Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA CalibrationCoaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA CalibrationCoaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration
  • Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration
  • Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration
  • Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration
  • 1/3
  • Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration
  • Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration
  • Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration

Coaxwave 2.92mm Metrology-Grade Adapter | 50Ω DC-40GHz | VSWR ≤1.08 | 1/4-36 UNS Thread | 2.92mm/2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP Cross-Series | M-M M-F F-F | VNA Calibration

share
WeChat
copy Link
Facebook
X
LinkedIn
Pinterest
Whatsapp
Line
Tumblr
Coaxwave 2.92mm Metrology-Grade Adapter is the precision measurement core of the adapter matrix, 50Ω characteristic impedance, DC–40GHz. Engineered per Coaxwave proprietary Metrology-Grade Coaxial Adapter Specification: stainless steel passivated outer conductor, BeCu gold-plated center contact, PEI/ULTEM dielectric. Precision turning and electropolishing minimize interface discontinuities. 100% VNA full-band S-parameter tested, CMM interface verified, durability validated, with individual metrology test report. Covers 2.92mm same-series (M-M/M-F/F-F, straight/flange/panel-mount) and 2.92mm ↔ 2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP cross-series full gender matrix. The definitive interconnect reference for VNA metrology, calibration labs, 5G mmWave, and aerospace precision test.
Get a Quote
DetailTechnical SpecificatAssembly EnvironmentCustomization OptionApplication Scenario

Architecture — The DC–40GHz Precision Core

The 2.92mm (K-Type) interface with 1/4-36 UNS threaded coupling is mechanically compatible with SMA and 3.5mm connectors, making it the most versatile precision coaxial standard for the 18–40GHz range. Coaxwave's metrology-grade execution uses stainless steel passivated outer conductor, beryllium copper gold-plated center contact, and PEI/ULTEM dielectric support. Precision turning and electropolishing minimize interface discontinuities — the root cause of VSWR ripple at mmWave frequencies. The result: VSWR ≤1.08:1, insertion loss ≤0.05√f(GHz) dB, and repeatability better than -45dB.

All Transfer Models (complete 2.92mm adapter matrix — same-series & cross-series, all with M-M / M-F / F-F gender combinations):

No.

Model Name

Series

Gender

Body Style

Freq

Notes

1

CW-292-292-M-M-STR

2.92mm ↔ 2.92mm

Male-Male

Straight barrel

DC-40GHz

In-line, VNA port extension

2

CW-292-292-M-F-STR

2.92mm ↔ 2.92mm

Male-Female

Bullet

DC-40GHz

Minimal length, lowest reflection

3

CW-292-292-F-F-STR

2.92mm ↔ 2.92mm

Female-Female

Straight barrel

DC-40GHz

ATE fixture routing

4

CW-292-292-M-M-FLG

2.92mm ↔ 2.92mm

Male-Male

Flange mount

DC-40GHz

Panel-mounted reference

5

CW-292-292-F-F-PNL

2.92mm ↔ 2.92mm

Female-Female

Panel-mount bulkhead

DC-40GHz

Permanent installation

6

CW-292-24-M-F

2.92mm ↔ 2.4mm

Male-Female

Straight

DC-40GHz

Cross-series, 2.4mm limited to 40GHz

7

CW-292-185-M-F

2.92mm ↔ 1.85mm

Male-Female

Straight

DC-40GHz

Cross-series, 1.85mm limited to 40GHz

8

CW-292-SMA-M-F

2.92mm ↔ SMA

Male-Female

Straight

DC-26.5GHz

Cross-series, SMA limited

9

CW-292-35-M-F

2.92mm ↔ 3.5mm

Male-Female

Straight

DC-26.5GHz

Cross-series, 3.5mm limited

10

CW-292-N-M-F

2.92mm ↔ N-Type

Male-Female

Straight

DC-18GHz

Cross-series, N-Type limited

11

CW-292-SMP-M-F

2.92mm ↔ SMP

Male-Female

Straight

DC-40GHz

Board-to-board, space-constrained

12

CW-292-SSMP-M-F

2.92mm ↔ SSMP

Male-Female

Straight

DC-40GHz

Ultra-compact board interface

💡 All 12+ models share the same Coaxwave metrology-grade 2.92mm interface on the 2.92mm side. Same-series models include straight barrel, flange-mount, and panel-mount configurations. Cross-series models cover 2.4mm, 1.85mm, SMA, 3.5mm, N-Type, SMP, and SSMP — each available in M-M / M-F / F-F gender combinations. All cross-series adapters are bounded by the lower-grade interface frequency limit.

