Architecture — Threaded Security, Broadcast-Grade Materials
Attribute | 75Ω N-Type Connector Specification |
|---|---|
Characteristic Impedance | 75Ω ±2Ω (75Ω version); 50Ω ±2Ω (50Ω version) |
Frequency Range | DC–1.5GHz (75Ω version); DC–11GHz (50Ω version) |
Coupling Mechanism | 5/8-24 UNEF threaded |
VSWR (Factory) | ≤ 1.15:1 (straight); ≤ 1.25:1 (right-angle) |
Body Material | Brass, nickel-plated |
Center Contact | Beryllium copper, gold-plated |
Dielectric Support | PTFE (Teflon®) |
Gasket / Seal | Silicone rubber O-ring (weather-sealed versions) |
Operating Temperature | -55℃ ~ +155℃ |
Mating Cycles | ≥ 500 (proper torque) |
Power Handling | ~100W @ 1GHz, 75Ω system (sea level, +40℃) |
All Transfer Models (representative cross-section — every combination across all gender sets and cross-series interfaces is supported):
No. | Model Family | End A | End B | Max Freq | Notes |
|---|---|---|---|---|---|
1 | CW-N75-N75-MM | 75Ω N Male | 75Ω N Male | DC–1.5GHz | In-line barrel |
2 | CW-N75-N75-MF | 75Ω N Male | 75Ω N Female | DC–1.5GHz | Standard jumper |
3 | CW-N75-N75-FF | 75Ω N Female | 75Ω N Female | DC–1.5GHz | Panel-to-panel |
4 | CW-N75-N50-MF | 75Ω N Male | 50Ω N Female | DC–1.5GHz* | 75→50Ω transition |
5 | CW-N75-BNC75-MF | 75Ω N Male | 75Ω BNC Female | DC–1.5GHz | Broadcast to CCTV |
6 | CW-N75-F75-MF | 75Ω N Male | 75Ω F-Type Female | DC–1.5GHz | CATV interface |
7 | CW-N75-RCA-MF | 75Ω N Male | RCA Female | DC–50MHz | Video format bridge |
8 | CW-N75-SMA-MF | 75Ω N Male | SMA Female | DC–1.5GHz* | RF test interface |
9 | CW-N75-TNC75-MF | 75Ω N Male | 75Ω TNC Female | DC–1.5GHz | Vibration-proof link |
10 | CW-N75-UHF-MF | 75Ω N Male | UHF SO-239 | DC–0.3GHz | Legacy/Ham bridge |
11 | CW-N75-BNC50-MF | 75Ω N Male | 50Ω BNC Female | DC–1.5GHz* | Cross-impedance |
12 | CW-N75-SMA-N75 | SMA Male | 75Ω N Female | DC–1.5GHz* | Test to broadcast |
13 | CW-N75-F75-N75 | F-Type Male | 75Ω N Female | DC–1.5GHz | CATV to studio |
14 | CW-N75-BNC75-N75 | 75Ω BNC Male | 75Ω N Female | DC–1.5GHz | CCTV to studio |
15 | CW-N75-TNC75-N75 | 75Ω TNC Male | 75Ω N Female | DC–1.5GHz | Mobile to studio |
* Cross-impedance adapters (75Ω↔50Ω) introduce a measurable VSWR step at the junction. Coaxwave designs these transitions with stepped inner/outer diameters to minimize reflection, but system designers should expect ~1.3:1 VSWR at the transition. For precision applications, use a resistive minimum-loss pad (MLP) instead.
💡 Every A-to-B combination across 75Ω N, 50Ω N, 75Ω BNC, 50Ω BNC, F-Type, RCA, SMA, 75Ω TNC, and UHF is supported. All genders (M/M, M/F, F/F), straight, 90° right-angle, 4-hole flange, bulkhead, and PCB-mount configurations available. Every connector is 100% VSWR-tested, hipot-tested, insulation-resistance-tested, and salt-spray-verified before shipment.
Key Performance (Coaxwave 75Ω N-Type specification):
Impedance: 75Ω ±2Ω (75Ω version)
Frequency Range: DC–1.5GHz (75Ω version); DC–11GHz (50Ω version)
VSWR: ≤ 1.15:1 (straight); ≤ 1.25:1 (right-angle)
Dielectric Withstanding Voltage: ≥ 1500V RMS (sea level)
Insulation Resistance: ≥ 5000 MΩ
Contact Resistance: Center ≤ 1.5 mΩ; Outer ≤ 1.0 mΩ
Inspection: 100% VSWR test + dielectric withstanding voltage (hipot) test + insulation resistance test + salt-spray verification. Each connector ships with individual serialized labeling and test data.
