz to its upper frequency limit, laser-marked with a unique serial number, and linked to a downloadable factory Touchstone (.s2p) file.

🎯 Core Positioning: The Test Port Saver — Protect Your VNA Investment

A VNA's test port is its most vulnerable — and expensive — component. Every cable tug, every misaligned coupling nut, every 500-cycle calibration session wears the port's center contact and dielectric. Coaxwave 2.4mm NMD Adapters act as a sacrificial protective layer: the NMD collar takes the mechanical punishment; the instrument port stays untouched. When the adapter eventually wears out after 2000+ cycles, you replace a $200 adapter — not a $15,000 VNA port module.

⚡ Complete 12-Model Interface Matrix

Same-Series (NMD 2.4mm ↔ 2.4mm)

  • NMD F to 2.4mm M/F (Straight): Direct VNA-to-cable connection. Most common lab configuration.

  • NMD F to NMD M (Straight): NMD-to-NMD port extension for deep-reach applications.

  • Bulkhead M-F / F-F: Panel-mount feedthrough for environmental chambers and ATE fixtures.

  • 2-Hole / 4-Hole Flange: Secure panel penetration for production test racks.

Cross-Series Bridges

  • To 2.92mm (K): NMD 2.4mm F ↔ 2.92mm M/F — 40GHz bridge for Ka-band DUTs on 50GHz VNAs.

  • To 3.5mm: NMD 2.4mm F ↔ 3.5mm M/F — 26.5GHz bridge for legacy equipment.

  • To 1.85mm (V): NMD 2.4mm F ↔ 1.85mm M — Full 50GHz bridge (both interfaces support 50GHz).

🛡️ Coaxwave Quality Barrier — SN Traceability & Touchstone Delivery

Every 2.4mm NMD Adapter undergoes four mandatory 100% controls:

  1. 100% VNA Full-Band S-Parameter Test: Swept from 10 MHz to 50GHz (or lower for cross-series). S11, S21 recorded.

  2. Touchstone File Generation: Measured S-parameters saved as a .s2p file — compatible with Keysight, Rohde & Schwarz, Anritsu, Copper Mountain VNA software.

  3. Laser Marking & Anti-Counterfeit Code: Each adapter body laser-etched with unique serial number + 8-digit anti-counterfeit code. Etched into SUS303 — survives 2000+ cycles and lab solvents.

  4. SN-Traceability Portal: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability to download the factory Touchstone file, test configuration, and material certification.


Electrical Performance

  • Characteristic Impedance: 50Ω ±0.5Ω

  • Frequency Range: DC–50GHz (2.4mm side); DC–40GHz (to 2.92mm); DC–26.5GHz (to 3.5mm)

  • VSWR: ≤ 1.25:1 (maximum, DC–50GHz)

  • Insertion Loss: ≤ 0.05 × √f(GHz) dB (typical, per mated pair)

  • RF Leakage: ≥ 100 dB isolation (DC–50GHz)

Mechanical Performance

  • Coupling Mechanism: NMD outer collar (mechanical) + precision 2.4mm inner thread (electrical)

  • Recommended Torque: 0.8–1.0 N·m (inner 2.4mm thread, calibrated torque wrench); NMD collar hand-tight or per VNA manufacturer spec

  • Mating Cycles: > 2000 (NMD design; instrument port remains unworn)

  • Center Contact Retention: ≥ 30 N (captivated)

  • Mounting Options: Straight, bulkhead, 2-hole flange, 4-hole flange

Materials & Structure

  • Body / Shell: SUS303 stainless steel, passivated — dimensional stability and corrosion resistance

  • Center Contact: Beryllium copper, gold-plated per MIL-G-45204

  • Dielectric: PEEK / PEI support beads — low loss, high thermal stability

  • Plating: Gold per MIL-G-45204; passivation per AMS 2700

  • Laser Marking: Unique SN + 8-digit code, etched into SUS303

Environment & Compliance

  • Operating Temperature: -55℃ ~ +165℃

  • RF Interface Compliance: IEEE 287 / MIL-STD-348 (2.4mm); IEEE 287 (2.92mm, 3.5mm, 1.85mm)

  • RoHS / REACH: Compliant (gold plating exemption)

  • Quality System: ISO 9001:2015 / AS9100D

  • Traceability: 100% SN-marked; Touchstone downloadable via SN + 8-digit code

Adaptation & Installation

  • NMD Collar First: Engage the NMD collar with the VNA port before touching the inner thread. The collar aligns the adapter mechanically.

  • Inner Thread Torque: 0.8–1.0 N·m with a calibrated wrench. Never exceed 1.0 N·m — over-torque deforms the air gap at 50GHz.

  • ⚠️ Never Torque the NMD Collar: The collar is a mechanical shield. Wrench torque on the collar damages the VNA's NMD profile.

  • ⚠️ Cross-Series Frequency Limits: To 2.92mm = 40GHz; to 3.5mm = 26.5GHz; to 1.85mm = 50GHz. Plan your calibration chain accordingly.


Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

50GHz VNA Daily Calibration

CW-24NMD-24-MF-STR

NMD collar, >2000 cycles

Lab SOLT, port extension

ATE Production Test

CW-24NMD-24-MF-4HF

4-hole flange, panel mount

Automotive radar ATE

Environmental Chamber

CW-24NMD-24-MF-BH

Bulkhead, sealed feedthrough

Temperature-cycling DUT

Ka-Band DUT on 50GHz VNA

CW-24NMD-292-MF-STR

V-to-K bridge, 40GHz

Satellite transponder test

Legacy Equipment Interface

CW-24NMD-35-FF-STR

V-to-3.5mm, 26.5GHz

Mixed-instrument lab

Deep-Reach VNA Port

CW-24NMD-24NMD-M-STR

NMD-to-NMD extension

Dense rack VNA access

Secure Panel Mount

CW-24NMD-24-MF-2HF

2-hole flange, compact

Portable test enclosure


Standard Matrix & Extensions

  • 12 Standard Models: 3 same-series straight + 3 bulkhead/flange + 6 cross-series (2.92mm/3.5mm/1.85mm, M & F)

  • Gender Variants: NMD 2.4mm M to 2.4mm M (straight) available on custom request

  • Full Kit: Adapter + SN card + anti-counterfeit code + Touchstone guide + NMD mating protocol

⚡ Electrical Performance Customization

  • Precision Grade: VSWR ≤ 1.15 for national metrology institute applications

  • Phase-Matched Sets: Multiple adapters matched for TRL calibration at K/Ka-band

Structural Customization

  • Custom Flange Patterns: Non-standard hole spacing for legacy ATE fixtures

  • Extended Barrel: For deep-reach VNA port access

️ Material & Environmental Customization

  • Titanium Body: Non-magnetic for quantum/cryogenic applications

  • Heavy Gold Plating: For >5000-cycle ATE environments

SN Traceability & Service

  • 100% Unique Serial Number: Laser-etched on every SUS303 body

  • Touchstone Download: Enter SN + 8-digit code at www.coaxial-rf.com/sn-traceability

  • Rapid Prototyping: Standard 2–3 weeks; custom 4–5 weeks

  • Application Engineering: Coaxwave RF engineers provide NMD mating training, torque specs, cross-series budgeting, and Touchstone interpretation.

Tip

"There is no perfect standard part, only the most suitable solution."


50GHz VNA Daily Calibration — NMD 2.4mm F to 2.4mm M

  • Setup: Aerospace lab, 50GHz VNA. Daily SOLT calibration needed. Use CW-24NMD-24-MF-STR.

  • Workflow: NMD collar engaged with VNA port. Inner thread torqued to 0.9 N·m. Connected to 2.4mm calibration kit. After 2000 cycles, VSWR drift < 0.03. VNA port remains pristine.

  • Why This Adapter: NMD collar absorbs all wear. >2000 cycle life = 2+ years of daily use. Touchstone file enables exact fixture de-embedding.

ATE Production — 4-Hole Flange Panel Mount

  • Setup: Automotive radar ATE, 77GHz modules. Test fixture requires panel-mounted 50GHz reference. Use CW-24NMD-24-MF-4HF.

  • Workflow: Adapter flange-mounted on test fixture wall. NMD side faces VNA cable. 2000+ DUTs tested daily. S21 repeatability ≤ 0.05 dB over 6 months.

  • Why This Adapter: 4-hole flange provides secure mounting. NMD design protects VNA port from operator handling errors.

V-to-K Band Bridge — NMD 2.4mm F to 2.92mm M

  • Setup: Satellite payload, 50GHz VNA, Ka-band DUT (2.92mm). Use CW-24NMD-292-MF-STR.

  • Workflow: Adapter connects VNA to DUT. System = 40GHz. S-parameters measured, de-embedded with factory S2P.

  • Why This Adapter: Enables 40GHz measurement without custom cables. VSWR ≤1.25 ensures minimal reflection.

⚠️ Usage Red Lines

  • ⚠️ NMD COLLAR — HAND-TIGHT ONLY, NEVER WRENCH:

    • Wrench torque on the NMD collar permanently damages the VNA's NMD port profile.

    • Always hand-tighten the collar. Apply calibrated 0.8–1.0 N·m torque ONLY to the inner 2.4mm thread.


  • ⚠️ CROSS-SERIES FREQUENCY LIMITS:

    • To 2.92mm = 40GHz max. To 3.5mm = 26.5GHz max. To 1.85mm = 50GHz.

    • System bandwidth = lower-rated interface. Never assume 50GHz with cross-series adapters.


  • ⚠️ SN + 8-DIGIT CODE REQUIRED FOR TOUCHSTONE:

    • Both SN and 8-digit code must be entered at www.coaxial-rf.com/sn-traceability. Lost codes cannot be recovered.



Tip: "There is no perfect standard part, only the most suitable solution."

Coaxwave 2.4mm NMD Test Port Adapters are engineered as the definitive VNA port saver — SUS303 precision, NMD collar architecture, and air-dielectric 50GHz design deliver >2000-cycle instrument protection with metrology-grade electrical performance. Every adapter is VNA-verified, laser-marked, and ships with a downloadable Touchstone file embodying "German precision, French engineering logic." With 12 standard models spanning same-series and cross-series configurations, Coaxwave delivers the most suitable 2.4mm NMD solution for your exact test-port requirement.

Sales Email: sales@coaxial-rf.com

Company Website: www.coaxial-rf.com