Key Performance (Coaxwave metrology-grade specification):

  • VSWR: ≤ 1.08:1 (DC–40GHz, same-series)

  • Insertion Loss: ≤ 0.05√f(GHz) dB (typical, same-series)

  • Repeatability: Better than -45 dB (connection-to-connection S21 variation at 40GHz)

  • Mating Cycles: ≥ 500 (mechanical durability verified)

Inspection: 100% VNA full-band S11/S21 sweep (DC–40GHz) + CMM interface dimensional verification + mechanical durability validation. Each unit ships with an individual metrology test report — your adapter's actual S-parameters and repeatability data. Laser-marked serial numbers guarantee full traceability.

🎯 Core Positioning: The Metrology-Grade Specification

Coaxwave 2.92mm Metrology-Grade Adapters are not standard production adapters with a "premium" label. They are designed, manufactured, and verified per the Coaxwave proprietary Metrology-Grade Coaxial Adapter Specification — a forward-designed standard that defines tighter dimensional tolerances, stricter material controls, and 100% individual verification. VSWR ≤1.08:1 is not a statistical average — it is the measured performance of your specific adapter.

⚡ Complete Adapter Matrix

Same-Series 2.92mm ↔ 2.92mm (Models 1–5):

  • Male-Male Straight (CW-292-292-M-M-STR): In-line barrel for VNA port extension or joining two 2.92mm female cables. Primary choice for national metrology labs.

  • Male-Female Bullet (CW-292-292-M-F-STR): Minimal-length gender-changer. Lowest reflection configuration for direct DUT-to-cable connection.

  • Female-Female Straight (CW-292-292-F-F-STR): In-line barrel for joining two 2.92mm male cables. Used in ATE fixture routing.

  • Male-Male Flange Mount (CW-292-292-M-M-FLG): Panel-mounted reference adapter for permanent calibration lab installation.

  • Female-Female Panel-Mount (CW-292-292-F-F-PNL): Bulkhead feedthrough for test chamber wall penetration.

Cross-Series 2.92mm ↔ 2.4mm / 1.85mm (Models 6–7):

  • Electrically bounded to 40GHz (both sides rated to 40GHz through the 2.92mm side). 2.4mm and 1.85mm use M7×0.75 thread — not mechanically compatible with 2.92mm's 1/4-36 UNS. The adapter provides a controlled impedance transition between thread standards.

Cross-Series 2.92mm ↔ SMA / 3.5mm (Models 8–9):

  • Electrically bounded to 26.5GHz (SMA/3.5mm limit). Both use 1/4-36 UNS thread — mechanically compatible with 2.92mm. Ideal for bridging 2.92mm instrumentation to legacy SMA/3.5mm DUTs.

Cross-Series 2.92mm ↔ N-Type (Model 10):

  • Electrically bounded to 18GHz (N-Type limit). N-Type uses 1/4-28 UNS thread. Provides a robust bridge from precision 2.92mm instrumentation to general-purpose N-Type test equipment.

Cross-Series 2.92mm ↔ SMP / SSMP (Models 11–12):

  • Electrically DC–40GHz. SMP/SSMP are push-on interfaces for board-to-board applications. Enables connection from 2.92mm VNA ports to SMP/SSMP-equipped phased-array modules or MMIC test boards.

🛡️ Coaxwave Metrology Barrier

Every 2.92mm Metrology-Grade Adapter undergoes four mandatory 100% controls:

  1. 100% VNA Full-Band S-Parameter Sweep: S11 and S21 measured from DC to 40GHz. VSWR ≤1.08:1 verified per unit on same-series models.

  2. CMM Interface Dimensional Inspection: Outer conductor inner diameter, center conductor outer diameter, and position tolerance checked per Coaxwave proprietary specification (tighter than industry baseline).

  3. Repeatability Verification: Connection-disconnection cycle test confirms S21 variation better than -45dB at 40GHz.

  4. Mechanical Durability Validation: Mating cycle test confirms ≥500 cycles without performance degradation.

Each unit ships with an individual metrology test report — your adapter's actual S-parameters and repeatability data. Laser-marked serial numbers on every adapter guarantee full traceability. The Coaxwave torque wrench (1/4-36 UNS, 0.9 N·m) is included with every adapter.


Electrical Performance

  • Frequency Range: DC – 40 GHz (same-series); cross-series limited by lower-grade interface

  • Impedance: 50Ω ±0.5%

  • VSWR: ≤ 1.08:1 (same-series, DC–40GHz)

  • Insertion Loss: ≤ 0.05√f(GHz) dB (typical, same-series)

  • Repeatability: Better than -45 dB (connection-to-connection S21 variation at 40GHz)

  • Isolation: ≥ 100 dB (connector port to outer conductor)

Mechanical Performance

  • Interface Standard: MIL-STD-348 (2.92mm/K-Type)

  • Coupling Thread: 1/4-36 UNS (unified special thread)

  • Coupling Nut Torque: 0.9 N·m (8 in-lbs) — use included Coaxwave 2.92mm torque wrench

  • Mating Cycles: ≥ 500 (mechanical durability verified)

  • Engagement: Minimum 5-thread full engagement before torque application

Materials & Structure

  • Outer Conductor: Passivated stainless steel (SUS303)

  • Center Contact: Beryllium copper, gold-plated over nickel underplate

  • Dielectric: PEI (Polyetherimide) / ULTEM composite support

  • Plating Thickness: Gold ≥ 0.00005" over nickel underplate

  • Surface Finish: Electropolished outer conductor inner surface; center contact super-finished to minimize contact resistance

  • Dimensional Control: Per Coaxwave proprietary Metrology-Grade Coaxial Adapter Specification (Class A+)

Environment & Compliance

  • Operating Temperature: -55℃ ~ +125℃

  • Storage Temperature: -65℃ ~ +150℃

  • Humidity: 95% RH, 240 hours (MIL-STD-202, Method 106)

  • Vibration: MIL-STD-202, Method 204, Condition D

  • Shock: MIL-STD-202, Method 213, Condition B

  • RoHS / REACH: Compliant

  • Quality System: ISO 9001:2015 / AS9100D

Adaptation & Installation

  • Thread Engagement:

    • Always ensure minimum 5-thread engagement before applying torque

    • Hand-start the 1/4-36 UNS thread — never force

    • If resistance is felt before 5 threads, stop and inspect for cross-threading


  • Torque Application:

    • Use ONLY the included Coaxwave 2.92mm torque wrench (0.9 N·m / 8 in-lbs)

    • ⚠️ CRITICAL: 1/4-36 UNS is mechanically compatible with SMA and 3.5mm wrenches — however, always use the Coaxwave-supplied wrench for calibration traceability

    • ⚠️ 2.4mm/1.85mm use M7×0.75 metric thread — NOT compatible with 1/4-36 UNS. Never force a 2.4mm wrench onto a 2.92mm adapter.


  • Mating Hygiene:

    • Inspect center contact and dielectric for debris before every connection

    • Use compressed air or lint-free swab if contamination is visible

    • Cap both ends when not in use



Assembly Environment / System

Recommended Model

Core Advantage

Typical Application

VNA Calibration Kit

CW-292-292-M-F-STR

Male-female bullet, VSWR ≤1.08

Calibration standards interconnection

National Metrology Lab

CW-292-292-M-M-FLG

Flange-mount, repeatability <-45dB

Permanent calibration reference

5G mmWave Test

CW-292-292-F-F-STR

Female-female, low loss

DUT-to-cable, DC-40GHz

Phased-Array Module Test

CW-292-SMP-M-F

2.92mm-to-SMP

VNA to SMP board interface

SatCom Transceiver

CW-292-SMA-M-F

2.92mm-to-SMA

Legacy SMA equipment bridge

Defense EW Receiver

CW-292-35-M-M

2.92mm-to-3.5mm

Signal intelligence, 26.5GHz

Semiconductor ATE

CW-292-SSMP-M-F

2.92mm-to-SSMP

MMIC wafer probe to 2.92mm test set

Production HPA Test

CW-292-N-M-M

2.92mm-to-N-Type

Amplifier ATE, 18GHz

University Research

CW-292-292-M-M-STR

Male-male, metrology grade

Educational, DC-40GHz

Field Service Kit

CW-292-292-M-F-STR

Male-female bullet

Portable mmWave test set

Standard Matrix & Extensions

  • 12+ Standard Models: 2.92mm same-series (straight/flange/panel-mount, M-M/M-F/F-F) + cross-series to 2.4mm, 1.85mm, SMA, 3.5mm, N-Type, SMP, SSMP

  • Full Kit: Adapter + protective caps + Coaxwave torque wrench (1/4-36 UNS, 0.9 N·m) + individual metrology test report

⚡ Electrical Performance Customization

  • Ultra-Low VSWR Version: VSWR ≤ 1.05:1 (extended selection + individual optimization, for national metrology use)

  • Phase-Matched Pairs: Two adapters matched to ±1.5° at 40GHz for differential systems

Structural Customization

  • Extended Length Barrel: For applications requiring specific spacing between mating faces

  • Keyed Coupling Nut: Prevents mis-mating in multi-port arrays

  • Custom Flange Pattern: Per customer drawing for panel-mount installations

️ Material & Environmental Customization

  • Non-Magnetic Version: For EMC chambers and quantum mmWave test

  • Hermetically Sealed: For pressurized systems

  • Extended Temperature: For thermal chamber calibration (-55℃ to +125℃)

Service & Support

  • 100% VNA Full-Band Characterization: Every adapter measured DC–40GHz (same-series)

  • Individual Metrology Test Report: Actual S-parameters and repeatability data per unit

  • SN Traceability: Laser-marked unique serial numbers on every adapter

  • Rapid Prototyping: Standard models 2-3 week shipment; custom 4-6 weeks

  • Application Engineering: Coaxwave RF engineers provide:

    • 2.92mm torque and repeatability best practices

    • Cross-series frequency boundary guidance

    • VNA calibration plane management

    • SMP/SSMP board interface layout support


Tip

"There is no perfect standard part, only the most suitable solution."

VNA Calibration — National Metrology (DC–40GHz)

  • Setup: Mount CW-292-292-M-F-STR between VNA test port (2.92mm female) and calibration kit or DUT cable.

  • Workflow: Hand-start 1/4-36 UNS thread both ends. Torque each to 0.9 N·m with included Coaxwave wrench. Run VNA sweep DC–40GHz.

  • Why This Adapter: VSWR ≤1.08:1 and repeatability better than -45dB ensure the adapter contributes <0.05dB measurement uncertainty. At 40GHz, this separates valid calibrations from calibration errors.

Phased-Array Module Test — 2.92mm to SMP

  • Setup: VNA has 2.92mm ports. Phased-array module uses SMP board connectors. Use CW-292-SMP-M-F (2.92mm male → SMP female).

  • Workflow: 2.92mm side torqued to 0.9 N·m. SMP side push-on engagement (no torque required). Align carefully to avoid SMP socket damage.

  • Why This Adapter: Bridges precision 2.92mm VNA to space-constrained SMP board interface. DC–40GHz coverage matches the module's operating band.

️ SatCom Production Test — 2.92mm to SMA Legacy Bridge

  • Setup: New VNA has 2.92mm ports. Production test cables are SMA. Use CW-292-SMA-M-F (2.92mm male → SMA female).

  • Workflow: 2.92mm side torqued to 0.9 N·m. SMA side torqued to 0.9 N·m with SMA wrench. Quick connect/disconnect for production line.

  • Why This Adapter: Extends new 2.92mm instrumentation to legacy SMA infrastructure. Electrically limited to 26.5GHz — sufficient for many SatCom IF chains.

⚠️ Usage Red Lines

  • ⚠️ 2.92mm Torque: 0.9 N·m (8 in-lbs) — Use ONLY the Included Coaxwave Wrench:

    • 1/4-36 UNS thread is mechanically compatible with SMA and 3.5mm wrenches — however, always use the included Coaxwave wrench for calibration traceability

    • 2.4mm/1.85mm use M7×0.75 metric thread — NEVER attempt to use a 2.4mm wrench on a 2.92mm adapter


  • ⚠️ Cross-Series Frequency Is Bounded by the Lower-Grade Interface:

    • 2.92mm ↔ 2.4mm / 1.85mm: limited to 40GHz (2.92mm side is the limiting factor)

    • 2.92mm ↔ SMA / 3.5mm: limited to 26.5GHz (SMA/3.5mm rating)

    • 2.92mm ↔ N-Type: limited to 18GHz

    • Know your frequency boundary before selecting the cross-series model


  • ⚠️ SMP/SSMP Are Push-On Interfaces — No Torque:

    • SMP/SSMP connectors use snap-on engagement, not threaded coupling

    • Align the bullet with the socket before applying pressure — never force at an angle

    • Misalignment will damage the SMP/SSMP socket beyond repair


  • ⚠️ Minimum 5-Thread Engagement Required:

    • The 1/4-36 UNS thread requires at least 5 full threads engaged before torque application

    • Hand-start and verify full engagement — never force



Coaxwave 2.92mm Metrology-Grade Adapter · Delivery Commitment

  • Frequency: DC – 40 GHz (same-series)

  • Impedance: 50Ω ±0.5%

  • VSWR: ≤ 1.08:1 (factory, per unit, Coaxwave metrology-grade specification)

  • Insertion Loss: ≤ 0.05√f(GHz) dB (typical, same-series)

  • Repeatability: Better than -45 dB (connection-to-connection at 40GHz)

  • Mating Cycles: ≥ 500

  • Adapter Matrix: 2.92mm same-series (straight/flange/panel-mount, M-M/M-F/F-F) + cross-series to 2.4mm/1.85mm/SMA/3.5mm/N/SMP/SSMP = 12+ standard models

  • Interface: MIL-STD-348 (2.92mm/K-Type), 1/4-36 UNS thread

  • Materials: Stainless-steel passivated body + BeCu gold-plated center contact + PEI/ULTEM dielectric

  • 100% VNA Full-Band S-Parameter Test + CMM Dimensional Verification + Repeatability Verification + Individual Metrology Test Report + SN Traceability

  • Included: Coaxwave torque wrench (torque wrench included with every adapter)

  • Quality System: ISO 9001 / AS9100D | sales@coaxial-rf.com

⚠️ Three Reminders for 2.92mm Metrology-Grade Selection:

  1. VSWR ≤1.08:1 Is Measured Per Unit, Not Per Batch: Every adapter ships with its own metrology test report showing actual S-parameters and repeatability. Your adapter's performance is documented — not estimated from a batch average.

  2. The Included Torque Wrench Is Part of the Specification: The <-45dB repeatability claim assumes 0.9 N·m torque on every connection. Using any other wrench voids the repeatability guarantee. Always use the included Coaxwave torque wrench.

  3. 2.92mm ↔ SMA/3.5mm Are Mechanically Compatible — But Verify Frequency Need: SMA and 3.5mm share the 1/4-36 UNS thread and can be directly mated to 2.92mm without an adapter. However, the measurement is then limited to 26.5GHz. For any measurement above 26.5GHz, use a 2.92mm-to-2.92mm connection.


There is no perfect standard part, only the most suitable solution.

Coaxwave 2.92mm Metrology-Grade Adapters are not merely interconnects; they are the engineered assurance that your VNA calibration reflects the DUT — not the adapter. We control every micron of dimensional variation, verify every S-parameter and repeatability data point with "German precision" and "French engineering logic", and deliver with full SN traceability and a calibrated torque wrench. With twelve standard models covering every same-series configuration and cross-series need, 100% VNA certification, and a commitment to metrology-grade performance, Coaxwave delivers the most suitable 2.92mm adapter for your exact VNA calibration, 5G mmWave, aerospace, and defense requirement.