In broadcast facilities, CATV headends, and SDI video routing centers, the 75Ω N-Type is the connector that bridges the gap between BNC (low-power, quick-connect) and 7/16 DIN (high-power, bulky). It handles the transmitter output stages, distribution amplifier cascades, and antenna feed lines where BNC is under-rated but 7/16 is overkill. The 5/8-24 UNEF thread provides a positive lock that BNC's bayonet cannot match — critical when a loose connection means a dropped broadcast signal. For 75Ω systems operating up to 1.5GHz, this is the most robust, field-proven interconnect available.
Same-Series Gender Sets:
75Ω N Male to 75Ω N Male (CW-N75-N75-MM): In-line barrel adapters for extending cable runs.
75Ω N Male to 75Ω N Female (CW-N75-N75-MF): Standard cable-end connector.
75Ω N Female to 75Ω N Female (CW-N75-N75-FF): Panel-to-panel bulkhead feedthrough.
Cross-Series / Cross-Impedance Adapters:
75Ω N ↔ 50Ω N (CW-N75-N50-)*: Transition between broadcast (75Ω) and RF communications (50Ω) systems.
75Ω N ↔ 75Ω BNC (CW-N75-BNC75-)*: Interface studio equipment to CCTV or consumer video gear.
75Ω N ↔ F-Type (CW-N75-F75-)*: Connect CATV distribution networks to broadcast-grade amplifiers.
75Ω N ↔ RCA (CW-N75-RCA-)*: Bridge professional 75Ω N outputs to consumer composite video inputs.
75Ω N ↔ SMA (CW-N75-SMA-)*: Adapt broadcast equipment for RF test and measurement.
75Ω N ↔ 75Ω TNC (CW-N75-TNC75-)*: Add vibration resistance to mobile broadcast vehicles.
75Ω N ↔ UHF (CW-N75-UHF-)*: Legacy amateur radio and older CATV equipment interface.
Mounting Configurations:
Straight: Standard inline and panel-mount.
90° Right-Angle: Space-constrained rack and enclosure applications.
4-Hole Flange: Secure panel penetration for equipment front panels.
Bulkhead: Rear-mount for EMI-shielded enclosures.
PCB Mount: Edge-mount and through-hole for board-level integration.
Every 75Ω N-Type Connector undergoes four mandatory 100% controls:
100% VSWR Test: Measured across DC–1.5GHz. VSWR verified against ≤ 1.15:1 (straight) / ≤ 1.25:1 (right-angle) specification.
Dielectric Withstanding Voltage (Hipot) Test: 1500V RMS applied between center contact and outer conductor. No breakdown.
Insulation Resistance Test: ≥ 5000 MΩ verified between center and outer conductor at 500V DC.
Salt-Spray Verification: Per applicable environmental standard for outdoor and marine-rated versions.
Characteristic Impedance: 75Ω ±2Ω (75Ω version); 50Ω ±2Ω (50Ω version)
Frequency Range: DC–1.5GHz (75Ω version); DC–11GHz (50Ω version)
VSWR: ≤ 1.15:1 (straight); ≤ 1.25:1 (right-angle)
Dielectric Withstanding Voltage: ≥ 1500V RMS (sea level)
Insulation Resistance: ≥ 5000 MΩ
Contact Resistance: Center contact ≤ 1.5 mΩ; Outer contact ≤ 1.0 mΩ
Power Handling: ~100W @ 1GHz, 75Ω system (sea level, +40℃)
Coupling Mechanism: 5/8-24 UNEF threaded
Mating Torque: 1.1 N·m (8 in-lb) — use N-Type torque wrench
Mating Cycles: ≥ 500 (proper torque, clean threads)
Retention Force: Axial pull-off ≥ 200 N (mated)
Mounting Options: Straight, 90° right-angle, 4-hole flange, bulkhead, PCB edge-mount
Body / Shell: Brass, nickel-plated (standard); passivated stainless steel (marine/defense, on request)
Center Contact: Beryllium copper, gold-plated (1.27 µm min)
Dielectric Support: PTFE (Teflon®), precision-machined
Gasket / O-Ring: Silicone rubber (weather-sealed versions only)
Lock Washer / Nut: Stainless steel (flange and bulkhead versions)
Operating Temperature: -55℃ ~ +155℃
Storage Temperature: -65℃ ~ +165℃
Salt-Spray Resistance: ≥ 48 hours (nickel-plated); ≥ 96 hours (stainless steel)
Water Ingress: IP67 when properly mated with weather-sealed gasket (outdoor versions)
RoHS / REACH: Compliant (gold plating exemption per Annex III, 6(c))
Quality System: ISO 9001:2015 / AS9100D
Torque Specification: 1.1 N·m (8 in-lb) — always use an N-Type torque wrench. Under-torque causes intermittent contact and elevated VSWR. Over-torque strips threads or cracks dielectric.
Thread Engagement: Minimum 5 full threads engaged before applying torque.
Weather Sealing: For outdoor installations, use Coaxwave weather boots + self-amalgamating tape over the mated junction.
⚠️ 75Ω vs 50Ω Identification: 75Ω and 50Ω N-Type connectors have identical outer dimensions but different inner conductor diameters. They will mechanically mate but create a severe impedance mismatch (~1.93:1 VSWR) if mixed. Coaxwave 75Ω N connectors are clearly marked "75Ω" on the body.
⚠️ Cross-Impedance Adapter Note: 75Ω↔50Ω adapters introduce a reflection step. For precision applications, use a resistive minimum-loss pad instead of a passive mechanical adapter.
Assembly Environment / System | Recommended Model | Core Advantage | Typical Application |
|---|---|---|---|
Broadcast Studio | CW-N75-N75-MF | 75Ω, threaded secure | Video router to transmitter |
CATV Headend | CW-N75-F75-MF | N to F-Type | Amplifier to trunk |
SDI Video Router | CW-N75-BNC75-MF | N to 75Ω BNC | Studio router I/O |
Satellite Uplink | CW-N75-N75-MM | In-line barrel | Waveguide transition |
Mobile Broadcast Van | CW-N75-TNC75-MF | N to TNC | Vibration-proof link |
Transmitter Output | CW-N75-N75-MF (RA) | 90° right-angle | PA to antenna |
Test & Measurement | CW-N75-SMA-MF | N to SMA | VNA to broadcast gear |
Outdoor Tower | CW-N75-N75-FF (Bulkhead) | Weather-sealed flange | Ground to antenna |
Legacy System | CW-N75-UHF-MF | N to UHF | Older CATV bridge |
Consumer Video | CW-N75-RCA-MF | N to RCA | Studio to monitor |
Gender Sets: M-M, M-F, F-F in 75Ω N-Type
Cross-Series Adapters: 75Ω N ↔ 50Ω N / 75Ω BNC / F-Type / RCA / SMA / 75Ω TNC / UHF
Mounting Styles: Straight, 90° right-angle, 4-hole flange, bulkhead, PCB edge-mount, through-hole
Full Kit: Connector + torque wrench + weather boot + protective caps
Low-PIM Version: For broadcast transmitter applications requiring PIM < -150 dBc (special order)
Phase-Optimized: Matched-length adapter sets for phased-array or diversity systems
Right-Angle Variants: 90° for space-constrained rack installations
4-Hole Flange: For secure panel penetration in EMI-shielded enclosures
Captive Center Contact: For field-replaceable applications
Stainless Steel Body: Passivated 303/304 stainless for marine and salt-spray environments (≥ 96 hr)
Non-Magnetic Version: Beryllium copper body with gold plating for EMC chambers (special order)
Extended Temperature: PTFE dielectric rated to +200℃ for high-heat environments
100% VSWR + Hipot + IR Test: Every connector verified before shipment
Serialized Traceability: Laser-marked serial numbers on connector bodies
Rapid Prototyping: Standard 3–5 days; custom 1–2 weeks
Application Engineering: Coaxwave RF engineers provide:
Impedance transition guidance (75Ω↔50Ω) with VSWR impact analysis
Torque and installation best practices for broadcast environments
Weather-sealing recommendations for outdoor tower installations
Link-budget and power-handling calculations
Tip
"There is no perfect standard part, only the most suitable solution."
Setup: TV broadcast transmitter, 75Ω output to antenna combiner. Use CW-N75-N75-MF (straight, bulkhead-mount on transmitter front panel).
Workflow: 75Ω N male torqued to 1.1 N·m on transmitter output. Female side mates to combiner cable. Weather boot installed at outdoor transition.
Why This Connector: 75Ω system impedance matched to broadcast standard. 1.1 N·m torque ensures consistent RF contact. Bulkhead mount provides EMI-shielded panel penetration. VSWR ≤ 1.15:1 preserves transmitter efficiency.
Setup: CATV distribution amplifier, 75Ω N output to F-Type trunk line. Use CW-N75-F75-MF (straight adapter).
Workflow: 75Ω N male torqued to 1.1 N·m on amplifier. F-Type female finger-tight to trunk cable. Signal flows from amplifier to subscriber network.
Why This Connector: Bridges broadcast-grade amplifier (75Ω N) to CATV distribution (F-Type). Precision-machined transition minimizes VSWR step. Nickel-plated brass resists headend environment.
Setup: OB (outside broadcast) van, satellite uplink terminal. Vibration during transit is severe. Use CW-N75-TNC75-MF (right-angle).
Workflow: 75Ω N male torqued to 1.1 N·m on rack equipment. 75Ω TNC female threaded to mobile antenna. Right-angle clears rack rear panel.
Why This Connector: TNC threaded coupling resists vibration that would loosen BNC bayonet. Right-angle fits tight rack clearance. 75Ω impedance preserved throughout.
⚠️ 75Ω and 50Ω N-Type Look Identical — They Are NOT Interchangeable:
75Ω and 50Ω N connectors have the same outer shell dimensions but different inner conductor diameters
Mechanically they mate. Electrically they create a ~14 dB return loss (VSWR ~1.93)
Coaxwave 75Ω N connectors are permanently marked "75Ω" on the body. Verify before mating
⚠️ Torque Is 1.1 N·m — No More, No Less:
Under-torque → intermittent contact, elevated VSWR, arcing at high power
Over-torque → stripped threads, cracked PTFE dielectric, destroyed connector
Always use an N-Type torque wrench. Finger-tight is NOT sufficient
⚠️ Cross-Impedance Adapters Introduce Reflection:
75Ω↔50Ω mechanical adapters are passive impedance transitions. They are NOT transparent
For precision broadcast measurements, use a resistive minimum-loss pad (MLP) instead
⚠️ Salt-Spray Environments Require Stainless Steel:
Standard nickel-plated brass provides ~48 hr salt-spray resistance. For coastal or marine towers, specify stainless steel bodies (≥ 96 hr)
Impedance: 75Ω ±2Ω (75Ω version); 50Ω ±2Ω (50Ω version available)
Frequency Range: DC–1.5GHz (75Ω); DC–11GHz (50Ω)
VSWR: ≤ 1.15:1 (straight); ≤ 1.25:1 (right-angle)
Dielectric Withstanding: ≥ 1500V RMS
Insulation Resistance: ≥ 5000 MΩ
Temperature Range: -55℃ ~ +155℃
Torque: 1.1 N·m (always use N-Type torque wrench)
Adapter Matrix: 75Ω N ↔ 50Ω N / BNC / F-Type / RCA / SMA / TNC / UHF — any A-to-B
100% VSWR + Hipot + IR Test + Salt-Spray Verification + Serialized Traceability
Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com
⚠️ Three Reminders for 75Ω N-Type Selection:
75Ω for Broadcast, 50Ω for RF: The 75Ω version is purpose-built for video, CATV, and SDI. For cellular or general RF, use the 50Ω version (DC–11GHz).
Torque Matters — 1.1 N·m Every Time: Broadcast environments demand consistency. Under-torqued N-Type connectors are the #1 cause of elevated VSWR in studio installations.
Cross-Impedance = Reflection: If your system requires 75Ω↔50Ω transition with minimal return loss, consult Coaxwave for a resistive MLP solution rather than a mechanical adapter.
There is no perfect standard part, only the most suitable solution.
Coaxwave 75Ω N-Type RF Coaxial Connectors are engineered interconnects where brass-nickel durability, beryllium-copper-gold signal integrity, and PTFE dielectric stability deliver the most reliable 75Ω medium-power interface for broadcast, CATV, and video distribution. Every connector is VSWR-tested, hipot-verified, and salt-spray-rated with "German precision" and "French engineering logic", and ships with full serialized traceability. With support for 75Ω N same-series and cross-series adapters to 50Ω N, BNC, F-Type, RCA, SMA, TNC, and UHF, Coaxwave delivers the most suitable 75Ω N-Type solution for your exact broadcast, CATV, SDI, and satellite requirement.
Sales Email: sales@coaxial-rf.com
Company Website: